Path: Top > Tugas Akhir - D3 > Jurusan Teknik Elektro > Program Studi Teknik Listrik > 2014

Rancang Bangun Modul Praktikum Perhitungan Biaya Energi Listrik Menggunakan kWh Meter Dan kVARh Meter

Design And Build Electrical Energi Cost Calculation Of Laboratory Module With kWh And kVARh

Tugas Akhir, 010 / 2014 / TLI
Undergraduate Theses from JBPTPPOLBAN / 2018-04-17 11:29:38
Oleh : Diana Anggraeni - 111321041 (anggraenidiana92@gmail.com)
Dibuat : 2018-04-17, dengan 4 file

Keyword : Faktor Daya, Pemakaian Energi, Tarif
Subjek : Fower Factor, Energy Consumtion, Cost

Kebutuhan akan energi listrik khususnya industri sudah menjadi hal yang pokok. Setiap pemakaiannya pelanggan dikenakan biaya tertentu tiap bulannya. Hal-hal yang harus diperhatikan dalam biaya energi yaitu pemakaian kWh meter yang terdiri dari WBP (Waktu Beban Puncak) dan LWBP ( Luar Waktu Beban Puncak) serta pemakaian kVARh meter berpengaruh pada beban serta nilai denda yang dikenakan karena memiliki nilai faktor daya kecil atau kurang dari 0,85 (sesuai ketetapan PLN). Maka dari itu pelanggan dikenakan finalty cost (denda) dan batas nilai kVARh meter tidak boleh melebihi 0,62 dari pemakaian total energi (WBP dan LWBP). Untuk mengetahui besarnya energi listrik yang telah digunakan dengan nilai faktor daya yang berbeda-beda serta perhitungan tarif dan denda dengan merubah nilai besarnya beban induktif maka dibuatlah simulator pada proyek akhir ini. Sehingga dapat di hasilkan nilai faktor daya yang berpariatif untuk pengkonversian kedalam tarif dan nilai error yang kecil sesuai yang di harapkan. Kata kunci: Faktor Daya, Pemakaian Energi, Tarif.

Deskripsi Alternatif :

The need for electric energy industry in particular has become a staple. Each customer is charged a certain usage per month. The things that must be considered in the cost of energy consumption kWh meter is composed of PLT (Peak Load Time) and PLOT (Peak Load Out Time) as well as the usage meter kVARh effect on the load and the value of fines imposed for having a small value of power factor or less of 0.85 (corresponding provision PLN). Thus the customer is finalty cost (fines) and boundary value kVARh meter should not exceed 0.62 of the total energy consumption (WBP and LWBP). To determine the amount of electrical energy that has been used with the value of the power factor as well as the different cost and penalty calculations by changing the value of the magnitude of the inductive load simulator then be made at the final project. So that can be produced variant of the force factor for converting into cost and the appropriate small error in the count. Keywords: Fower Factor, Energy Consumtion, Cost.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakErlin Arvelina
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorerlin.arvelina@polban.ac.id
E-mail CKOerlin.arvelina@polban.ac.id

Print ...

Kontributor...

  • Pembimbing 1: Supriyanto, S.T., M.T.

    Pembimbing 2: Drs. Ir. Siswoyo, M.S.I.E., Editor: Erlin Arvelina

Download...