Rancang Bangun Otomatis Kontrol Perbaikan Faktor Daya pada Beban Listrik Dinamis 1 Fasa

Design Automatic Control Power Factor Correction For Dinamic Elektrik Load 1 Phase

Tugas Akhir, 011 / 2012 / TEN
Undergraduate Theses from JBPTPPOLBAN / 2017-04-11 10:03:22
Oleh : Jajang Nurjaman Annazwa - 091711019 (mulky_annazwa@hotmail.com)
Dibuat : 2014-07-18, dengan 3 file

Keyword : Otomatis Kontrol Faktor Daya, Sensor Arus, Zero Crossing Detektor, Mikrokontroller, Driver
Subjek : Automatic Control Power Factor, Curent Sensor, Zero Crossing Detektor, Mikrokontroller, Driver

Sistem control otomatis perbaikan faktor daya pada beban listrik dinamis 1 fasa merupakan salahsatu dari banyak system control otomatis yang digunakan untuk aplikasi control listrik. Hasil dari perancangan system ini yaitu dapat melakukan perbaikan faktor daya secara otomatis dengan cara mendeteksi perbedaan fasa antara arus dan tegangan yang terjadi pada system yang digunakan. Dengan menggunakan alat ini maka faktor daya akan dijaga dengan nilai mendekati 1 dan kemudian data hasil dari perbaikan tersebut dapat dilihat pada LCD. Alat ini dirancang untuk beban yang bersifat induktif, dan system ini dapat memperbaiki nilai faktor daya dari 0,6 menjadi 0,97 lagging. Alat ini memiliki spesifikasi 4400 VA, 220 volt, 1 Fasa. Kerja dari system control ini dengan membandingkan nilai set point dengan input ADC pada mikrokontroller. Apabila nilai input ADC melebihi nilai set point, maka mikrokontroller akan memberikan isyarat kepada driver agar memutus kapasitor kompensator sehingga tidak mengalirkan arus dan tegangan pada kapasitor kompensator yang dipasang parallel dengan beban, karena jika tidak segera diputus maka beban akan menjadi kapasitif yang dapat menaikan tegangan sehingga akan membahayakan bagi peralatan elektronik karena terjadi lonjakan tegangan pada saluran. Kata Kunci : Otomatis Kontrol Faktor Daya, Sensor Arus, Zero Crossing Detektor, Mikrokontroller, Driver.

Deskripsi Alternatif :

Automatic control system power factor correction for a dynamic electric load is one of the main 1 phase of many automatic control system that is used for power control applications. The results of the design of this system can perform automatic power factor correction by detecting the phase difference between current and voltage that occurs for system used. By using this tool it will be kept by the power factor value close to 1 and then the data is the result of these correction can be seen for LCD. The tool is designed for the load is inductive, and this system can improve the power factor of 0.6 to 0.97 lagging. This device has a specification 4400 VA, 220 volt, 1 phase. Perform of this control system by comparing the set point value by the ADC input for microcontroller. If the ADC input value exceeds the set point, then the microcontroller will give a signal to the driver to break the compensator so as not to drain the capacitor current and voltage on the capacitor compensator is mounted parallel with the load, because if not immediately disconnected it will be a capacitive load can increase the voltage so would be harmful to electronic equipment due to voltage spikes for system. Keyword : Automatic Control Power Factor, Curent Sensor, Zero Crossing Detektor, Mikrokontroller, Driver.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakErlin Arvelina
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorerlin.arvelina@polban.ac.id
E-mail CKOerlin.arvelina@polban.ac.id

Print ...

Kontributor...

  • Pembimbing 1: Aceng Daud, M.Eng., Editor: Erlin Arvelina

Download...