Perancangan Sea Water Reverse Osmosis Menggunakan Membran Diameter 16 Inci Pada Sistem Pengolahan Air Di PLTU
The Design Of Sea Water Reverse Osmosis Using Membrane Diameter 16 Inch In Water Processing System In PLTU
Skripsi, 005 / 2018 / TPTLUndergraduate Theses from JBPTPPOLBAN / 2018-10-01 10:57:36
Oleh : Dani Ramdani - 141724004 (ramdaniputri06@gmail.com)
Dibuat : 2018-10-01, dengan 4 file
Keyword : sea water, osmosis, membrane, water process, PLTU
Subjek : sea water, osmosis, membrane, water process, PLTU
Air merupakan media yang sangat diperlukan pada Pembangkit Listrik Tenaga Uap sebagai sarana untuk memenuhi kebutuhan seperti pembangkitan uap, penggunaan kebutuhan sehari-hari pegawai, pasokan air untuk pemadam kebakaran, pengangkutan abu sisa pembakaran, dan maintenance. Pada umumnya air sumber yang digunakan PLTU untuk memenuhi kebutuhannya berasal dari air laut, maka perlu diolah terlebih dahulu agar kualitas air yang digunakan sesuai dengan standar air pembangkit. Proses pengolahan air laut memiliki banyak cara salah satunya menggunakan teknologi terbaru membran reverse osmosis yang terbukti efisien, ramah lingkungan serta hemat biaya dan dapat merejeksi TDS (Total Dissolved solid) air laut sampai 99,8%. Membran reverse osmosis tersusun atas polymide yang dikumpulan sehingga membentuk elemen flat sheet yang konfigurasikan menjadi spiral wound. Dalam perkembangan teknologi membran reverse osmosis saat ini telah hadir membran keluaran terbaru berdiamter 16 in yang terbukti dapat lebih menghemat biaya karena instalasi yang relatif sedikit, produksi air bisa lebih banyak dan biaya produksi air menjadi lebih murah serta dapat merjeksi kandungan TDS sampai 99,6%. Karena pengolahan untuk air laut maka tipe membran yang digunakan yaitu SWRO ( Sea Water Reverse Osmosis) karena kualitas air laut memiliki kandungan TDS >35000 mg/L. Hasil rancangan sea water reverse osmosis untuk memenuhi kebutuhan air pada pembangkit berkapasitas 2 x 660 MW. Kata kunci: sea water, osmosis, membrane, water process, PLTU.
Deskripsi Alternatif :Water is an indispensable medium for Steam Power Plant as a means to meet such needs as steam generators, daily employee use, water supply for fire extinguishers, ash burning, and maintenance. In general, air source which is a PLTU to meet its needs from sea water, need to be processed first so that air quality in accordance with standard air generator. Seawater processing has many ways one of which uses reverse osmosis membrane technology that is proven to be efficient, environmentally friendly and cost-effective and can reject TDS (Total Dissolved solid) sea water up to 99.8%. The reverse osmosis membrane consists of collected polymides forming flat sheet elements that are configured to be spiral wounds. In the development of current reverse osmosis membrane technology has come the latest update membrane 16 which proves to be more efficient because the installation is relatively small, water production will be more and the cost of water production becomes cheaper also can inject TDS content upwards. to 99.6%. Due to seawater treatment, this type of membrane is SWRO (Sea Water Reverse Osmosis) because seawater quality has TDS> 35000 mg / L. The result of the seawater reverse osmosis design is to meet the air requirement at 2 x 660 MW of power plant. Keywords: sea water, osmosis, membrane, water process, PLTU
Beri Komentar ?#(0) | Bookmark
Properti | Nilai Properti |
---|---|
ID Publisher | JBPTPPOLBAN |
Organisasi | |
Nama Kontak | Erlin Arvelina |
Alamat | Jl. Trsn. Gegerkalong Hilir Ds. Ciwaruga |
Kota | Bandung |
Daerah | Jawa Barat |
Negara | Indonesia |
Telepon | 022 201 3789 ext. 168, 169, 239 |
Fax | 022 201 3889 |
E-mail Administrator | erlin.arvelina@polban.ac.id |
E-mail CKO | erlin.arvelina@polban.ac.id |
Print ...
Kontributor...
- Pembimbing: Dra. Tina Mulya Gantina, M.T., Editor: Erlin Arvelina
Download...
File : KELENGKAPAN SKRIPSI - 141724004.pdf
(939218 bytes)
File : BAB 1 - 141724004.pdf
(566723 bytes)
File : BAB 2 - 141724004.pdf
(1466061 bytes)
File : BAB 5 - 141724004.pdf
(477848 bytes)