Path: Top > Tugas Akhir - D3 > Jurusan Teknik Sipil > Program Studi Konstruksi Gedung > 2013

Pengaruh Perubahan Posisi Dinding Geser pada Perencanaan Komponen Sistem Struktur Ganda di Wilayah Gempa 6

The Effect of Shear Wall Position on the Structural Dual System Components Design in the Earthquake Zone 6

Tugas Akhir, 006 / 2013 / KGE
Undergraduate Theses from JBPTPPOLBAN / 2017-02-22 11:49:37
Oleh : Harry Pratama - 091111015 & Arief Permadi Putra - 101111007 (harry.pratama29@gmail.com)
Dibuat : 2017-02-22, dengan 4 file

Keyword : sistem ganda, simpangan horizontal, posisi dinding geser, SRPMK
Subjek : dual system, story drift, shear wall positition, Special Moment-Resisting Frame

Salah satu sistem struktur yang digunakan pada gedung bertingkat di daerah rawan gempa adalah sistem struktur ganda. Pada Tugas Akhir ini menggunakan sistem struktur ganda yang terdiri dari rangka ruang yang memikul beban gravitasi dan pemikul beban lateral berupa dinding geser. Tugas Akhir ini dilakukan studi dan perancangan dengan membandingkan pengaruh perubahan posisi dinding geser terhadap simpangan horizontal. Model gedung yang ditinjau terdiri dari 3 buah model gedung dengan dinding geser yang posisinya berbeda. Perancangan komponen struktur dilakukan pada model gedung dengan simpangan horizontal terkecil dan memenuhi persyaratan kondisi batas layan dan kondisi batas ultimit. Gedung dirancang berdasarkan SNI 03-2847-2002 dan SNI 03-1726-2002. Perancangan tulangan dilakukan dengan konsep Sistem Rangka Pemikul Momen Khusus (SRPMK) dan Sistem Dinding Struktural Khusus (SDSK). Perancangan komponen struktur yang dilakukan dengan menggunakan mutu material beton fc'=30 MPa dan baja BJTP20 dan BJTD40. Dari hasil studi yang dilakukan menunjukan bahwa simpangan horizontal terbesar terjadi pada model gedung 1 sebesar 0,071 m dengan posisi dinding geser tepat ditengah-tengah pusat gedung . Simpangan horizontal terkecil kedua terjadi model gedung 3 dengan posisi dinding geser diletakan 8 meter arah x dari pusat gedung yang memiliki penuruan simpangan sebesar 2,82% dari simpangan model 1. Simpangan horizontal terkecil pertama terjadi pada model gedung 2 dengan posisi dinding geser diletakan 4 meter arah x dari pusat gedung penurunan simpangan sebesar 5,86% dari simpangan model 1. Sehingga model 2 akan diteruskan pada perhitungan penulangan komponen struktur. Untuk memudahkan di lapangan digunakan dimensi balok dan kolom tipikal untuk setiap 3 lantai dari total 9 lantai. Diameter tulangan tidak memiliki banyak variasi yaitu D19 dan D16 untuk tulangan utama dan ø10 untuk tulangan sengkang. Kata kunci: sistem ganda, simpangan horizontal, posisi dinding geser, SRPMK.

Deskripsi Alternatif :

One of the structural system which is used in high-rise building at higher seismic activities area is a structural dual system. In this final project, it was using a structural dual system which is consist of a moment resisting frame and a shear wall structure. The study has been done by design with comparing the effect of the shear wall position towards the storey drift on each storey. Building models which are observed consist of 3 models with different position of shear wall. The design of structural components are applied to building model with smallest drift and already meet with the requirements of serviceability boundary condition and ultimate boundary condition. The code for utilized were namely SNI 03-2847-2002 and SNI 03-1726-2002. Special Moment-Resisting Frame (SMRF) and Special Structural Wall System methods were used to design the reinforcement of upper structures and shear wall structure as well (concrete and steel quality material, namely fc'=30 MPa, BJTP20, and BJTD40). To sum up story drift which is higher occurred in building model 1 was around 0.071 m with shear wall position in the right middle of the center of building. The second lower amount of story drift occurs on building model 3 with shear wall position in X direction is placed 8 m from the center of the building which has decreased slightly by 2,82% from building model 1 drift. The smallest story drift occurs on building model 2 with shear wall position in X direction is placed 4 m from the center of the building which has declined in story value by 5,86 % from building model 1 deviation. Thus building model 2 will be forwarded to the calculation of components structural reinforcement. In order to use easily on applying at the field, dimension of the beam and column structures are typical for every 3 floors from total of 9 floors. The reinforcement gives detail for instance for longitudinal reinforcement D19 and D16, in addition for transversal reinforcement used Ø10. Keywords: dual system, story drift, shear wall positition, Special Moment-Resisting Frame.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakErlin Arvelina
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorerlin.arvelina@polban.ac.id
E-mail CKOerlin.arvelina@polban.ac.id

Print ...

Kontributor...

  • Pembimbing 1: Ir. Susilahadi, M.T.

    Pembimbing 2: Rahmita Sari Rafdinal, S.ST., M.Eng., Editor: Erlin Arvelina

Download...