RANCANG BANGUN SIMULASI PROTEKSI GANGGUAN TANAH PADA SISTEM DISTRIBUSI MENGGUNAKAN
DESIGN AND BUILD OF PROTECTION SIMULATION GROUND FAULT
Tugas Akhir, 014 / 2012 / TLIUndergraduate Theses from JBPTPPOLBAN / 2015-11-18 09:21:47
Oleh : Dida Nurdiansyah - 091321009
Dibuat : 2013-04-19, dengan 4 file
Keyword : Simulator jaringan distribusi, arus gangguan tanah, Ground Fault Relay (GFR), SEPAM 1000
Subjek : imulator of Distribution network, current of ground fault, Ground Fault Relay (GFR), SEPAM 1000
Sistem proteksi berperan sangat penting untuk menjamin keandalan sistem penyaluran tenaga listrik. Oleh sebab itu perlu diterapkan sistem pengamanan guna mengamankan komponen-komponen baik dari sisi sumber maupun penyulang. Pengamanan yang digunakan untuk mengetahui arus gangguan hubung singkat terutama hubung singkat fasa ke tanah adalah relay gangguan tanah atau Ground Fault Relay (GFR). Dengan mengetahui arus gangguan yang dapat terjadi dan memperhatikan karakteristik serta pola setting peralatan pengaman terpasang, diharapkan dapat diketahui tingkat keandalan penyulang. Untuk itu dibuat simulator proteksi guna mengetahui besar arus hubung singkat fasa ke tanah. Simulasi ini menggunakan relay tipe SEPAM 1000, trafo CT, dan menggunakan MCB 3 fasa sebagai pengaman dengan menggunakan lampu bohlam 100W sebagai beban. Hasil Penelitian ini pada saat pengujian karakteristik dengan mengambil sampel Standard Inverse Time (SIT) didapatkan persen (%) error sebesar 0,01%, dan pada saat pengujian menggunakan simulator jaringan pada sisi sekunder CT tanpa tahanan pentanahan (solid) didapatkan arus hubung singkat 1 fasa ke tanah sebesar 2,44 Ampere, arus hubung singkat 2 fasa ke tanah adalah 3,46 Ampere, dan arus hubung singkat 3 fasa ke tanah adalah 3,75 Ampere. Kata Kunci: Simulator jaringan distribusi, arus gangguan tanah, Ground Fault Relay (GFR), SEPAM 1000
Deskripsi Alternatif :Protection system plays a very important to ensure reliable electrical power supply system. Therefore needs to be applied in order to safeguard the security system components from the source and feeders. Security is used to determine the short circuit fault current is mainly a short-circuit the relay phase to ground disturbance ground or Ground Fault Relay (GFR). By knowing the fault current that can occur and consider the characteristics and patterns of setting safety equipment installed, are expected to know the reliability of the feeders. Simulator for protection was made to determine the phase of the short circuit current to ground. This simulation uses a relay types SEPAM 1000, transformer CT, and using 3-phase MCB as a safety by using a 100W light bulb as a load. The results of this study at the time of testing characteristics by taking samples of Standard Inverse Time (SIT) obtained percent (%) error of 0.01%, and at the time of testing using a network simulator on the secondary side of CT without resistance grounding (solid) obtained a short-circuit current phase to ground of 2.44 Ampere, 2-phase short circuit current to ground is 3.46 amperes, and 3-phase short circuit current to ground is 3.75 Amperes. Keyword: Simulator of Distribution network, current of ground fault, Ground Fault Relay (GFR), SEPAM 1000
Beri Komentar ?#(0) | Bookmark
Properti | Nilai Properti |
---|---|
ID Publisher | JBPTPPOLBAN |
Organisasi | |
Nama Kontak | Erlin Arvelina |
Alamat | Jl. Trsn. Gegerkalong Hilir Ds. Ciwaruga |
Kota | Bandung |
Daerah | Jawa Barat |
Negara | Indonesia |
Telepon | 022 201 3789 ext. 168, 169, 239 |
Fax | 022 201 3889 |
E-mail Administrator | erlin.arvelina@polban.ac.id |
E-mail CKO | erlin.arvelina@polban.ac.id |
Print ...
Kontributor...
- Pembimbing 1: Supriyanto, ST., MT.
Pembimbing 2: Sunarto, ST., M.Eng. , Editor: Erlin Arvelina
Download...
File : DAFTAR - 091321009.pdf
(674001 bytes)
File : BAB 1 - 091321009.pdf
(250561 bytes)
File : BAB 2 - 091321009.pdf
(1389371 bytes)
File : BAB 5 - 091321009.pdf
(242436 bytes)