Path: Top > Tugas Akhir - D3 > Jurusan Teknik Refrigerasi dan Tata Udara > Program Studi Teknik Refrigerasi dan Tata Udara > 2012
Rancang Bangun Heat Exchanger Tipe Shell and Coil pada Dispenser sebagai Alat Penghematan Energi
Design of Shell and Coil Heat Exchanger for Saving Energy Dispenser
Tugas Akhir, 034 / 2012 / RTUUndergraduate Theses from JBPTPPOLBAN / 2014-07-04 10:27:14
Oleh : Jatining Wiwaha - 091611042 (jatiningwiwaha@gmail.com)
Dibuat : 2014-07-04, dengan 4 file
Keyword : Sistem Refrigerasi Kompresi Uap, preheat, penghematan energi
Subjek : refrigeration system, preheat, saving energy
Dispenser air minum hot and cool adalah salah satu alat yang menggunakan sistem refrigerasi kompresi uap yang pengaplikasiannya dimana mana mulai dari rumah sampai kantor-kantor. Namun tanpa disadari dispenser membutuhkan daya listrik yang besar berasal dari sistem pemanas air yang bisa mencapai 300W. Pada saat sistem refrigerasi beroperasi maka kondenser menjadi panas, panas kondenser ini dapat dimanfaatkan sebagai proses pemanasan awal air atau preheat. Dalam tugas akhir ini penulis memodifikasi dispenser dengan penambahan tangki air preheat dan penambahan panjang pipa kondenser sebagai pipa preheat. Sehingga dalam prosesnya nanti refrigeran keluaran kompresor akan masuk ke kondenser 1 atau pipa preheat lalu masuk ke kondenser 2 sebagai kondeser yang menbuang panas ke lingkungan, setelah itu masuk ke alat ekspansi dan evaporator. Maka ketika air dari tangki air dingin masuk tangki preheat akan dipanaskan oleh kondenser 1 sehingga pada saat keluar dari tangki preheat air menjadi hangat dan pada saat masuk ke heater sudah hangat sehingga waktu yang dibutuhkan heater untuk proses pemanasan akan menjadi lebih singkat dan pada akhirnya akan menjadi proses penghematan energi. Dari data yang telah diambil maka penulis dapat melakukan penghematan sekitar 0.51 kWh dalam 24 jam Kata Kunci : Sistem Refrigerasi Kompresi Uap, preheat, penghematan energi
Deskripsi Alternatif :Water dispenser hot and cool is one tools which using refrigeration system which implementation use in every where start from little house until big office. But without aware dispenser need big energy from electric heater which reach 300 Watt. In the running system temperature in condenser is hot, So this system can be used for preheat. In this final project writer make modification with using additional tank preheat and make condenser pipe is longer. So the system is start from refrigerant out compressor come in to first condenser as preheat and then come to the real condenser for reject the heat to area and then to capillary tube and the last to evaporator. So when water from water tank come in to preheat tank will be proceed to hot by condenser 1 so when water come to heater tank water already hot caused electric heater is save energy. From data which taken so writer can saving energy around 0.51 kWh in 24 hours. Key Word : refrigeration system, preheat, saving energy
Beri Komentar ?#(0) | Bookmark
Properti | Nilai Properti |
---|---|
ID Publisher | JBPTPPOLBAN |
Organisasi | |
Nama Kontak | Erlin Arvelina |
Alamat | Jl. Trsn. Gegerkalong Hilir Ds. Ciwaruga |
Kota | Bandung |
Daerah | Jawa Barat |
Negara | Indonesia |
Telepon | 022 201 3789 ext. 168, 169, 239 |
Fax | 022 201 3889 |
E-mail Administrator | erlin.arvelina@polban.ac.id |
E-mail CKO | erlin.arvelina@polban.ac.id |
Print ...
Kontributor...
- Pembimbing 1: Ir. Windy Hermawan Mitrakusuma, MT.
Pembimbing 2: Rudi Rustandi, ST., M.Eng.
, Editor: Erlin Arvelina
Download...
File : DAFTAR - 091611042.pdf
(342875 bytes)
File : BAB 1 - 091611042.pdf
(237151 bytes)
File : BAB 2 - 091611042.pdf
(591784 bytes)
File : BAB 6 - 091611042.pdf
(323379 bytes)