Path: Top > Skripsi - D4 > 2017 > Jurusan Teknik Konversi Energi > Program Studi Teknologi Pembangkit Tenaga Listrik > 2017

Rancangan Circulating Fluidized Bed Incinerator Pada Pembangkit Listrik Tenaga Sampah Kapasitas 10 MW Di Kota Bandung

The Design of Circulating Fluidized Bed Incinerator for 10 MW Municipal Solid Waste Power Plant in Bandung City

Tugas Akhir, 007 / 2017 / TPTL
Undergraduate Theses from JBPTPPOLBAN / 2018-09-03 15:05:20
Oleh : Fikri Chaekal - 131724008 (fikrichaekal@gmail.com)
Dibuat : 2017-12-07, dengan 4 file

Keyword : Incinerator, fluidized, CFB, ruang bakar
Subjek : Incinerator, fluidized, CFB, combustion chamber, furnace

Incinerator merupakan alat pembakar sampah yang umumnya dapat digunakan sebagai alat pemanas air pada pembangkit listrik tenaga sampah. Dalam tugas akhir ini dilakukan perancangan incinerator dengan jenis fluidized bed combustion pada pembangkit listrik tenaga sampah kapasitas 10 MW. Perancangan ruang bakar ini meliputi perhitungan laju panas pada uap, kesetimbangan energi pembakaran, kesetimbangan massa, penampang melintang ruang bakar untuk memanaskan air menjadi uap dengan total panas sebesar 31,629 MWt. Sehingga diperlukan incinerator dengan panas input sebesar 43,814 MW dengan bahan bakar sampah dengan nilai kalor sebesar 14.932,12 kJ/kg serta dimensi penampang melintang sebesar 13,772 m2, panjang 5,249 m, lebar 2,624 m, tinggi 23,73 m, luas udara primer sebesar 8,84 m2 serta kecepatan fluidasi sebesar 4,52 m/s. Kata kunci: Incinerator, fluidized, CFB, ruang bakar.

Deskripsi Alternatif :

Incinerator is a waste burner tool that can generally be used as a water heater in a waste power plant. in this final project is to design an incinerator with the type of fluidized bed combustion in waste power plant capacity of 10 MW. The design of this furnace includes calculation of steam heat rate, combustion energy equilibrium, mass equilibrium, cross section of furnace to warm water into vapor with total heat of 31.629 MWt. Hence, an incinerator with a heat input of 43.814 MW with waste fuel with a calorific value of 14,932.12 kJ / kg and cross-sectional dimension 13.772 m2, length 5.249 m, width 2.624 m, height 23.73 m, primary airspace of 8.84 m2 and fluidation speed of 4.52 m / s. Keywords: Incinerator, fluidized, CFB, combustion chamber, furnace.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakErlin Arvelina
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorerlin.arvelina@polban.ac.id
E-mail CKOerlin.arvelina@polban.ac.id

Print ...

Kontributor...

  • Pembimbing 1: Ir. Sapto Prajogo, M.Si.


    Pembimbing 2: Drs. Maridjo, M.T., Editor: Erlin Arvelina

Download...