Path: Top > Tugas Akhir - D3 > Jurusan Teknik Elektro > Program Studi Teknik Listrik > 2013
Motor Induksi Slip Ring 1000 Watt, 220 Volt, 50 Hz sebagai Generator Eksitasi Sendiri dengan Kapasitansi Stator Luar
Slip Ring Induction Motor 1000 Watt, 220 Volt, 50 Hz as Generator Self Excitation with Outside Stator Capacitance
Tugas Akhir, 067 / 2013 / TLIUndergraduate Theses from JBPTPPOLBAN / 2017-05-17 15:42:56
Oleh : Azmi Nur Fauzan - 101321005 (azmi.anf@gmail.com)
Dibuat : 2017-05-17, dengan 4 file
Keyword : motor induksi slip ring, motor induksi sebagai generator, thyristor switched capacitor (TSC), zero crossing detector, optocoupler
Subjek : induction motor slip ring, induction motor as generator, thyristor switched capacitor (TSC), zero crossing detector, optocoupler
Bila slip dibuat negatif atau dengan kata lain kecepatan berputar rotor (Nr) dibuat lebih besar dari kecepatan sinkron (Ns), maka mesin akan berfungsi sebagai generator. Motor induksi yang diubah menjadi generator induksi adalah motor induksi slip ring 1000Watt, 220Volt, 50Hz yang dihubung segitiga. Beban yang digunakan adalah beban resistif dan induktif yang dihubung segitiga. Metode yang digunakan adalah metode thyristor switched capacitor (TSC) dengan pengaturan sudut penyulutan. Metode tersebut dilengkapi dengan zero crossing detector sebagai pendeteksi titik nol dan optocoupler sebagai isolasi. Kapasitor yang nilainya tetap (30μF) dapat dibebani mulai beban nol hingga 550 Watt. Selanjutnya menggunakan penambahan kapasitor sebesar 4μF hingga beban mencapai 800 Watt. Dikarenakan adanya arus kejut yang menyebabkan triac rusak, sehingga dilakukan simulasi pengendali menggunakan sumber PLN dan beban lampu. Hasilnya, kapasitor tambahan aktif pada keadaan dibawah regulasi tegangan. Kata kunci: motor induksi slip ring, motor induksi sebagai generator, thyristor switched capacitor (TSC), zero crossing detector, optocoupler.
Deskripsi Alternatif :When slip is made negative or in other words rotating rotor speed (Nr) is made larger than the synchronous speed (Ns), then the machine will function as a generator. Induction motor which converted to an induction generator is slip ring induction motor 1000Watt, 220Volt, 50Hz which linked triangles. Load used is resistive and inductive loads which linked triangles. The method used is the method of thyristor switched capacitor (TSC) with the ignition angle settings. The method comes with a zero crossing detector for detecting the zero point and optocoupler as isolator. Fixed value capacitor (30μF) can be loaded starting from zero to 550 Watt. Further use capacitors 4μF addition to the load to 800 Watt. Due to the current shock which causes damaged triac, so the simulation of control is done using source PLN and bulb as load. As a result, an additional capacitor active when voltage in under regulation. Keywords: induction motor slip ring, induction motor as generator, thyristor switched capacitor (TSC), zero crossing detector, optocoupler.
Beri Komentar ?#(0) | Bookmark
Properti | Nilai Properti |
---|---|
ID Publisher | JBPTPPOLBAN |
Organisasi | |
Nama Kontak | Erlin Arvelina |
Alamat | Jl. Trsn. Gegerkalong Hilir Ds. Ciwaruga |
Kota | Bandung |
Daerah | Jawa Barat |
Negara | Indonesia |
Telepon | 022 201 3789 ext. 168, 169, 239 |
Fax | 022 201 3889 |
E-mail Administrator | erlin.arvelina@polban.ac.id |
E-mail CKO | erlin.arvelina@polban.ac.id |
Print ...
Kontributor...
- Pembimbing 1: Drs. Sofian Yahya, S.ST., M.T.
Pembimbing 2: Ir. Dedi Nono Suharno, M.T., Editor: Erlin Arvelina
Download...
File : DAFTAR - 101321005.pdf
(474904 bytes)
File : BAB 1 - 101321005.pdf
(317258 bytes)
File : BAB 2 - 101321005.pdf
(749935 bytes)
File : BAB 5 - 101321005.pdf
(225258 bytes)