Path: Top > Tugas Akhir - D3 > Jurusan Teknik Refrigerasi dan Tata Udara > Program Studi Teknik Refrigerasi dan Tata Udara > 2013

Rancang Bangun Training Unit Air Conditioner Berteknologi Inverter

Design Training Unit Air Conditioner Using Inverter Technology

Tugas Akhir, 068 / 2013 / RTU
Undergraduate Theses from JBPTPPOLBAN / 2017-04-25 11:14:56
Oleh : Brian Ramadhan Andriana - 101611040 (bryan_redland@yahoo.co.id)
Dibuat : 2017-04-25, dengan 4 file

Keyword : Air Conditioner Inverter, Air Conditioner non Inverter, performansi sistem
Subjek : Air Conditioner Inverter, Air Conditioner non Inverter,performance of system

Air Conditioner merupakan salah satu alat yang membutuhkan daya litrik yang besar.O lehkarenaitu, diciptakanlah sebuah teknologi inverter. Teknologi inverter ini berfungsi untuk mengurangi pemakaian daya listrik. Pada tugas akhir ini menginstalasi sistem Air Conditioner dengan menggunakan teknologi inverter, dengan temperatur settingan 16 ºC di dalam ruangan yang diberikan beban heater dan tidak diberikan beban heater. Serta melakukan pengolahan data untuk mengetahui performansi dari sistem tersebut. Dari hasil pengolahan data, didapat nilai efisiensi sistem AC Inverter yang diberikan beban heater sebesar 76,75% dan COP sistem sebesar 5,06. Sedangkan nilai efisiensi AC non Inverter yang diberikan beban heater sebesar 78,51 % dan COP sistem sebesar 4,53. Nilai efisiensi sistem AC Inverter yang tidak diberikan beban heater sebesar 79,26% dan COP sistem sebesar 5,76. Sedangkan nilai efisiensi AC non Inverter yang tidak diberikan beban heater sebesar73,48 % dan COP sistem sebesar 4,24 Kata kunci: Air Conditioner Inverter, Air Conditioner non Inverter, performansi sistem.

Deskripsi Alternatif :

Air Conditioner is device which need big power consumption. So, the inverter technology created. The Inverter technology has function for decrease power consumption. In this final project done installed air conditioner system using inverter technology, with temperature setting in room conditioned 16 ºC which have heater load and non-heater load. With data processing to now performance from that system. From data processing, have a value of AC Inverter efficiency use heater load 76,75% and COP 5,06. Whereas AC non Inverter efficiency value use heater load 78,51% and COP 4,53.Value of AC Inverter efficiency use non-heater load 79,26 % and COP 5,76. Whereas AC non Inverter efficiency value use non-heater load 73,48% and COP 4,24. Keyword: Air Conditioner Inverter, Air Conditioner non Inverter,performance of system.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakErlin Arvelina
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorerlin.arvelina@polban.ac.id
E-mail CKOerlin.arvelina@polban.ac.id

Print ...

Kontributor...

  • Pembimbing 1: Ade Suryatman Margana, S.T., M.Eng.

    Pembimbing 2: Luga Martin Simbolon, S.T., M.Sc., Editor: Erlin Arvelina