Path: Top > Tugas Akhir - D3 > Jurusan Teknik Elektro > Program Studi Teknik Listrik > 2013
Konservasi Energi Listrik dengan Pemasangan Filter Pasif pada Simulator Rumah Tinggal 900 VA
Electrical Energy Conservation with Setting Passive Filter in Simulation of Living House Energy 900 VA
Tugas Akhir, 037 / 2013 / TLIUndergraduate Theses from JBPTPPOLBAN / 2017-05-12 16:07:24
Oleh : Dian Darmawan - 101321008 (onmydy@yahoo.com)
Dibuat : 2017-05-12, dengan 4 file
Keyword : konservasi energi listrik, harmonisa, filter pasif
Subjek : electrical energy conservation, harmonic, passive filter
Filter pasif merupakan salah satu alat yang dapat digunakan untuk mengatasi atau meminimalisasi arus harmonisa dan untuk memperbaiki faktor daya. Filter pasif terdiri dari komponen pasif seperti induktor dan kapasitor yang dirangkai dengan komponen harmonisa untuk meminimalisasi arus harmonisa. Tujuan tugas akhir ini yaitu mengetahui nilai intensitas konsumsi energi, mengetahui kandungan harmonisa pada beban, dan melakukan pembuatan dan pengujian filter pasif. Dari hasil pengukuran pada beban gabungan kulkas, LHE, jetpump, dan laptop didapatkan arus harmonisa sebesar 64,08% yang melebihi standar IEEE 519-1992 yaitu sebesar 20%. Harmonisa yang dominan muncul adalah harmonisa ke-3. Peredaman harmonisa dilakukan dengan memasang filter pasif (shunt type). Komponen yang dibutuhkan adalah kapasitor 10 μF dan induktor 41,68 mH. Namun filter pasif belum menunjukan hasil yang baik, hasil akhir yaitu sebesar 60,17% dan belum sesuai dengan standar. Kata kunci: konservasi energi listrik, harmonisa, filter pasif.
Deskripsi Alternatif :Passive filter is one of the implement which using to solve and minimize current harmonic and repair the power factor. Passive filter consists of passive component like inductor and capacitor are strung series and component harmonic to minimize the current harmonic. The purpose of this final project is determine value energy consumption intensity, determine the content of harmonic in residential load, and do manufacturing and examination passive filter. The measurements of refrigerator, lamp, jetpump and laptop are available current harmonic as big as 64.08% which exceeds IEEE 519-1992 standard which is 20%. That dominant harmonic appear is third harmonic. Harmonic damping is done by setting passive filter (shunt type). Required component are 10 μF capacitor and 41.68 mH inductor. But this made passive filter not shown good result, the final result is 60.17% and not according to the standard. Keywords: electrical energy conservation, harmonic, passive filter.
Beri Komentar ?#(0) | Bookmark
Properti | Nilai Properti |
---|---|
ID Publisher | JBPTPPOLBAN |
Organisasi | |
Nama Kontak | Erlin Arvelina |
Alamat | Jl. Trsn. Gegerkalong Hilir Ds. Ciwaruga |
Kota | Bandung |
Daerah | Jawa Barat |
Negara | Indonesia |
Telepon | 022 201 3789 ext. 168, 169, 239 |
Fax | 022 201 3889 |
E-mail Administrator | erlin.arvelina@polban.ac.id |
E-mail CKO | erlin.arvelina@polban.ac.id |
Print ...
Kontributor...
- Pembimbing 1: Ir. Heri Budi Utomo
Pembimbing 2: Bambang Priyandono, S.ST., M.Pd., M.T., Editor: Erlin Arvelina
Download...
File : DAFTAR - 101321008.pdf
(531671 bytes)
File : BAB 1 - 101321008.pdf
(250707 bytes)
File : BAB 2 - 101321008.pdf
(1062504 bytes)
File : BAB 5 - 101321008.pdf
(309349 bytes)