Path: Top > Tugas Akhir - D3 > Jurusan Teknik Refrigerasi dan Tata Udara > Program Studi Teknik Refrigerasi dan Tata Udara > 2013
Rancang Bangun Training Unit Air Conditioner Dplit menggunakan Inverter
Design Training Unit Air Conditioner Split using Inverter
Tugas Akhir 082 / 2013 / RTUUndergraduate Theses from JBPTPPOLBAN / 2017-04-26 11:55:03
Oleh : Hersyam Budiman - 101611050 (hersyambudiman@rocketmail.com)
Dibuat : 2017-04-26, dengan 4 file
Keyword : Air Conditioner, inverter, COP
Subjek : Air Conditioner, inverter, COP
Dengan meningkatnya taraf hidup serta penggunaan konsumsi energi yang semakin meningkat diperlukan solusi yang nyata dalam upaya penghematan energi, dalam hal ini teknologi inverter dapat melakukan penghematan energi pada peralatan rumah tangga, contohnya Air Conditioner (AC) inverter. AC inverter menggunakan kompresor dengan arus searah (DC), berbeda dengan AC non-inverter yang menggunakan kompresor dengan arus bolak-balik (Alternating Current) yang mempunyai kecepatan putaran motor yang konstan, motor DC kompresor mempunyai frekuensi yang dapat diatur oleh inverter, lalu diatur seberapa besar arus listrik yang diberikan kepada kompresor untuk menggerakan kecepatan putaran kompresor. Tujuan pelaksanaan Tugas Akhir ini adalah untuk merancang bangun sebuah AC Split menggunakan inverter dan menghitung seberapa besar COP serta efisiensi dari AC Split inverter. Dari hasil pengujian didapatkan data COPActual sebesar 6,07 dan COPCarnot sebesar 7,62 sehingga diperoleh efisiensi sebesar 79,76%. Kata kunci: Air Conditioner, inverter, COP.
Deskripsi Alternatif :Within increasing the standard of living and increasing of consumption energy needed a real solution for save the energy. In this cases, inverter technology can save the energy for household appliances such as Air Conditioner inverter. Air Conditioner inverter using Direct Current compressor, different with non-inverter Air Conditioner that it using an Alternating Current compressor which has constant motor speed rotation, Direct Current compressor has a frequency can be set by the inverter, then on Air Conditioner inverter there is setting for regulate how much electrical current supplied to compressor for moving rotation speed of compressor. The aim of this final project is to designing up an Air Conditioner Split using inverter and calculating how much COP and efficiency in this system. From data obtained getting a results 6,07 of COPActual and 7,62 of COPCarnot in order to obtain 79,76% of an efficiency. Keywords: Air Conditioner, inverter, COP.
Beri Komentar ?#(0) | Bookmark
Properti | Nilai Properti |
---|---|
ID Publisher | JBPTPPOLBAN |
Organisasi | |
Nama Kontak | Erlin Arvelina |
Alamat | Jl. Trsn. Gegerkalong Hilir Ds. Ciwaruga |
Kota | Bandung |
Daerah | Jawa Barat |
Negara | Indonesia |
Telepon | 022 201 3789 ext. 168, 169, 239 |
Fax | 022 201 3889 |
E-mail Administrator | erlin.arvelina@polban.ac.id |
E-mail CKO | erlin.arvelina@polban.ac.id |
Print ...
Kontributor...
- Pembimbing 1: Ade Suryatman Margana, S.T., M.Eng.
Pembimbing 2: Rudi Rustandi, S.T., M.Eng., Editor: Erlin Arvelina
Download...
File : DAFTAR - 101611050.pdf
(542649 bytes)
File : BAB 1 - 101611050.pdf
(355345 bytes)
File : BAB 2 - 101611050.pdf
(404532 bytes)
File : BAB 5 - 101611050.pdf
(337193 bytes)