Path: Top > Tugas Akhir - D3 > 2017 > Jurusan Teknik Mesin > Program Studi Teknik Mesin > 2020
Pengujian Termografi Pada Pompa Sentrifugal Single Stage Dengan Variasi Beban
Thermography Test of Single Stage Centrifugal Pump With Load Variations
Tugas Akhir, 015 / 2020 / TMEUndergraduate Theses from JBPTPPOLBAN / 2021-01-26 11:16:43
Oleh : Gia Arya Putra - 171211015 (giaaryaputra@gmail.com)
Dibuat : 2021-01-26, dengan 4 file
Keyword : #SUBJECT_KEYWORDS#
Pompa sentrifugal di industri merupakan mesin yang memiliki tingkat kritis tinggi, maka perlu dilakukan penerapan pemeliharaan prediktif disamping pemeliharaan berkala. Salah satu teknik pemeliharaan prediktif yang dapat diterapkan untuk memonitor pompa sentrifugal adalah inspeksi penyebaran panas atau termografi. Namun, Informasi penerapan termografi untuk keperluan monitoring kondisi mesin khususnya untuk pompa sentrifugal single stage masih minim dan belum mapan seperti teknik monitoring lainnya. Sehingga diperlukan kajian, pengujian, dan penelitian lebih lanjut. Pengujian termografi dilakukan untuk mengetahui karakteristik penyebaran panas atau temperatur pada pompa sentrifugal single stage dengan menggunakan termografi karena pengaruh beban. Pengujian dilakukan pada 3 variasi beban dengan mengatur tekanan tekan, putaran tetap dengan variasi jam operasi pompa dan tekanan isap tetap. Lama operasi 120 menit dengan pemindaian pertama dilakukan pada waktu operasi 30 menit, selanjutnya dilakukan pemindaian setiap interval waktu 15 menit, yaitu pada operasi 45 menit, 60 menit, 75 menit, 90 menit, 105 menit, dan terakhir 120 menit. Titik â titik pemindaiannya yaitu All Installation (AI), Motor Body (MB), Bearing Motor Drive End (BMDE), Coupling (CPL), Bearing Pump (BPUM), Shaft of Pump (SPUM), Pump Body (PB), dan Reservoir (RES). Hasil pengujian termografi menunjukkan bahwa penyebaran panas terbesar karena pengaruh variasi beban terjadi pada bagian Shaft of Pump sebesar 11,1% pada waktu operasi 120 menit. Temperatur tertinggi terjadi pada bagian Pump Body yaitu mencapai 54,4°C pada tekanan 1,6 bar pada waktu operasi 120 menit. Kondisi komponen Bearing Motor Drive End (BMDE), Bearing Pump (BPUM), dan Motor Body (MB) berdasarkan referensi batas temperatur operasi dinyatakan aman untuk beroperasi.
Deskripsi Alternatif :Centrifugal pumps in industry are machines that have a high critical level, so it is necessary to apply predictive maintenance in addition to periodic maintenance. One of the predictive maintenance techniques that can be applied to monitor centrifugal pumps is heat spread inspection or thermography. However, information on the application of thermography for monitoring machine conditions, especially for single-stage centrifugal pumps, is still minimal and not as well as other monitoring techniques. So that further study, testing and research are needed. Thermography testing is carried out to determine the characteristics of the spread of heat or temperature at a single level centrifugal pump by using thermography because of the influence of the load. Tests carried out on 3 variations of the load by adjusting the compressive pressure, fixed rotation with variations in pump operating hours and fixed suction pressure. The duration of operation is 120 minutes with the first scan performed at the time of operation 30 minutes, then scanning is done at 15 minute intervals, namely at 45 minutes, 60 minutes, 75 minutes, 90 minutes, 105 minutes, and last 120 minutes. The scanning points are All Installation (AI), Motor Body (MB), Motor Drive End Bearing (BMDE), Coupling (CPL), Bearing Pump (BPUM), Shaft of Pump (SPUM), Pump Body (PB), and Reservoir (RES). Thermographic test results show that the greatest heat distribution due to the influence of load variations occurs in the Shaft of Pump section of 11.1% at the operating time of 120 minutes. The highest temperature occurs at the Pump Body section, reaching 54.4 ° C at a pressure of 1.6 bar at 120 minutes of operation. The condition of the components of the Bearing Motor Drive End (BMDE), Bearing Pump (BPUM), and Motor Body (MB) based on the operating temperature limit reference is declared safe to operate.
Beri Komentar ?#(0) | Bookmark
Properti | Nilai Properti |
---|---|
ID Publisher | JBPTPPOLBAN |
Organisasi | |
Nama Kontak | Erlin Arvelina |
Alamat | Jl. Trsn. Gegerkalong Hilir Ds. Ciwaruga |
Kota | Bandung |
Daerah | Jawa Barat |
Negara | Indonesia |
Telepon | 022 201 3789 ext. 168, 169, 239 |
Fax | 022 201 3889 |
E-mail Administrator | erlin.arvelina@polban.ac.id |
E-mail CKO | erlin.arvelina@polban.ac.id |
Print ...
Kontributor...
- Pembimbing 1: Prasetyo, S.T., M.Eng.
Pembimbing 2: Drs. Parno Raharjo, M.Pd., M.Sc., Ph.D., Editor: Muhammad Abdillah Islamy, S.Pd
Download...
File : KELENGKAPAN TA - 171211015.pdf
(425614 bytes)
File : BAB 1 - 171211015.pdf
(372556 bytes)
File : BAB 2 - 171211015.pdf
(954287 bytes)
File : BAB 5 - 171211015.pdf
(255795 bytes)