Path: Top > Tugas Akhir - D3 > Jurusan Teknik Elektro > Program Studi Teknik Listrik > 2012

RANCANG BANGUN MODUL PRAKTIKUM PROTEKSI JARINGAN DISTRIBUSI TERHADAP GANGGUAN HUBUNG SINGKAT ANTAR FASA MENGGUNAKAN

DESIGN PROTECTION PRACTICE MODULE OF ELECTRIC POWER DISTRIBUTION SYSTEM TO INTER PHASE SHORT CIRCUIT

Tugas Akhir, 007 / 2012 / TLI
Undergraduate Theses from JBPTPPOLBAN / 2015-11-18 09:21:47
Oleh : Dede Hidayat - 091321008
Dibuat : 2013-04-19, dengan 4 file

Keyword : Gangguan hubung singkat antar fasa, OCR, setelan
Subjek : Inter phase short circuit interruption, OCR, setting

Sistem proteksi sangat dibutuhkan untuk meningkatkan TMP (Tingkat Mutu Pelayanan) sehingga dapat mencegah/membatasi kerusakan peralatan akibat gangguan, dan kelangsungan penyaluran tenaga listrik dapat dipertahankan. Gangguan yang sering terjadi pada sistem tenaga listrik adalah gangguan hubung singkat antar fasa. Pengaman yang digunakan untuk mengatasi gangguan hubung singkat adalah rele arus lebih. Oleh karena itu, diperlukan pengujian pada modul hubung singkat untuk mengetahui nilai arus hubung singkat yang tepat untuk mendapat gambaran mengenai situasi arus hubung singkat khususnya dalam kaitannya dengan setelan alat-alat pengaman seperti OCR. Pada Proyek Akhir ini akan dilakukan pengujian arus hubung singkat yang diperlukan untuk menentukan setelan OCR, sehingga bila terjadi gangguan hubung singkat antar fasa, peralatan pengaman akan bekerja mengamankan bagian sistem yang terganggu sesuai yang diharapkan. Kata kunci: Gangguan hubung singkat antar fasa, OCR, setelan

Deskripsi Alternatif :

Protection system is needed to improve the TMP (Service Quality Level) so as to prevent / limit damage to equipment due to interference, and continuity of electrical power supply can be maintained. Disorders that frequently occur in power systems are a Inter phase short circuit nuisance. Safety is used to overcome the interference of short circuit is over-current relay. Therefore, the required testing on the module short circuit to determine the short-circuit current value of the right to get an idea of the short circuit current situation particularly in relation to setting safety tools such as OCR. In this Final project will be a short-circuit current testing is needed to determine the setting OCR, so that in case of inter phase short circuit interruption, safety equipment will work to secure the affected system as expected. Keywords : Inter phase short circuit interruption, OCR, setting.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakErlin Arvelina
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorerlin.arvelina@polban.ac.id
E-mail CKOerlin.arvelina@polban.ac.id

Print ...

Kontributor...

  • Pembimbing 1: Supriyanto, ST., MT.


    Pembimbing 2: Sunarto, ST., M.Eng. , Editor: Erlin Arvelina

Download...