Path: Top > Skripsi - D4 > 2017 > Jurusan Teknik Konversi Energi > Program Studi Teknologi Pembangkit Tenaga Listrik > 2017
Rancangan Sistem Multi Stage Flash Tipe Brine Circulation Untuk PLTU Kapasitas 3x315 MW
Design of Brine Circulation Type Multi Stage Flash System for 3x315 MW Steam Power Plant
Tugas Akhir, 011 / 2017 / TPTLUndergraduate Theses from JBPTPPOLBAN / 2018-09-03 15:05:20
Oleh : Izhhar Kamaluddin - 131724013 (izhhark18@gmail.com)
Dibuat : 2017-12-07, dengan 4 file
Keyword : air, desalinasi, kondensasi, MSF-BC, PLTU
Subjek : water, desalination, condensation, MSF-BC, steam power plant
Multi Stage Flash Desalination tipe Brine Circulation (MSF-BC) merupakan salah satu teknologi desalinasi yang memanfaatkan panas thermal pada sistem pengolahan air untuk pembangkit yang digunakan sebagai pretreatment dengan pemurnian air laut menjadi air tawar. Pada rancangan ini dibahas kriteria rancangan MSF-BC yang dapat memenuhi kebutuhan air pembangkit PLTU 3x315 MW dengan kebutuhan air sebesar 130 m3/jam. MSF-BC bekerja dengan prinsip penguapan air laut lalu uap air laut dikondensasi dan menghasilkan produk berupa distilat. Rancangan dimulai dengan menentukan parameter awal rancangan yaitu data air laut dan data dari jurnal referensi. Kemudian dilakukan perhitungan neraca massa dan energi, perpindahan panas, dan parameter performa menggunakan Performance Ratio (PR). Pemodelan matematika yang digunakan adalah hasil pengembangan oleh El-Dessouky dan Ettouney (2002). Dari perhitungan didapatkan Temperature Difference tiap stage adalah 4,50⁰C dengan luas area perpindahan panas sebesar 5154,2 m2 dan produk distilat yang dihasilkan sebesar 131,42 ton/jam. Spesifikasi pipa yang digunakan menggunakan material Copper Nickel 90-10 dengan diameter luar pipa 25,4 mm, panjang pipa 2,22 m, dan jumlah pipa pada heat recovery stage sebanyak 2.240 buah dengan 9 stage sedangkan pada bagian heat rejection stage sebanyak 3.060 buah dengan 3 stage. PR yang dihasilkan adalah sebesar 4,4. Dari hasil analisis diketahui bahwa kenaikan top brine temperature akan berdampak terhadap jumlah penggunaan steam, sehingga mempengaruhi terhadap nilai Performance Ratio nya. Kinerja sistem MSF-BC sangat dipengaruhi oleh jumlah laju steam yang digunakan. Kata kunci: air, desalinasi, kondensasi, MSF-BC, PLTU.
Deskripsi Alternatif :Multi Stage Flash Desalination Brine Circulation type (MSF-BC) is one of desalination technology that utilizes thermal heat in water treatment system for power plant which is used as pretreatment with purification of sea water into fresh water. In this design, the MSF-BC design criteria are covered which can fulfill the water requirement of 3x315 MW steam power plant with water requirement of 130 m3 /h. MSF-BC works on the principle of evaporation of seawater and condensed seawater vapor and produces a product of distillate. The design starts with determining the initial design parameters ie sea water data and data from reference journals. Then calculated mass balance and energy, heat transfer, and performance parameters using Performance Ratio (PR). The mathematical modeling used was the result of development by El-Dessouky and Ettouney (2002). From the calculation obtained Temperature Difference each stage is 4.50⁰C with the area of heat transfer of 5154.2 m2 and distillate products produced for 131.42 t/h. The specifications of pipe used are Copper Nickel 90-10 material with outside diameter of 25.4 mm pipe, 2.22 m pipeline length, and number of pipes in heat recovery stage of 2,240 units with 9 stages while in heat rejection stage 3,060 units with 3 stages. The resulting PR is 4,4. From the analysis it is known that the increase of top brine temperature will affect the amount of steam usage, thus affecting the value of its Performance Ratio. The performance of the MSF-BC system is strongly influenced by the amount of steam rate used. Keywords: water, desalination, condensation, MSF-BC, steam power plant.
Beri Komentar ?#(0) | Bookmark
Properti | Nilai Properti |
---|---|
ID Publisher | JBPTPPOLBAN |
Organisasi | |
Nama Kontak | Erlin Arvelina |
Alamat | Jl. Trsn. Gegerkalong Hilir Ds. Ciwaruga |
Kota | Bandung |
Daerah | Jawa Barat |
Negara | Indonesia |
Telepon | 022 201 3789 ext. 168, 169, 239 |
Fax | 022 201 3889 |
E-mail Administrator | erlin.arvelina@polban.ac.id |
E-mail CKO | erlin.arvelina@polban.ac.id |
Print ...
Kontributor...
- Pembimbing 1: Ir. Sri Wuryanti, M.Si.
Pembimbing 2: Drs. Maridjo, M.T., Editor: Erlin Arvelina
Download...
File : KELENGKAPAN TA - 131724013.pdf
(935803 bytes)
File : BAB 1 - 131724013.pdf
(105241 bytes)
File : BAB 2 - 131724013.pdf
(763539 bytes)
File : BAB 5 - 131724013.pdf
(97651 bytes)