Path: Top > Skripsi - D4 > 2017 > Jurusan Teknik Konversi Energi > Program Studi Teknologi Pembangkit Tenaga Listrik > 2021

Perancangan Pompa pada Siklus Rankine Organik Menggunakan Fluida Kerja R-600 dengan Memanfaatkan Brine di PLTP Ulubelu

Design of Pump in Organic Rankine Cycle Using Works Fluid R-600 by Utilizing Brine PLTP Ulubelu

Skripsi, 014 / 2021 / TPTL
Undergraduate Theses from JBPTPPOLBAN / 2022-11-29 11:01:22
Oleh : Felyan Yunia Restika - 171724012 (felyan.yunia.tptl17@polban.ac.id)
Dibuat : 2022-11-29, dengan 4 file

Keyword : Siklus Rankine Organik, Pompa, R-600, Aspen Hsys
Subjek : Organic Rankine Cycle, Pump, R-600, Aspen HYSYS

Pembangkit Listrik Tenaga Panas Bumi Ulubelu memiliki sumber air panas brine dengan temperatur berkisar antara 169-170 °C dan tekanan 5-8 bar yang langsung diinjeksikan ke sumur injeksi. Sumber air panas brine tersebut dapat dimanfaatkan sebagai pemanas untuk siklus rankine organik berkapasitas 404,9 kW dengan menggunakan fluida R-600. Siklus ini terdiri dari empat komponen yaitu evaporator, turbin, kondensor dan pompa yang disimulasikan menggunakan perangkat lunak Aspen Hysys. Perpindahan panas antara fluida R-600 dengan sumber air panas brine terjadi di dalam evaporator. Untuk dapat mensirkulasikan fluida R-600 menuju evaporator perlu dirancang sebuah komponen berupa pompa. Perancangan komponen utama pompa menggunakan data yang didapatkan dari hasil simulasi siklus rankine organik. Berdasarkan data tersebut, diperoleh rancangan pompa yang dapat beroperasi pada tekanan 7,436 bar di sisi discharge dan 5 bar di sisi suction dengan laju alir volume sebesar 0,0482 m3/s, head total pompa 47,30 m dan jumlah sudu sebanyak 6 buah. Pompa yang dirancang bekerja pada putaran 1500 rpm dengan daya hidrolisis sebesar 12,641 kW dan efisiensi sebesar 83%. Kata Kunci: Siklus Rankine Organik, Pompa, R-600, Aspen Hsys.

Deskripsi Alternatif :

The Ulubelu Geothermal Power Plant has brine springs with temperatures ranging from 169 to 170°C and 5-8 bar pressures which are directly injected into injection wells. The brine springs can be used as a heater for the organic Rankine cycle with a capacity of 404,9 kW using R-600 fluid. This cycle consists of four components: the evaporator, turbine, condenser and pump which are simulated using Aspen HYSYS software. The heat transfer between the R-600 fluid and the brine springs happens in the evaporator. To be able to circulate the R-600 fluid to the evaporator, it is necessary to design a pump. The design of the main components of the pump uses the data obtained from the simulation results of the organic Rankine cycle. Based on these data, the pump design can operate at a 7,436 bar pressure on the discharge side and 5 bar on the suction side with a 0,0482 m3/s volume flow rate, 47,30 m a total pump head and 6 blades. The designed pump works at 1500 rpm rotation with a 12,641 kW hydrolysis power and 83% efficiency. Keywords: Organic Rankine Cycle, Pump, R-600, Aspen HYSYS.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakErlin Arvelina
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorerlin.arvelina@polban.ac.id
E-mail CKOerlin.arvelina@polban.ac.id

Print ...

Kontributor...

  • Pembimbing 1: Drs. Maridjo, M.T.

    Pembimbing 2: Ika Yuliyani, S.T., M.T., Editor: Erlin Arvelina

Download...