Path: Top > Tugas Akhir - D3 > 2017 > Jurusan Teknik Mesin > Program Studi Teknik Mesin > 2017
Monitoring Kondisi Turbin Uap Dengan Menggunakan Metode Pengukuran Getaran Di PT Indonesia Power Upjp Kamojang Unit Darajat
Condition Monitoring Of A Steam Turbine Using Vibration Measurement Method At Unit Darajat Of PT Indonesia Power Upjp Kamojang
Tugas Akhir, 035 / 2017 / TMEUndergraduate Theses from JBPTPPOLBAN / 2018-01-12 10:17:19
Oleh : Didi Setiyo Pangestu - 141211040 (setiyo770@gmail.com)
Dibuat : 2018-01-12, dengan 4 file
Keyword : Turbin uap, getaran, amplitudo, time domain, dan frequency domain
Subjek : steam turbine, vibration, amplitude, time domain, and frequency domain
Turbin Uap merupakan salah satu komponen utama yang memiliki peranan penting dalam proses pembangkitan listrik, yaitu sebagai penggerak generator untuk dapat menghasilkan listrik. Karena peranan turbin uap sangat penting dalam sebuah PLTP, maka kondisi turbin uap harus selalu diperhatikan. Salah satu cara untuk mengetahui dan mengontrol kinerja turbin uap maka dilakukan upaya perawatan prediktif dengan cara memonitoring kondisi turbin. Maka dari itu untuk menjaga kinerja turbin perlu adanya sistem perawatan mesin yang optimal, agar kondisi mesin selalu dalam kondisi yang handal dan masa pakai yang termaksimalkan. Agar gejala kerusakan dapat terdeteksi sedini mungkin, perlu dilakukannya monitoring kondisi mesin terutama melalui monitoring getaran mesin, sehingga kerusakan lebih lanjut dan kerugian akibat terhentinya mesin dapat dicegah. Alat ukur yang digunakan dalam pengukuran getaran adalah vibscanner dan vibration accelerometer beserta data akuisisinya. Metode analisis yang digunakan adalah analisis besar amplitudo, comparative dan descriptive. Objek yang diuji adalah turbin uap di PT. Indonesia Power UPJP Kamojang Unit Darajat. Berdasarkan hasil monitoring dan analisis menunjukan bahwa amplitudo pada bearing turbin uap dan generator masih dalam batas standar getaran yang diijinkan oleh ISO 10816-2 level hijau A dengan nilai amplitudo 2.92 mm/s terjadi pada titik TNDEV. Data pengukuran time domain menunjukan impuls-impuls masih dalam keadaan steady (tenang). Frequency domain menunjukan amplitudo tertinggi (0.4495 m/s2) pada titik TDEV dengan frekuensi fundamental turbin sebesar 50 Hz terjadi indikasi gejala kerusakan karena unbalance (frekuensi 50 Hz s/d. 200 Hz) dan kemungkinan kerusakan bearing karena beberapa amplitudo tinggi terjadi pada range frekuensi tinggi (500 Hz s/d. 9000 Hz). Kata Kunci: Turbin uap, getaran, amplitudo, time domain, dan frequency domain.
Deskripsi Alternatif :Steam turbine is one of main component that has important role in electric power generating process, that is as generator drivers for generating electric power. Because the role of steam turbine is very important at PLTP, so the condition of steam turbine should be maintained. One of the method for knowing and controlling the performance of steam turbine is predictive maintenance with monitoring steam turbine condition. To maintain the performance of steam turbine required an optimal machine maintenance system, so condition of the machine always at good performance and maximum lifetime. To detect early sign of damage, it is needed to do monitoring of machine condition specially by monitoring the vibration of machine, so that further damage and lost because of machine stop can be prevented. Measuring tool that used to measure vibration is vibscanner and vibration accelerometer along with its acquisition data. Analysis method that used is analysis of amplitude, comparative and descriptive. Object that tested is steam turbine at PT Indonesia Power UPJP Kamojang Unit Darajat. Based on monitoring and analysis result it show that amplitude of bearings at steam turbine and generator still at standard allowance of vibration that allowed by ISO 10816-2 green level A with amplitude value 2.92 mm/s at TNDEV point. Measuring data of time domain is showing that impulses still at steady condition. Frequency domain show highest amplitude (0.4495 m/s2) at position TDEV with fundamental frequency value of steam at 50 Hz indication of damage because of unbalance occurred (frequency 50 Hz - 200 Hz) and possibility of bearing damage to some high amplitudes occurs in high frequency (500 Hz-9000 Hz). Keywords: steam turbine, vibration, amplitude, time domain, and frequency domain.
Beri Komentar ?#(0) | Bookmark
Properti | Nilai Properti |
---|---|
ID Publisher | JBPTPPOLBAN |
Organisasi | |
Nama Kontak | Erlin Arvelina |
Alamat | Jl. Trsn. Gegerkalong Hilir Ds. Ciwaruga |
Kota | Bandung |
Daerah | Jawa Barat |
Negara | Indonesia |
Telepon | 022 201 3789 ext. 168, 169, 239 |
Fax | 022 201 3889 |
E-mail Administrator | erlin.arvelina@polban.ac.id |
E-mail CKO | erlin.arvelina@polban.ac.id |
Print ...
Kontributor...
- Pembimbing 1: Ir. Ating Sudradjat, M.Sc.
Pembimbing 2: Drs. Parno Raharjo, M.Pd., M.Sc., Ph.D., Editor: Erlin Arvelina
Download...
File : KELENGKAPAN TA - 141211040.pdf
(1002495 bytes)
File : BAB 1 - 141211040.pdf
(136693 bytes)
File : BAB 2 - 141211040.pdf
(1131219 bytes)
File : BAB 5 - 141211040.pdf
(102913 bytes)