Rancang Bangun Simulator Tap Changer Transformator Sebagai Pengaturan Tegangan Sistem Distribusi Tenaga Listrik Dengan Panjang Penyulang 30 Km

Design And Build Transformer Tap Changer As Voltage Regulation Of Power Distribution Systems Simulator With Long Feeders 30 Km

Tugas Akhir, 033 / 2014 / TLI
Undergraduate Theses from JBPTPPOLBAN / 2018-04-26 08:57:05
Oleh : Dwiki Setiabudi - 1111321043 (dwiki.setiabudi@yahoo.com)
Dibuat : 2018-04-26, dengan 4 file

Keyword : Tap Changer, Ratio Transformator, Sadapan
Subjek : Tap Changer, Ratio Transformer, Lead

Pusat-pusat pembangkit tenaga listrik biasanya berada jauh dari pusat beban, hal ini mengakibatkan kerugian yang cukup besar dalam penyaluran daya listrik. Kerugian tersebut disebabkan oleh jarak pada saluran yang cukup panjang. Sehingga, dalam penyaluran daya listrik melalui transmisi maupun distribusi, akan mengalami drop voltage atau jatuh tegangan sepanjang saluran yang dilalui. Ada beberapa cara untuk memperbaiki jatuh tegangan dan salah satunya adalah menggunakan metode tap changer yang terdapat pada transformator daya. Kenaikan dan penurunan tegangan di jaringan distribusi tegangan menengah (JTM) dapat dilakukan dengan menambah atau mengurangi jumlah tap yang terdapat pada transformator daya. Dengan menaikkan tegangan pada gardu induk melalui tap changer pada transformator daya dapat meningkatkan tegangan di ujung saluran sehingga pelayanan dapat mencapai sampai batas-batas toleransi. Melihat pengaruh naik turunnya tegangan pada konsumen, maka tujuan proyek akhir ini adalah membuat simulator tap changer transformator sebagai pengaturan tegangan sistem distribusi tenaga listrik. Transformator yang memiliki 6 tap pada sisi primer dan 2 tap pada sisi sekunder mensimulasikan pengaturan tegangan dengan merubah posisi tap pada sisi primer. Analisis yang akan dilakukan adalah mengenai ratio transformator dan sadapan dari tegangan nominal. Metodologi yang dilakukan adalah identifikasi masalah, perancangan dan pembuatan simulator, menguji dan menganalisa hasil pengujian. Simulator yang telah dibuat mempunyai ratio antara tap primer 420V, 400V, 380V, 360V dan 340V dengan tap sekunder 220V berturut-turut adalah 1.83, 1.75, 1.66, 1.58, dan 1,49. Sedangkan ratio dengan tap 127V adalah 3.16, 3.02, 2.88, 2.72 dan 2.57. Sadapan pada tap 380 merupakan tegangan nominal yang diasumsikan 100%, tap 400 mempunyai tegangan 94.19% dari tegangan nominalnya, begitu juga dengan tap 420 yang memiliki tegangan 89.41% dari tegangan nominal. Kata kunci: Tap Changer, Ratio Transformator, Sadapan.

Deskripsi Alternatif :

The centers of power plants usually located far from load centers, this has resulted in a substantial loss in the distribution of electrical power. The losses caused by the distance at which the channel is long enough. Thus, the distribution of electric power through transmission and distribution, will experience a voltage drop or voltage drop along the line traversed. There are several ways to fix the voltage drop and one of them is using the tap changer found in power transformers. The increase and decrease voltage in medium voltage distribution network (JTM) can be done by adding or reducing the number of taps which are in power transformers. By raising the voltage at the substation through the tap changer power transformer can increase the voltage at the end of the channel so that the service can reach up to the limits of tolerance. Seeing the effect of voltage fluctuation on the consumer, the final goal of this project is to create a simulator tap changer transformer as voltage regulation of power distribution systems. The transformer has a 6 tap on the primary side and secondary side 2 simulates tapping on the voltage settings by changing the position of the tap on the primary side. The analysis will be done is the transformer ratio and intercepts of the nominal voltage. The methodology does is identify the problem, designing and manufacturing simulators, test and analyze the test results. Simulators have been made to have the ratio between primary tap 420V, 400V, 380V, 360V and 340V to 220V secondary tap row is 1.83, 1.75, 1.66, 1.58, and 1,49. While the ratio 127V tap is 3.16, 3.02, 2.88, 2.72 and 2.57. Lead in tap nominal voltage 380 is assumed to be 100%, 400 has a voltage tap 94.19% of the nominal voltage, as well as a voltage tap 420 which has 89.41% of the nominal voltage. Keywords: Tap Changer, Ratio Transformer, Lead.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakErlin Arvelina
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorerlin.arvelina@polban.ac.id
E-mail CKOerlin.arvelina@polban.ac.id

Print ...

Kontributor...

  • Pembimbing 1: Asikin S. Y., S.T.

    Pembimbing 1: Ir. Heri Budi Utomo, Editor: Erlin Arvelina

Download...