Path: Top > Tugas Akhir - D3 > Jurusan Teknik Refrigerasi dan Tata Udara > Program Studi Teknik Refrigerasi dan Tata Udara > 2016

Pengaruh Penggunaan Liquid Suction Heat Exchanger Pada Kinerja Ac Split Kapasitas 1 Pk

The Influences of The Used of Liquid Suction Heat Exchanger in Split AC with 1 PK in Capacity

Tugas Akhir, 016 / 2016 / RTU
Undergraduate Theses from JBPTPPOLBAN / 2017-09-04 10:17:32
Oleh : Auliya Fathiyyah - 131611038 (auliyafathiyyah@gmail.com)
Dibuat : 2017-09-04, dengan 4 file

Keyword : Split AC, Liquid Suction Heat Exchanger,The Improvement of System Performace
Subjek : AC Split, Liquid Suction Heat Exchanger, Peningkatan Kinerja Sistem

AC Split merupakan salah satu mesin tata udara yang mampu mengkondisikan temperatur ruangan sesuai dengan yang kita inginkan, terutama dalam mengkondisikan temperatur ruangan menjadi lebih rendah dibanding temperatur lingkungan sekitar. Banyak cara dilakukan untuk meningkatkan kinerja sistem. Dalam hal ini, liquid suction heat exchanger diaplikasikan untuk meningkatkan kinerja sistem dengan memanfaatkan refrigeran sisi hisap yang dingin untuk mendinginkan refrigeran sisi cair yang panas. Hal tersebut menyebabkan peningkatan derajat subcooled. Analisis dilakukan dengan melakukan pengambilan data pada sistem tanpa LSHX dan sistem dengan LSHX menggunakan parameter seperti tekanan discharge, tekanan suction, temperatur discharge, temperatur suction, temperatur inlet kapiler, temperatur lingkungan, arus kerja, dan tegangan listrik. Kemudian dilakukan pengolahan data hingga didapat kesimpulan berupa hasil kinerja sistem. Dari hasil analisis diperoleh nilai COPaktual rata-rata untuk sistem dengan LSHX adalah sebesar 5,02 sedangkan sistem tanpa LSHX adalah sebesar 4,5 lalu EERrata-rata untuk sistem dengan LSHX adalah sebesar 9,28sedangkan sistem tanpa LSHX adalah sebesar 3,89 dan efisiensi rata-rata untuk sistem dengan LSHX adalah sebesar 71% sedangkan sistem tanpa LSHX adalah sebesar 68%. Sedangkan untuk kapasitas pendinginan sisi udara untuk sistem dengan LSHX yaitu menyerap kalor udara sebesar 1,64 kW sedangkan sistem tanpa LSHX adalah sebesar 0,72 kW. Untuk konsumsi daya listrik sistem dengan LSHX rata-rata sebesar 0,60 kWh sedangkan sistem tanpa LSHX adalah sebesar 0,63 kWh. Jadi penggunaan LSHX pada sistem AC Split lebih baik dalam segi kinerja sistem apabila dibandingkan dengan sistem AC Split tanpa LSHX. Kata kunci : AC Split, Liquid Suction Heat Exchanger, Peningkatan Kinerja Sistem

Deskripsi Alternatif :

Split AC is the machine that can customize room temperature according to temperature we need, mainly forconditioning room temperature become lower than an ambient temperature. A lot of way done to improve the performances of system. In that case, liquid suction heat exchangerapplied to improve the performaces of system by making use of cold suction refrigerant to cool the sides of hot liquid refrigerant. It also results in an increase of the degree of subcool. The analysis is done by taking a data from the system without LSHX and the system with LSHX using parameter such as discharge pressure, suction pressure, discharge temperature, suction temperature, capillary inlet temperature, ambient temperature, work current, and electricity voltage. Then do the processing data to gain the conclusion in the form of results of system performace. The results of analysis is the average of COPactual for the system with LSHX is 5,02, while the system without LSHX is 4,5 then the average of EERfor the system with LSHX is 9,28, while the system without LSHX is 3,89 and the average of efficiency system with LSHX is 71% while the system without LSHX is 68%. The cooling capacity for the air side of the system with LSHX absorb heat of 1,64 kW, while the system without LSHX is of 0,72 kW. The electrical power consumptionfor the system with LSHX is 0,60 kWh while the system without LSHX is 0,63 kWh. So, the used of liquid suction heat exchangerin Split ACis better in the system performace compared with Split AC system without LSHX. Key Words : Split AC, Liquid Suction Heat Exchanger,The Improvement of System Performace

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakErlin Arvelina
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorerlin.arvelina@polban.ac.id
E-mail CKOerlin.arvelina@polban.ac.id

Print ...

Kontributor...

  • Pembimbing 1 : M. Nuryadi, ST., M.Eng ; Pembimbing 2 : Tandi Sutandi, SST., MT , Editor: Muhammad Abdillah Islamy, S.Pd

Download...