Evaluasi Kapasitas Penampang Elemen Struktur Kolom Beton Bertulang Bangunan Gedung 9 Lantai
Evaluation Of Cross-Sectional Capacity Of Structural Element Of Reinforced Concrete Column In 9-Story Building
Tugas Akhir, 008 / 2019 / KGEUndergraduate Theses from JBPTPPOLBAN / 2020-04-15 21:26:11
Oleh : Ingeu Siti Nurhaliza - 161111043 & Nida Nurfalah - 161111049 (sningeu@gmail.com)
Dibuat : 2020-04-15, dengan 4 file
Keyword : Kolom eksterior, Kolom interior, Diagram interaksi, Rasio tulangan, Optimalisai penampang
Subjek : Exterior column, interior column, interaction diagram, reinforcement ratio, cross section optimization
Pembangunan sebuah gedung perkantoran 9 lantai dengan konstruksi beton bertulang dilaksanakan dengan dimensi elemen struktur kolom yang sama untuk seluruh elemen-elemen struktur kolom dari lantai dasar sampai lantai 8, baik untuk kolom eksterior maupun kolom interiornya, yaitu 800 mm x800 mm. Hal ini tidak lazim pada perancangan elemen struktur kolom konstruksi beton bertulang. Oleh krena itu, perlu dilakukan optimalisasi penampang elemen-elemen struktur kolom pada gedung tersebut. Perencanaan kolom dilakukan berdasarkan mutu beton 30 MPa sedangkan optimalisasi dilakukan berdasarkan mutu beton eksisting 14 MPa. Optimalisasi penampang elemen-elemen struktur kolom dilakukan dengan dua cara yaitu berdasarkan dimensi dan rasio tulangan kolom. Optimalisasi terhadap dimensi penampang kolom eksisting dilakukan dengan mengubah dimensi penampang kolom yang telah direncanakan dengan rasio yang mendekati 1,59 % ; sedangkan, optimalisasi terhadap rasio tulangan penampang kolom eksisting dilakukan dengan mengubah jumlah dan luas penampang tulangan kolom dengan rasio yang ditentukan yaitu 1-2 %, 2-3 % dan 3-4 %. Hasil studi menunjukkan bahwa optimalisasi terhadap kolom interior dan eksterior menghasilkan dimensi yang bervariasi dari 400 mm x 400 mm sampai 750 x 750 mm dengan incremental 50 mm, dengan melakukan optimalisasi ini dapat menghemat volume beton 35 % sampai 62 % untuk setiap variasi kolom. Kata kunci: Kolom eksterior, Kolom interior, Diagram interaksi, Rasio tulangan, Optimalisai penampang.
Deskripsi Alternatif :The construction of a 9-storey office building with reinforced concrete construction is carried out with the same dimensions of column structure elements for all column structure elements, from the ground floor to the 8th floor, both for the exterior column and the interior column, which is 800 mm x800 mm. This is not unusual in the design of reinforced concrete construction column structure elements. Therefore, it is necessary to optimize the cross section of column structural elements in the building. Column planning is carried out based on 30 MPa concrete quality while optimization is done based on 14 MPa existing concrete quality. Optimization of column structural elements cross section is carried out in two ways, based on the dimensions and ratio of column reinforcement. Optimization of the existing column dimensions is done by changing the planned dimensions of the column section with a ratio that is close to 1.59%; whereas, the optimization of the existing column cross section reinforcement ratio is done by changing the number and cross-sectional area of the column with a specified ratio of 1-2%, 2-3% and 3-4%. The results of the study show that optimization of interior and exterior columns produces dimensions that vary from 400 mm x 400 mm to 750 x 750 mm with incremental 50 mm, by optimizing this can save concrete volume 35% to 62% for each column variation. Keywords: Exterior column, interior column, interaction diagram, reinforcement ratio, cross section optimization.
Beri Komentar ?#(0) | Bookmark
Properti | Nilai Properti |
---|---|
ID Publisher | JBPTPPOLBAN |
Organisasi | |
Nama Kontak | Erlin Arvelina |
Alamat | Jl. Trsn. Gegerkalong Hilir Ds. Ciwaruga |
Kota | Bandung |
Daerah | Jawa Barat |
Negara | Indonesia |
Telepon | 022 201 3789 ext. 168, 169, 239 |
Fax | 022 201 3889 |
E-mail Administrator | erlin.arvelina@polban.ac.id |
E-mail CKO | erlin.arvelina@polban.ac.id |
Print ...
Kontributor...
- Pembimbing: Dr. Mardiana Oesman, BSCE., M.T., Editor: Erlin Arvelina
Download...
File : KELENGKAPAN TA - 161111043 & 161111049.pdf
(2627632 bytes)
File : BAB 1 - 161111043 & 161111049.pdf
(177011 bytes)
File : BAB 2 - 161111043 & 161111049.pdf
(494323 bytes)
File : BAB 5 - 161111043 & 161111049.pdf
(177190 bytes)