Path: Top > Tugas Akhir - D3 > Jurusan Teknik Konversi Energi > Program Studi Teknik Konversi Energi > 2013
Kelaikan Instalasi Listrik Tegangan Rendah (Studi Kasus di Perumahan Jalan Candra Wulan No.3 Bandung)
Feasibility of Low Voltage Electrical Installation (Case Study on Residential Candra Wulan Street Numbers 3 Bandung)
Tugas Akhir, 049 / 2013 / TENUndergraduate Theses from JBPTPPOLBAN / 2017-04-11 10:37:57
Oleh : Hersa Irawan - 101711015 (hersairawan@gmail.com)
Dibuat : 2017-04-11, dengan 4 file
Keyword : Kelaikan, Pengujian, Listrik, Instalasi
Subjek : Feasibility, Testing , Electricity, Installation
Pengujian Kelaikan Instalasi Listrik merupakan suatu kegiatan yang dimaksudkan untuk melindungi keselamatan manusia, harta benda,serta instalasi listrik dan lingkungan terhadap bahaya yang timbul akibat listrik dan juga memeriksa instalasi listrik yang terpasang sesuai dengan standar yang telah ditentukan. Pengujian ini dilakukan di daerah Bandung pada perumahan Candra Wulan No 3 daerah Cijawura. Instalasi yang terpasang pada rumah tinggal ini yaitu dengan daya terpasang 2200 VA dengan jumlah titik lampu 12 buah dan stop kontak 12 buah. Hasil dari pemeriksaan instalasi listrik pada rumah tinggal ini yaitu komponen-komponen listrik yang terpasang sudah sesuai dengan standar (PUIL 2000), kabel yang terpasang pada instalasi listrik ini memiliki nilai resistansi isolasi paling rendah 24,5MΩ dan yang tertinggi yaitu 165MΩ, standar untuk resistansi isolasi kabel yaitu lebih besar dari 0,5MΩ (PUIL 2000), jadi resistansi isolasinya memenuhi standar / laik. Resistansi pembumian pada instalasi listrik ini memiliki nilai resistansi sebesar 4Ω, standar untuk resistansi pembumian yaitu kurang dari 50Ω (PUIL 2000), jadi resistansi pembumian memenuhi standar / laik. Polaritas pada saklar, kotak kontak dan fitting lampunya pun sesuai dengan standar (PUIL 2000). Kesinambungan sirkit pada instalasinya pun baik. Namun untuk gambar instalasi yang dilampirkan oleh pihak instalatir tidak lengkap. Setelah dibandingkan hasil dengan standar yang telah ditentukan maka hasil pemeriksaan instalasi pada Perumahan Candra Wulan No 3 Bandung dinyatakan laik operasi dengan catatan agar dilaksanakan penyempurnaan antara lain penamaan tanda jenis penghantar pada one line diagram, penamaan keterangan fungsi bangunan pada denah. Kata Kunci: Kelaikan, Pengujian, Listrik, Instalasi.
Deskripsi Alternatif :Feasibility testing of electrical installations is an activity that intended to protect human safety, properties and electrical installation and the environment against the hazards that was caused by electricity, check the electrical installation that installed in accordance with the standard. This testing is done in Candra Wulan Residence Number 3 Bandung. Installation that was installed is 2200 VA with 12 lamp fitting and 12 socket. The result of electrical installation testing in this residence are electrical components that was installed in accordance with the standard (PUIL 2000), then the cable that was installed on electrical installation has minimum insulation resistance is 24,5MΩ and the maximum is 165MΩ, the standard for cable insulation resistance is greater than 0.5MΩ (PUIL 2000), so the insulation resistance meets the standards / acceptance. Grounding resistance on this electrical installation is 4Ω, which the standard for grounding resistance less than 50Ω (PUIL 2000) , so the grounding resistance meets the standards / acceptance. Polarity of switch, socket and lamp fitting are accordance with standard. Continuity of circuits electrical installation is good. But for installatrion image attached by the installer is incomplete. Having comparedthe result with those standards then the result of installation on Housing Candra Wulan Number 3 Bandung declared with a note-worthy operation carried out improvements such as signs naming the type conductor on one line diagrams, functional descriptions naming the building in plan. Keyword: Feasibility, Testing , Electricity, Installation.
Beri Komentar ?#(0) | Bookmark
Properti | Nilai Properti |
---|---|
ID Publisher | JBPTPPOLBAN |
Organisasi | |
Nama Kontak | Erlin Arvelina |
Alamat | Jl. Trsn. Gegerkalong Hilir Ds. Ciwaruga |
Kota | Bandung |
Daerah | Jawa Barat |
Negara | Indonesia |
Telepon | 022 201 3789 ext. 168, 169, 239 |
Fax | 022 201 3889 |
E-mail Administrator | erlin.arvelina@polban.ac.id |
E-mail CKO | erlin.arvelina@polban.ac.id |
Print ...
Kontributor...
- Pembimbing: Ir. Kholiq Hernawan, M.T., Editor: Erlin Arvelina
Download...
File : DAFTAR - 101711015.pdf
(317298 bytes)
File : BAB 1 - 101711015.pdf
(170629 bytes)
File : BAB 2 - 101711015.pdf
(465830 bytes)
File : BAB 5 - 101711015.pdf
(160884 bytes)