Path: Top > Tugas Akhir - D3 > 2017 > Jurusan Teknik Kimia > Program Studi Teknik Kimia > 2021

Pengaruh Suhu Operasi Pada Kinerja Solid Oxide Fuel Cell (SOFC) dengan Bahan Bakar Hidrogen

The Influence Of Operating Temperature on Solid Oxide Fuel Cell (SOFC) with Hydrogen Fuel

Tugas Akhir, 001 / 2021 / TKI
Undergraduate Theses from JBPTPPOLBAN / 2024-01-09 11:32:49
Oleh : Agisni Nursalma Atsilah 181411001 & Annisa Nurleli - 181411006 (annisa.nurleli.tki18@polban.ac.id)
Dibuat : 2024-01-09, dengan 4 file

Keyword : Influence, Operating Temperature, Solid Oxide Fuel Cell, SOFC), Hydrogen Fuel
Subjek : Pengaruh, Suhu Operasi, Kinerja, Solid Oxide Fuel Cell, SOFC, Bahan Bakar Hidrogen

Solid oxide fuel cell adalah perangkat yang mengkonversi energi kimia dalam bahan bakar menjadi energi listrik yang sedang banyak dikembangkan karena ramah lingkungan. Penelitian ini difokuskan pada pengujian kinerja SOFC dalam menghasilkan arus listrik. Tahapan pada penelitian ini dimulai dari persiapan sel, perangkaian sistem, dan uji kinerja SOFC. Pengujian dilakukan pada dua jenis SOFC dengan berbagai suhu dan laju alir menggunakan bahan bakar hidrogen. Parameter dari pengujian ini terdiri dari open circuit voltage, rapat arus, dan area specific resistance. Pengujian dimulai dari suhu 800°C, 750°C, 700°C, lalu 650°C dengan variasi laju alir H2:He pada setiap suhu yaitu 70:35, 70:0, dan 140:0 ml/menit. Hasil pengujian ini menyatakan bahwa semakin tinggi suhu operasi, maka nilai arus litrik yang dihasilkan akan semakin besar. Hasil kinerja SOFC yang terbaik terjadi pada suhu 800°C dengan laju alir H2:He 140:0 ml/menit, ChFC4-LSCF 6D menghasilkan OCV 1083 mV dan ChFC6-LSM 6D menghasilkan OCV 1061 mV. Pada tegangan 0,7 Volt ChFC4-LSCF 6D menghasilkan rapat arus 357 mA/cm2 dengan nilai ASR 1,074 Ω.cm2 dan ChFC6-LSM 6D menghasilkan rapat arus 446 mA/cm2 dengan nilai ASR 0,811 Ω.cm2. Hasil ini menunjukkan bahwa rangkaian pengujian SOFC pada penelitian ini mampu mengukur kinerja SOFC dengan baik. Kata kunci: Solid Oxide Fuel Cell, Open Circuit Voltage, i-v curve, area specific resistance

Deskripsi Alternatif :

Solid oxide fuel cell is a device that convert chemical fuel to electrical power which is being developed because it is environmentally friendly. This research is focused on performance testing of SOFC in generating electricity. The stages in this study include cell preparation, system assembly, and SOFC performance testing. The test was accomplished on two types of SOFC with various temperature and flow rates using hydrogen as fuel. Parameters used in this test consist of open circuit voltage, current density, and area specific resistance. The tests were carried out at 800°C, 750°C, 700°C, then 650°C with various flowrate of H2:He for each temperature i.e. 70:35, 70:0, and 140:0 ml/minute. The results shows that the higher the temperature, the more electricity will be generated. The best performance was obtained at 800°C and 140 ml/minute H2 flowrate. At 0,7 Volt SOFC-ChFC4-LSCF-6D produced a current density of 357 mA/cm2 with ASR value at 1,074 Ω.cm2 and SOFC-ChFC6-LSM produced 446 mA/cm2 with ASR value at 0,811 Ω.cm2. These results indicate that the two SOFCs and the SOFC performance Test-Rig used in this study perform well. Keywords: Solid Oxide Fuel Cell, Open Circuit Voltage, i-v curve, area specific resistance

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakErlin Arvelina
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorerlin.arvelina@polban.ac.id
E-mail CKOerlin.arvelina@polban.ac.id

Print ...

Kontributor...

  • Pembimbing 1: Ir. Retno Indarti, M.T.




    Pembimbing 2: Lina Troskialina, B.Sc., M.Sc., Ph.D., Editor: Muhammad Abdillah Islamy, S.Pd