Pengaturan TXV Untuk Mendapatkan Kinerja Siklus Kompresi Uap yang Maksimal
Setting TXV To Get Maximum Performance Of Vapor Compression Cycle
Tugas Akhir, 011 / 2014 / TENUndergraduate Theses from JBPTPPOLBAN / 2018-04-05 11:48:49
Oleh : Irene Deby Palupi - 111711041 (irenedeby@gmail.com)
Dibuat : 2018-04-05, dengan 4 file
Keyword : TXV, katup ekspansi, COP, efek refrigerasi, kerja kompresor
Subjek : TXV, expansion valve, COP, refrigeration effect, work of compressor
TXV merupakan komponen siklus kompresi uap yang berfungsi untuk mengubah tekanan refrigeran dari refrigeran bertekanan tinggi menjadi refrigeran bertekanan rendah. Selain itu, TXV juga berfungsi untuk mengatur laju aliran refrigeran yang akan masuk ke evaporator sesuai dengan beban pendinginan yang akan dilayani oleh evaporator. Dalam penelitian ini dilakukan pengujian mengenai pengaruh pengaturan Thermostatic Expansion Valve (TXV) pada alat refrigeran trainer dengan kapasitas 0,5 pK. Pengujian ini bertujuan untuk mengetahui pengaruh pengaturan TXV terhadap kinerja siklus kompresi uap. Pengujian ini dilakukan dengan melakukan penyetelan pada skrup adjuster TXV. Penyetelan skrup adjuster ini dilakukan dengan 4 variasi kondisi yaitu, dikencangkan dengan cara diputar penuh searah jarum jam, 3 putaran berlawanan arah jarum jam, 5 putaran berlawanan arah jarum jam, dan dikendorkan dengan cara diputar penuh berlawanan arah jarum jam. Pengujian ini dilakukan di Laboratorium Jurusan Teknik Konversi Energi Politeknik Negeri Bandung. Hasil pengujian menunjukkan bahwa pengaturan pada TXV memberikan pengaruh pada kinerja dari sistem tersebut. Memutar skrup adjuster berlawanan dengan arah jarum jam (mengendorkan) menyebabkan efek refrigerasi, kerja kompresor, dan Coefficient Of Performance (COP) semakin meningkat, sedangkan memutar skrup adjuster searah dengan jarum jam (mengencangkan) menyebabkan efek refrigerasi, kerja kompresor, dan Coefficient Of Performance semakin menurun. Kata kunci: TXV, katup ekspansi, COP, efek refrigerasi, kerja kompresor.
Deskripsi Alternatif :TXV is a component of the vapor compression cycle that serves to change pressure of refrigerant from high pressure refrigerant into the low-pressure refrigerant. In addition, expansion valve also serves to regulate flow rate of refrigerant that will enter the evaporator according to the cooling load to be served by evaporator. This research discuss about effect of setting Thermostatic Expansion Valve (TXV) on the appliance refrigerant trainer 0,5 pK. The goals of this test is to determine effect of setting TXV to performance of vapor compression cycle.The test is performed by adjusting the screw adjuster TXV. Adjuster screw adjustment is done with 4 variations of conditions, namely, fully tightened by twisting clockwise, 3 turns anticlockwise, 5 turns counter-clockwise, and loosened by means of fully rotated counter-clockwise. Testing was conducted at the Laboratory of Energy Conversion Engineering Department Bandung State Polytechnic. The test results indicate that the settings TXV give an effect to performance of the system. Rotate the adjuster screw counter-clockwise (loosen) causes the refrigeration effect, work of compressor, and Coefficient Of Performance (COP) is increasing, while turning the adjuster screw clockwise (tightening) causes the refrigeration effect, compressor work, and Coefficient Of Performance decreases. Keywords: TXV, expansion valve, COP, refrigeration effect, work of compressor.
Beri Komentar ?#(0) | Bookmark
Properti | Nilai Properti |
---|---|
ID Publisher | JBPTPPOLBAN |
Organisasi | |
Nama Kontak | Erlin Arvelina |
Alamat | Jl. Trsn. Gegerkalong Hilir Ds. Ciwaruga |
Kota | Bandung |
Daerah | Jawa Barat |
Negara | Indonesia |
Telepon | 022 201 3789 ext. 168, 169, 239 |
Fax | 022 201 3889 |
E-mail Administrator | erlin.arvelina@polban.ac.id |
E-mail CKO | erlin.arvelina@polban.ac.id |
Print ...
Kontributor...
- Pembimbing: Bambang Puguh Manunggal, S.T., M.Eng., Editor: Erlin Arvelina
Download...
File : DAFTAR - 111711041.pdf
(562735 bytes)
File : BAB 1 - 111711041.pdf
(313451 bytes)
File : BAB 2 - 111711041.pdf
(744538 bytes)
File : BAB 5 - 111711041.pdf
(245738 bytes)