Path: Top > Skripsi - D4 > 2017 > Jurusan Teknik Konversi Energi > Program Studi Teknologi Pembangkit Tenaga Listrik > 2017
Simulasi Kendali Inverter Topologi Neutral Point Clamped Pada Photovoltaic Terkoneksi Jaringan Sebagai Substitusi Suplai Beban Rumah Tangga
Simulation of Photovoltaic Grid Connected Neutral Point Clamped Inverter Control System for Residensial Load Supply Substitute
Tugas Akhir, 005 / 2017 / TPTLUndergraduate Theses from JBPTPPOLBAN / 2018-09-03 15:05:18
Oleh : Dhimas Agiel Dwi Hantoro - 131724005 (dhimas.powerplant.engineering@gmail.com)
Dibuat : 2017-10-27, dengan 4 file
Keyword : Photovoltaic (PV), Grid Connected Inverter, Beban Rumah Tangga, Neutral Point Clamped Multilevel Inverter, Sistem Kendali, Modulation Index Modification
Subjek : Grid Connected Inverter, PV, Residential Load, Neutral Point Clamped Multilevel Inverter, Control System, Modulation Index Modification
PLTS bekerja dengan memanfaatkan irradiance matahari untuk menghasilkan energi listrik. Dengan perubahan kondisi irradiance matahari tiap jamnya suatu sistem kendali dibutuhkan untuk dapat menyesuaikan kebutuhan beban rumah tangga. Pada tugas akhir ini sistem PLTS grid connected dirancang dengan mengunakan inverter topologi Neutral Point Clamped multilevel inverter yang dapat mengubah tegangan rendah dari beberapa sumber DC masukan menjadi tegangan keluaran AC 3 fasa 380 V. Hasil energi listrik AC keluaran dari inverter dengan topologi ini diharuskan untuk mampu mensuplai energi listrik ke beban sehingga pengunaan listrik dari sumber PLN dapat dikurangi. Untuk itu inverter diharapkan dapat mengendalikan naik turun tegangan dengan melakukan Modulation Index Modification agar grid dapat bekerja sebagai suplai energi saat dibutuhkan namun juga dapat menjadi beban pada kondisi PV kelebihan energi agar listrik dapat dijual. Sistem PLTS yang telah dirancang serta beban dan grid dimodelkan pada perangkat lunak MATLAB Simulink, kemudian dilakukan simulasi skenario irradiance matahari dan skenario pembebanan untuk menganalisis pengaruhnya terhadap daya keluaran sistem dan dapat menghasilkan skema kontrol untuk mengatasi masalah tersebut. Kata kunci: Photovoltaic (PV), Grid Connected Inverter, Beban Rumah Tangga, Neutral Point Clamped Multilevel Inverter, Sistem Kendali, Modulation Index Modification.
Deskripsi Alternatif :A Grid Connected Photovoltaic Power Plant System work depending on the sun irradiance to produce electrical energy. With the change of sun irradiance condition each hour a control system is needed to adjust the residential load. In this final project, a grid connected Photovoltaic Power Plant System is design by using a Neutral Point Clamped Multilevel Inverter that is capable of converter a low DC voltage power sources into 380 V 3 phase AC power. The output of this inverter have to be a supplier for residential load so it can subtite the grid form PLN. Therefor this inverter must be control to increase and reduce the output voltage by doing Modulation Index Modification so the grid can work both as supply and load in case ofe overproduce the electrical energy by PV to be sell. . The designed system are modelled in MATLAB Simulink to simulate the irradiance and residential load scenario to analyze its effects on the output power of the system and to create control schemes to overcome te problem. Keywords: Grid Connected Inverter, PV, Residential Load, Neutral Point Clamped Multilevel Inverter, Control System, Modulation Index Modification.
Beri Komentar ?#(0) | Bookmark
Properti | Nilai Properti |
---|---|
ID Publisher | JBPTPPOLBAN |
Organisasi | |
Nama Kontak | Erlin Arvelina |
Alamat | Jl. Trsn. Gegerkalong Hilir Ds. Ciwaruga |
Kota | Bandung |
Daerah | Jawa Barat |
Negara | Indonesia |
Telepon | 022 201 3789 ext. 168, 169, 239 |
Fax | 022 201 3889 |
E-mail Administrator | erlin.arvelina@polban.ac.id |
E-mail CKO | erlin.arvelina@polban.ac.id |
Print ...
Kontributor...
- Pembimbing 1: Dr. Drs. Hartono Budi Santoso, M.T.
Pembimbing 2: Sri Utami, S.ST., M.T., Editor: Erlin Arvelina
Download...
File : KELENGKAPAN TA - 131724005.pdf
(916112 bytes)
File : BAB 1 - 131724005.pdf
(101395 bytes)
File : BAB 2 - 131724005.pdf
(641707 bytes)
File : BAB 5 - 131724005.pdf
(105675 bytes)