Analisis Potensi Kerusakan pada Secondary Pump A di PT. Indonesia Power UPJP Kamojang Unit Darajat

Potential Analysis Damage On Secondary Pump A in PT. Indonesia Power UPJP Kamojang Unit Darajat

Tugas Akhir, 006 / 2018 / TME
Undergraduate Theses from JBPTPPOLBAN / 2019-01-22 09:38:14
Oleh : Dimas Maulana Putra Rahmanato - 151211005 (mprdimasmbe@gmail.com)
Dibuat : 2019-01-22, dengan 4 file

Keyword : vibrasi, analisis kerusakan, amplitudo
Subjek : Vibration, Analysis of failure, amplitude

Pompa sentrifugal adalah alat yang dapat mengalirkan air untuk pendinginan terhadap oli, sama halnya di PT. Indonesia Power UPJP Kamojang Unit Darajat. Secondary pump termasuk pompa sentrifugal yang digunakan sebagai mesin bantu produksi. Mesin ini perluydilakukan inspeksi getaran (vibration), agar jika terjadi kerusakan dapata dideteksi sedini mungkin, sehingga kerusakan lebih lanjut dan kerugian akibat berhentinya mesin dapatydicegah. Getaran dapat digunakan untuk mendeteksi kerusakan atau gangguan pada mesin yang berputar termasuk pompa sentrifugal. Kurangnya informasi mengenai karakteristik getaran pada pompa ini yang menyebabkan diperlukannya pengujian untuk mengetahui karakteristik getaran pada pompa sentrifugal. Alat yang digunakan adalah vibscanner. Dengan parameter pengujiannya analisis getaran terhadap amplitude, time domain dan frequency. Analisis getaran dilakukan pada pompa sentrifugal untuk pengambilan data, dengan metode analisis yang digunakan adalah amplitude comparative dan descriptive. Hasil yang didapat dengan metode analisis trending dan komparatif adalah besar kenaikan amplitudo kecepatan yang terjadi pada pengukuran masih dalam toleransi mengacu kepada standar ISO 108163-3 dan jika menggunakan metode deskriptif didapat hasil spektrum getaran untuk 1 x ff, 2 x ff, 3 x ff, 4 x ff, 5 x ff dan bahkan sampai 6 x ff, yang mana itu merupakan potensi gangguan secondary pumpA disebabkan oleh misalignment dan kerusakan bearing. Kata kunci: vibrasi, analisis kerusakan, amplitudo.

Deskripsi Alternatif :

Centrifugal pump is an equipment that able to flow the water for cooling an oil, in similar way in PT. Indonesia Power UPJP Kamojang Unit Darajat. The secondary pump is a centrifugal pump which helpful for production activity. This machine required vibrations inspection to detect some failure as soon as possible, also prevent failure in the future and losses as an effect from trip machine. Vibration inspection can be used for detecting failures on rotating equipment like centrifugal pump. Lack of information about vibrations characteristic on centrifugal pump is a reason why this centrifugal pump needs to inspect. Equipment that is used in this inspection is vibscanner. Parameter used for the inspection are amplitude, time domain, and frequency. The methode of analysis are analysis number of amplitude, comparative, and descriptive. The result from analysis of trending and comparative are the increase of velocity amplitude still maintain inside the tolerance based on ISO 108163-3 standard. Also, the result from descriptive analysis are getting vibrations spectrum for 1 x ff, 2 x ff, 3 x ff, 4 x ff, 5 x ff, even for 6 x ff that can be inferred as failure potency from misalignment and bearing failure for secondary pump A. Keywords: Vibration, Analysis of failure, amplitude.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakErlin Arvelina
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorerlin.arvelina@polban.ac.id
E-mail CKOerlin.arvelina@polban.ac.id

Print ...

Kontributor...

  • Pembimbing 1: Ir. Mokhamad Munir Fahmi, M.T.

    Pembimbing 2: Ir. Ating Sudradjat, M.Sc., Editor: Erlin Arvelina

Download...