Path: Top > Tugas Akhir - D3 > Jurusan Teknik Refrigerasi dan Tata Udara > Program Studi Teknik Refrigerasi dan Tata Udara > 2012

RANCANG BANGUN PROTOTIP SISTEM TATA UDARA UNTUK DUA JENIS RUANGAN YANG BERBEDA TEMPERATUR

DESIGN OF AIR CONDITIONING SYTSEM PROTOTYPE FOR TWO ROOM TYPES WITH TWO ROOM CONDITIONS

Tugas Akhir, 010 / 2012 / RTU
Undergraduate Theses from JBPTPPOLBAN / 2014-06-19 15:42:34
Oleh : Imelda Sasti - 091611039 (imelda.sasti@gmail.com)
Dibuat : 2014-06-19, dengan 4 file

Keyword : sistem tata udara, sistem udara penuh, Air Handling Unit, saluran udara, temperatur, kelembaban relatif dan debit
Subjek : air conditioning system, all air system, air handling unit, ducting, temperatur, relative humidity and flow rate

Penggunaan sistem tata udara semakin hari semakin berkembang. Hampir semua sektor kehidupan membutuhkan sistem tata udara, baik itu untuk hanya untuk kenyaman termal, untuk proses industri maupun proses transportasi. Untuk mengkondisikan udara dengan kapasitas pendinginan yang besar biasa digunakan yaitu pengkondisi udara jenis sentral. Pengkondisi udara jenis sentral memerlukan dua komponen utama yaitu Air Handling Unit dan saluran udara. Pada Tugas Akhir ini dibuat suatu prototip sistem tata udara untuk dua jenis ruangan yang berbeda temperatur dengan ukuran ruangan dingin yang dibuat adalah 40x40x40 (cm) dan ruangan panas 30x30x30 cm. Sistem pendinginan yang digunakan adalah sistem refrigerasi kompresi uap dengan kapasitas pendinginan 105 watt. Besaran-besaran yang dapat diukur yaitu temperatur bola basah dan bola kering, kelembaban relatif dan kecepatan udara. Hasil pengujian alat membuktikan bahwa temperatur ruangan dingin yang dirancang sesuai dengan perancangan yaitu sebesar 24oC dan temperatur ruangan panas yaitu sebesar 35oC dan 45oC. Sedangkan RH ruangan dan debit udara suplai yang terukur tidak sesuai dengan perancangan. Hal ini dikarenakan drainase pada AHU yang tidak baik. Sedangkan debit udara suplai yang terlalu besar dikarenakan kapasitas kipas yang digunakan terlalu besar. RH yang diperoleh sebesar 87,3 % dan 79,2% sedangkan debit yang diperoleh yaitu 56,95 cfm untuk ruangan 1 dan 54,24 cfm untuk ruangan 2, sedangkandebit untuk ruangan 3 diperoleh sebesar 23,05 cfm dan 35,26 cfm. Kata kunci : sistem tata udara, sistem udara penuh, Air Handling Unit, saluran udara, temperatur, kelembaban relatif dan debit.

Deskripsi Alternatif :

The function of air conditioning system increases rapidly. All sectors in human life need air conditioning system. Air conditioning system is not only used for thermal comfort but also for industry processing and transportation. To conditioned the air with large cooling capacity usually use central air conditioning system. Central air conditioning system needs 2 components for handling and distribute the air, they are Air Handling Unit and ducting. This final project is made anair conditioning system prototype for two room types with two different room conditions, cold rooms have dimension on 40x40x40 cm and the other one has 30x30x30 cm. Refrrigeration system that is used in this last project is vapour compression system which has 105 watt cooling load capcity. The measurement parameter that can be measured on this last project are dry and wet bulb temperature, relative humidity and rate of air flow. Test of performance indicate that cold room temperature which measure match with the data of design is about 24oC and hot room temperature are about 35oC or 45oC. While RH and rate of flow supply that measure are not match with data of design. This case is caused by bad drainage and supply fan that is used has too large capacity. RH that is measuredis about 87,3 % and 79,2%, and rate of flow is 56,95 cfm for first room, 54,24 for second room ans the other one has 23,05 cfm or 35,26 cfm. Key word : air conditioning system, all air system, air handling unit, ducting, temperatur, relative humidity and flow rate.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakErlin Arvelina
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorerlin.arvelina@polban.ac.id
E-mail CKOerlin.arvelina@polban.ac.id

Print ...

Kontributor...

  • Pembimbing 1: Ade Suryatman Margana, ST., M.Eng.

    Pembimbing 2: Ir. Andriyanto Setyawan, MT.
    , Editor: Erlin Arvelina

Download...