Perancangan Circulating Water Pump Tipe Vertical Dry Pit Untuk Sistem Pendingin Tipe Terbuka di PLTU Cirebon

The Design of Circulating Water Pump Vertical Dry Pit Type for The Cooling System at PLTU Cirebon

Skripsi, 012 / 2021 / TPTL
Undergraduate Theses from JBPTPPOLBAN / 2022-11-29 10:55:35
Oleh : Efraim Purba - 171724010 (Efraim.purba.tptl17@polban.ac.id)
Dibuat : 2022-11-29, dengan 4 file

Keyword : Sistem pendingin tipe terbuka, CWP, Kondensor
Subjek : Open cycle type cooling system, CWP, Condensor

Sistem pendingin pada pembangkit pada umumnya memiliki dua tipe, yaitu sistem pendingin tipe tertutup, dan sistem pendingin tipe terbuka. Sistem pendingin tipe terbuka akan mengalirkan air pendingin yang berasal dari laut menuju kondensor dengan menggunakan circulating water pump untuk mengkondensasi uap. PLTU Cirebon terletak di pesisir laut Jawa dengan sistem pendingin tipe tertutup. Air laut tersebut dapat dimanfaatkan untuk menjadi sumber air pendingin pada kondensor di PLTU Cirebon. Pompa yang digunakan harus mampu menyuplai air pendingin sebesar 78.70 m3/h dengan head sebesar 44,61 meter untuk mengatasi beban panas (duty) sebesar 3,28E+9 kJ/h pada kondensor. Pompa yang akan dirancang pada sistem ini merupakan pompa submersible dengan tipe vertical dry pit dengan tekanan kerja 3 bar pada sisi discharge, jumlah sudu sebanyak 11 buah dan putaran pompa sebesar 315 rpm dengan daya hidrolik sebesar 2628 kW. Analisa yang dilakukan adalah nilai tertinggi debit air pendingin yang dibutuhkan terdapat pada bulan Juni sebesar 21.995 m3/s dan nilai terendahnya terdapat pada bulan Desember sebesar 16.414 m3/s. Selain dari pada itu, perubahan ketinggian permukaan air laut tidak akan membuat pompa dalam keadaan kavitasi karena nilai NPSHav selalu lebih besar dari nilai NPSHreq. Selanjutnya, jarak antara pintu sisi masuk dan sisi buangan air pendingin berjarak 158 meter agar tidak terjadinya sirkulasi air pendingin. Kata kunci: Sistem pendingin tipe terbuka, CWP, Kondensor.

Deskripsi Alternatif :

The cooling system in power plants generally has two types, namely the closed type cooling system and the open type cooling system. The open-type cooling system will flow cooling water from the sea to the condenser by using a circulating water pump to condense the steam. PLTU Cirebon is located on the coast of the Java Sea with a closed type cooling system. The sea water can be used as a source of cooling water in the condenser at the Cirebon PLTU. The pump used must be able to supply cooling water of 78,707 m3/h with a head of 44.61 meters to overcome the heat load (duty) of 3.287E+9 kJ/h on the condenser. The pump that will be designed in this system is a submersible pump with a vertical dry pit type with a working pressure of 3 bar on the discharge side, a total of 11 blades and a pump rotation of 315 rpm with a hydraulic power of 2628 kW. The analysis carried out is that the highest value of cooling water discharge required is in June of 21,995 m3/s and the lowest value is in December of 16,414 m3/s. Apart from that, changes in sea level will not cause the pump to cavitate because the NPSHav value is always greater than the NPSHreq value. Furthermore, the distance between the entrance and the exhaust side of the cooling water is 158 meters so that there is no circulation of cooling water. Keyword: Open cycle type cooling system, CWP, Condensor.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakErlin Arvelina
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorerlin.arvelina@polban.ac.id
E-mail CKOerlin.arvelina@polban.ac.id

Print ...

Kontributor...

  • Pembimbing 1: Aceng Daud, S.T., M.Eng.

    Pembimbing 2: Budi Suharto, S.T., M.Eng., Editor: Erlin Arvelina

Download...