Pengaruh Burden CT Terhadap Ketelitian Pengukuran Energi Listrik Pada Pengukuran Tidak Langsung
CT Burden Effect On Accuracy Electrical Energy Measurement At Indirect Measurements
Tugas Akhir, 025 / 2014 / TLIUndergraduate Theses from JBPTPPOLBAN / 2018-04-16 16:26:20
Oleh : Ferianty Supriyanto - 111321049 (feriantyeri@gmail.com)
Dibuat : 2018-04-16, dengan 4 file
Keyword : trafo arus, pengujian, burden, ketelitian, error rasio
Subjek : current transformer, testing, burden, accuracy, error
Pada pengukuran energi listrik tidak langsung, memerlukan trafo arus untuk menurunkan arus dari arus tinggi menjadi arus rendah sesuai kapasitas alat ukur yang akan digunakan. Trafo arus dalam melayani peralatan alat ukur harus memenuhi kapasitas beban / burdennya, yaitu beban fix seperti alat ukur dan beban variabel yaitu kabel penghubungnya. Selama beban tersebut memenuhi syarat dengan tidak melebihi kapasitas burdennya, maka sensitivitas atau ketelitian alat ukur dapat di penuhi. Oleh karena itu perhitungan beban variabel dan beban fix haruslah diperhatikan. Tujuan proyek akhir ini adalah mengetahui karakteristik trafo arus dan pengaruh burden trafo arus terhadap ketelitian pengukuran energi listrik. Metode yang digunakan adalah dengan membuat perancangan, perbaikan alat yang telah ada dan pengujian secara langsung. Data-data yang diperlukan diperoleh dari hasil pengujian. Setelah data yang diperoleh sudah cukup, data tersebut diolah untuk mendapatkan kurva karakteristik trafo arus yang diuji. Hasil dari pengujian tersebut, terjadi peningkatan error rasio yang signifikan jika beban sekunder melebihi burden trafo arus yaitu sebesar ± 60%. Hasil dari proyek akhir ini diharapkan kita dapat lebih mengenal karakteristik dari trafo arus dan membuktikan teori bahwa pembebanan sekunder berlebihan berpengaruh terhadap error rasio trafo arus. Kata Kunci: trafo arus, pengujian, burden, ketelitian, error rasio.
Deskripsi Alternatif :In the indirect measurement of electrical energy, require current transformer to reduce the flow of high current into a low current capacity measurement tool suitable to be used. Current transformer measuring instrument in the service of the equipment must meet the load capacity / burden, the burden of such fixed and variable load measuring devices, namely the connecting cable. As long as the load does not exceed qualified with its burden, then the sensitivity or precision measuring instrument can be fulfilled. Therefore, the calculation of the variable load and fixed load should be considered. The purpose of this final project was to determine the characteristics of the current transformer and burden current transformer influence on accuray electrical energy measurement. The method used is to make the planning, improvement of existing tools and testing directly. Necessary data obtained from the test results. Once enough data has been obtained, the data is processed to obtain the characteristic curve of current transformer under test. The results of these tests, there was a significant increase in the error rate when the load exceeds the burden of the current transformer secondary is equal to ± 60%. The results of this final project is expected we can get to know the characteristics of the current transformer and prove the theory that excessive secondary loading effect on the error ratio of the current transformer. Keywords: current transformer, testing, burden, accuracy, error. ratio.
Beri Komentar ?#(0) | Bookmark
Properti | Nilai Properti |
---|---|
ID Publisher | JBPTPPOLBAN |
Organisasi | |
Nama Kontak | Erlin Arvelina |
Alamat | Jl. Trsn. Gegerkalong Hilir Ds. Ciwaruga |
Kota | Bandung |
Daerah | Jawa Barat |
Negara | Indonesia |
Telepon | 022 201 3789 ext. 168, 169, 239 |
Fax | 022 201 3889 |
E-mail Administrator | erlin.arvelina@polban.ac.id |
E-mail CKO | erlin.arvelina@polban.ac.id |
Print ...
Kontributor...
- Pembimbing 1: Drs. Dwi Asmono, M.Pd.
Pembimbing 2: Ir. Hari Purnama, M.Eng., Editor: Erlin Arvelina
Download...
File : DAFTAR - 111321049.pdf
(668346 bytes)
File : BAB 1 - 111321049.pdf
(245755 bytes)
File : BAB 2 - 111321049.pdf
(629477 bytes)
File : BAB 5 - 111321049.pdf
(242731 bytes)