Path: Top > Tugas Akhir - D3 > Jurusan Teknik Refrigerasi dan Tata Udara > Program Studi Teknik Refrigerasi dan Tata Udara > 2012
Pengaruh Diameter Orifice Terhadap Kapasitas Pendinginan Tabung Vortex
Influence Diametre Orifice to Cooling Capacity Vortex Tube
Tugas Akhir, 016 / 2012 / RTUUndergraduate Theses from JBPTPPOLBAN / 2014-07-04 08:42:16
Oleh : Esa Finisari - 091611013 (sha_esa@yahoo.co.id)
Dibuat : 2014-07-04, dengan 4 file
Keyword : Tabung Vortex, Diameter Orifice, Kapasitas Pendinginan
Subjek : Vortex Tubes, Orifice Diametre, Cooling Capacity
Tabung Vortex adalah suatu sistem refrigerasi yang menghasilkan udara panas dan dingin dari udara bertekanan. Tabung vortex dapat berfungsi sebagai pendingin dengan udara sebagai refrigerant tanpa menggunakan refrigerant konvensional. Pada sistem refrigerasi tabung vortex, nilai kapasitas pendinginan bergantung pada banyak faktor diantaranya tekanan udara masukan, debit udara dingin keluaran, geometri komponen tabung vortex dan variabel lainnya. Kapasitas pendinginan tabung vortex merupakan fungsi penurunan temperatur dan laju aliran massa udara dingin keluaran. Analisis tugas akhir ini bertujuan untuk mengetahui pengaruh diameter orifice terhadap kapasitas pendinginan tabung vortex dan temperatur udara dingin keluaran yang di hasilkan tabung vortex. Tabung vortex yang digunakan memiliki konstruksi sebagai berikut : panjang tabung 225 mm, diameter tabung 12 mm, Diameter orifice 5 mm dan 6 mm, Chamber berdiameter 24 mm, Nosel alur 2 dan sudut katup 40⁰. Pada tugas akhir ini diperoleh kapasitas pendinginan tertinggi yaitu tabung vortex dengan diameter orifice 5 mm dengan Qd sebesar 0.075 kW pada tekanan 5 bar sedangkan tabung vortex dengan diameter orifice 6 mm dengan Qd sebesar 0.040 kW pada tekanan 5 bar. Temperatur udara dingin terendah keluaran tabung vortex menggunakan diameter orifice nosel 5mm mencapai -5.6⁰C pada tekanan 5 bar sedangkan menggunakan diameter orifice 6mm temperatur udara dinginnya mencapai -2⁰C. Kata Kunci: Tabung Vortex, Diameter Orifice, Kapasitas Pendinginan
Deskripsi Alternatif :Vortex tube is a refrigeration system that produces hot and cold air from compressed air. Vortex tube can be used as a cooling without the use of refrigerant. The cooling capacity of vortex tube refrigeration system depends on many factors including air pressure input, the output flow of cold air, the geometry of the vortex tube components and other variables. Vortex tube cooling capacity is a function of the temperature and the cold air mass flow rate output. Analysis of final project to investigate the effect of orifice diametre to the vortex tube cooling capacity and temperature of the cold air output generated by vortex tube.Vortex tube which are used in this project have the following construction : 225 mm tube length, tube diametre 12 mm, 5 mm and 6 mm orifice diametre, 24 mm in diametre chamber, nozzle flow valve and with an angle of 40⁰. At this final project the highest cooling capacity of vortex tube with an orifice diametre of 5 mm with Qd of 0.075 kW at a pressure of 5 bar while the vortex tube with 6 mm diametre orifice with a Qd of 0.040 kW at a pressure of 5 bar. The lowest temperature of the cold air vortex tube output using a 5 mm diametre orifice is -5.6ºC at a pressure of 5 bar while using 6mm orifice diametre cold air temperatures is -2ºC. Keywords: Vortex Tubes, Orifice Diametre, Cooling Capacity
Beri Komentar ?#(0) | Bookmark
Properti | Nilai Properti |
---|---|
ID Publisher | JBPTPPOLBAN |
Organisasi | |
Nama Kontak | Erlin Arvelina |
Alamat | Jl. Trsn. Gegerkalong Hilir Ds. Ciwaruga |
Kota | Bandung |
Daerah | Jawa Barat |
Negara | Indonesia |
Telepon | 022 201 3789 ext. 168, 169, 239 |
Fax | 022 201 3889 |
E-mail Administrator | erlin.arvelina@polban.ac.id |
E-mail CKO | erlin.arvelina@polban.ac.id |
Print ...
Kontributor...
- Pembimbing 1: Drs. Faldian
Pembimbing 2: Ir. Arda Rahardja Lukitobudi, M.Eng.
, Editor: Erlin Arvelina
Download...
File : DAFTAR - 091611013.pdf
(352944 bytes)
File : BAB 1 - 091611013.pdf
(176248 bytes)
File : BAB 2 - 091611013.pdf
(339743 bytes)
File : BAB 5 - 091611013.pdf
(222760 bytes)