Path: Top > Tugas Akhir - D3 > Jurusan Teknik Kimia > Program Studi Analis Kimia > 2012

Pengaruh Suhu dan Waktu Penyimpanan Terhadap Stabilitas Kadar Triprolidin HCl dan Pseudoephedrin HCl dalam Sediaan Sirup Obat Flu

Effect of Temperature and Storage Time On Stability of Triprolidine HCl and Pseudoephedrin HCl In Syrup

Tugas Akhir, 013 / 2012 / ANK
Undergraduate Theses from JBPTPPOLBAN / 2013-11-08 09:28:06
Oleh : Indra Pranata Rizal Ramadan - 091431013
Dibuat : 2013-09-30, dengan 4 file

Keyword : Triprolidin HCl, Pseudoephedrin HCl, Suhu, pH, Stabilitas
Subjek : Triprolidine HCl, Pseudoephedrine HCl, temperature, pH, stability

Triprolidin HCl merupakan antihistamin yang bekerja dengan daya kuat dan bekerja mengurangi efek histamin terhadap tubuh dengan cara menghambat reseptor histamin. Peningkatan suhu dapat mempercepat degradasi obat, sehingga dalam penelitian ini dilakukan kajian pengaruh kenaikan suhu terhadap stabilitas kadar suatu bahan aktif obat. Penelitian ini bertujuan untuk mengetahui seberapa jauh pengaruh kenaikan suhu dan waktu penyimpanan terhadap stabilitas kadar Triprolidin HCl didalam sediaan sirup. Penelitian dilakukan terhadap data stabilitas dengan metode kenaikan suhu yaitu 25oC, 30oC dan 40oC yang disimpan selama 3 tahun. Pada penelitian ini sampel yang disimpan selama tiga tahun dan diukur pada bulan ke 1, 3, 6, 9, 12, 24 dan 36 dengan menggunakan KCKT (Kromatografi Cair Kinerja Tinggi) pada panjang gelombang 254 nm. Selain suhu dilakukan juga penelitian terhadap penurunan pH yang terjadi selama proses penyimpanan. Hasil data stabilitas yang disimpan selama tiga tahun menunjukkan bahwa suhu sangat mempengaruhi degradasi dari obat, sehingga dapat disimpulkan bahwa semakin tinggi suhu penyimpanan maka semakin cepat obat yang mengandung Triprolidin HCl terdegradasi. Selain itu, dilakukan juga pembuktian terhadap kadar Triprolidin HCl dan Pseudoephedrin HCl yang terdapat dipasaran, dimana hasil menunjukkan bahwa kadar Triprolidin HCl dan Pseudoephedrin dipasaran memenuhi spesifikasi yang telah ditetapkan yaitu sebesar 92,5%-117,5% untuk Triprolidin HCl dan 90,0%-110,0% untuk Pseudoephedrin HCl, sehingga dapat dikatakan penyimpanan yang dilakukan dipasaran cukup baik. Kata Kunci : Triprolidin HCl, Pseudoephedrin HCl, Suhu, pH, Stabilitas

Deskripsi Alternatif :

Triprolidine HCl is an antihistamine that works with strong power and work to reduce the effects of histamine on the body by blocking histamine receptors. Increasing the temperature can accelerate the degradation of the drug, so that the research conducted to study the influence of temperature increase the stability of an active ingredient content. This study aims to determine how far the influence of rising temperature and storage time on the stability of triprolidine hydrochloride in the dosage levels of syrup. Research conducted on stability data by the method of temperature rise is 25oC, 30oC and 40oC are kept for 3 years. In this study the samples were stored for three years and measured at months 1, 3, 6, 9, 12, 24 and 36 by using HPLC (High Performance Liquid Chromatography) at a wavelength of 254 nm. In addition to temperature are also carried out a study of pH decline that occurred during the storage process. The results of stability data that are stored for three years show that temperature strongly influences the degradation of the drug, so it can be concluded that the higher the storage temperature the faster the drug that contains triprolidine HCl degraded. In addition, conducted on levels of evidence also triprolidine HCl and HCl contained Pseudoephedrin market, where the results showed that levels of triprolidine HCl and Pseudoephedrin market meet established specifications that is equal to 92.5% -117.5% for triprolidine HCl and 90.0 % -110.0% for Pseudoephedrin HCl, so it can be said that the storage market is quite well done. Keywords : Triprolidine HCl, Pseudoephedrine HCl, temperature, pH, stability

Beri Komentar ?#(1) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakErlin Arvelina
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorerlin.arvelina@polban.ac.id
E-mail CKOerlin.arvelina@polban.ac.id

Print ...

Kontributor...

  • Pembimbing 1: Budi Santoso, Drs., Apt., MT. , Editor: Erlin Arvelina

Download...