Path: Top > Tugas Akhir - D3 > Jurusan Teknik Refrigerasi dan Tata Udara > Program Studi Teknik Refrigerasi dan Tata Udara > 2012
Rancang Bangun Sistem Refrigerasi Kompresi Uap Untuk Prototype AHU (Air Handling Unit)
Design Of Refrigeration System Vapour Compression For Prototype AHU (Air Handling Unit)
Tugas Akhir, 035 / 2012 / RTUUndergraduate Theses from JBPTPPOLBAN / 2014-07-04 10:26:49
Oleh : Ega Febrian - 091611034 (febrianegga@yahoo.com)
Dibuat : 2014-07-04, dengan 4 file
Keyword : air conditioning, direct expansion, all air system, air handling unit, temperatur
Subjek : Refrigeration, direct expansion, multizone, air conditioning, COP (coefficient of performance)
Pengkondisian Udara pada umumnya mempunyai suhu kenyamanan pada temperatur 20°C-25°C. Untuk mendapatkan suatu temperatur kenyamanan dalam bekerja atau beraktifitas maka dibutuhkan suatu sistem atau alat pengkondisian udara atau yang sudah sering di dengar dengan AC (air conditioning). Tujuan dalam perancangan ini adalah membuat sebuah sistem refrigerasi untuk pengkondisian udara pada temperatur kenyamanan bekerja atau beraktifitas dengan sistem all air system. Perancangan dilakukan pada sistem refrigerasi kompresi uap pada ruangan atau kabin berukuran 40x40x40(cm) dengan beban pada ruangan lampu 25watt, yang dilengkapi dengan condensing unit dengan kapasitas 1/5 HP dan ducting sebagai pengkondisian udara secara all air system pada AHU (air handling unit). Selain itu sistem menggunakan direct expansion dan sistem pemilihan pada komponen sendiri menggunakan software pada dancap (danfos capilar) khususnya pada pemilihan pipa kapiler sebagai hasilnya agar pendinginan yang diinginkan pada sistem terproses secara baik. Pembuatan mesin ini terbagi dengan beberapa proses lainnya yaitu pemilihan komponen, penginstalasian, dan pengujian. Pemilihan komponen dilakukan setelah melakukan perhitungan beban pendinginan. Panjang evaporator berdasarkan dari hasil perhitungan. Pemilihan kondensing unit dipilih sesuai dengan beban pendinginan dan dikonversikan ke dalam tabel pemilihan kondensing unit bermerk "KULTHRON". Dari hasil perhitungan beban didapat bahwa dengan kapasitas condensing unit 150,051 watt, mesin dapat mendinginkan Temperatur kabin 20°C dengan temperatur evaporasi -4°C dan temperatur kondensasi 43°C. Performansi sistem refrigerasi hasil pengukuran adalah 4,13 untuk COPaktual dan 5,94 untuk COPcarnot, effisiensi sebesaar 0,69. Hasil kajian dari perancangan ini menunjukan bahwa hasil rancangan lebih tinggi dari pada hasil pengukuran dikarenakan banyak faktor yang mempengaruhi pada saat pengukuran seperti titik pengukuran, alat ukur yang digunakan, cuaca pada saat pengukuran, insulasi pada pemipaan dan kabin, dll. Kata kunci: air conditioning, direct expansion, all air system, air handling unit, temperatur.
Deskripsi Alternatif :The air conditioning generally have the comfort temperature at 20°C-25°C. To get a comfortable temperature in the work or activity is required of a system or appliance or air conditioning that is often heard with AC (air conditioning). The purpose in this design is to make a refrigeration system for air conditioning in temperatures convenience to work or activities with a system of all water system. Design carried out in vapor compression refrigeration system in a room or cabin measuring 40x40x40(cm) with a 25watt light load on the room, which is equipped with a condensing unit with a capacity of 1/5 HP and ducting for air conditioning in all water systems in the AHU ( water handling unit). Besides using the direct expansion system and the electoral system on its own components using the software on dancap (danfos capilar) especially in the election as a result of the capillary tube so that the desired cooling systems are properly processed. Similarly, the manufacture of this machine are divided by some other process is the selection of components, installation, and testing. After calculating the cooling load, then made the selection of components. Evaporator length obtained from the calculation, and the selection unit condensing selected according to the cooling load and converted into a table selection unit condensing branded "KULTHRON". From the calculation results obtained that the burden of condensing unit with a capacity of 150.051 watts, the machine can cool the cabin temperature of 20°C to -4°C evaporating temperature and condensing temperature of 43°C. So that the refrigeration system performance measurement results was 4.13 to 5.94 for COPcarnot COPaktual and resulting efficiency sebesaar 0.69. The results of the design of this study indicate that the design is higher than the measurement results due to many factors that affect such measurements at the point of measurement, measuring instruments are used, the weather at the time of measurement, piping and insulation in the cabin, etc. Key words : Refrigeration, direct expansion, multizone, air conditioning, COP (coefficient of performance).
Beri Komentar ?#(0) | Bookmark
Properti | Nilai Properti |
---|---|
ID Publisher | JBPTPPOLBAN |
Organisasi | |
Nama Kontak | Erlin Arvelina |
Alamat | Jl. Trsn. Gegerkalong Hilir Ds. Ciwaruga |
Kota | Bandung |
Daerah | Jawa Barat |
Negara | Indonesia |
Telepon | 022 201 3789 ext. 168, 169, 239 |
Fax | 022 201 3889 |
E-mail Administrator | erlin.arvelina@polban.ac.id |
E-mail CKO | erlin.arvelina@polban.ac.id |
Print ...
Kontributor...
- Pembimbing 1: Drs. Ismail Wellid, MT.
Pembimbing 2: A. P. Edi Sukamto, ST., MT.
, Editor: Erlin Arvelina
Download...
File : DAFTAR - 091611034.pdf
(600270 bytes)
File : BAB 1 - 091611034.pdf
(332424 bytes)
File : BAB 2 - 091611034.pdf
(854487 bytes)
File : BAB 6 - 091611034.pdf
(838467 bytes)