Path: Top > Skripsi - D4 > 2017 > Jurusan Teknik Sipil > Program Studi Teknik Perawatan & Perbaikan Gedung > 2021
Evaluasi Struktur Atas Gedung Imeri Universitas Indonesia berdasarkan SNI 1726-2019 Dan SNI 2847-2019
Structure Evaluations of The Imeri Tower of The University of Indonesia Are Based on SNI 1726-2019 And SNI 2847-2019
Skripsi, 009 / 2021 / TPPGUndergraduate Theses from JBPTPPOLBAN / 2022-09-23 13:33:36
Oleh : Devid Yusup Dalthon Thoba Biliher - 171144009 & Diana Aristawati - 171144010 (devid.dalthon.tppg17@polban.ac.id)
Dibuat : 2022-09-23, dengan 4 file
Keyword : respon spektra, statik ekivalen, analisis kapasitas struktur
Subjek : response spectra, equivalent static, structural capacity analysis
Perubahan suatu peraturan mengenai syarat bangunan gedung semakin diperbaiki dan disempurnakan. Peraturan yang dikembangkan adalah peraturan ketahanan gempa mengalami perubahan yang sebelumnya SNI 1726-2002 dan sekarang menjadi SNI-1726-2019 dan peraturan persyaratan beton struktural juga mengalami perubahan yang sebelumnya SNI 2847-2002 dan sekarang menjadi SNI 2847-2019. Tujuan penelitian ini adalah melakukan evaluasi kinerja kekuatan struktur dalam menahan beban gempa dengan analisis dinamik respon spektra dan statik ekivalen sesuai dengan persyaratan peraturan SNI-03-1726-2019 dan SNI-2847-2019, dengan menggunakan bantuan software ETABS 2016 dan SpColumn, serta menentukan jenis metode perkuatan elemen struktur yang cocok apabila diperlukan. Dalam proses analisisnya bangunan ini dibagi menjadi tiga bagian terpisah yaitu tower 1, tower 2, dan podium. Sehingga pada ETABS, gaya-gaya dalam pada tower 1 dan tower 2 harus dimasukkan pada titik-titik kolom podium. Pada penelitian ini analisis kapasitas elemen struktur yang dilakukan hanya pada bagian podiumnya saja. Hasil dari analisis didapatkan simpangan antar tingkat pada bangunan tower 1, tower 2, dan podium dominan aman dan pengaruh P-delta untuk seluruh bagian bangunan dapat diabaikan. Bangunan ini hanya memiliki ketidakberaturan torsi, ketidakberaturan akibat pergeseran tegak lurus terhadap bidang, ketidakberaturan non parallel, dan ketidakberaturan akibat diskontinuitas bidang pada elemen vertical pemikul gaya lateral. Lalu, untuk analisis kapasitas balok didapatkan momen lentur, geser, dan torsi yang tidak memenuhi persyaratan pada sebagian besar lantai podium dan untuk analisis kapasitas kolom didapatkan gaya aksial, momen lentur, dan geser yang tidak memenuhi persyaratan pada sebagian besar lantai podium.
Deskripsi Alternatif :Changes to regulations regarding building requirements are increasingly being improved and refined. The regulations developed are the earthquake resistance regulations have changed from SNI 1726-2002 and now to SNI-1726-2019 and the regulations for structural concrete requirements have also changed, which were previously SNI 2847-2002 and now become SNI 2847-2019. The purpose of this study was to evaluate the performance of the strength of the structure in resisting earthquake loads by analyzing the dynamic response spectra and equivalent static by the requirements of the regulations SNI-03-1726-2019 and SNI-2847-2019, using the help of software ETABS 2016 and SpColumn, and determine the type of method of strengthening the structural elements that are suitable if needed. In the analysis process, this building is divided into three parts there are tower 1, tower 2, and the podium. So in ETABS, the internal forces of tower 1 and tower 2 must be entered at the points of the podium column. In this study, the structural element capacity analysis only on the podium. The results of the analysis show that the podium is safe because the deviation between floors and the P-delta for all parts of the building can be ignored. This building only has torsional irregularities, irregularities due to displacement perpendicular to the plane, non-parallel irregularities, and irregularities due to plane discontinuities in vertical elements bearing lateral forces. Then, for the analysis of the beam capacity, bending moments, shears, and torques are not in accordance with the requirements on the entire podium floors and for the analysis of the column capacity, the axial forces, bending moments, and shears are not in accordance with the requirements on the entire podium floors.
Beri Komentar ?#(0) | Bookmark
Properti | Nilai Properti |
---|---|
ID Publisher | JBPTPPOLBAN |
Organisasi | |
Nama Kontak | Erlin Arvelina |
Alamat | Jl. Trsn. Gegerkalong Hilir Ds. Ciwaruga |
Kota | Bandung |
Daerah | Jawa Barat |
Negara | Indonesia |
Telepon | 022 201 3789 ext. 168, 169, 239 |
Fax | 022 201 3889 |
E-mail Administrator | erlin.arvelina@polban.ac.id |
E-mail CKO | erlin.arvelina@polban.ac.id |
Print ...
Kontributor...
- Pembimbing: Dr. Ir. Riawan Gunadi, M.T., Editor: Erlin Arvelina
Download...
File : KELENGKAPAN SKRIPSI - 171144009 & 171144010.pdf
(1537806 bytes)
File : BAB 1 - 171144009 & 171144010.pdf
(806069 bytes)
File : BAB 2 - 171144009 & 171144010.pdf
(1696403 bytes)
File : BAB 5 - 171144009 & 171144010.pdf
(1287502 bytes)