Path: Top > Jurnal Ilmiah > Jurusan Teknik Sipil

Perencanaan Struktur Bawah Pada Gedung Fakultas Pendidikan UPI Kota Bandungdengan Menggunakan PiledraftEkonomi dan Bisnis

Design Substructure of UPI Faculty of Economics and Bussiness Education Building in Bandung City Using a Piledraft

Journal from JBPTPPOLBAN / 2023-08-16 14:16:52
Oleh : Javi Sabar Islami ; Naufal Abdu Elfitri ; Agus Suyono (agus.suyono@polban.ac.id)
Dibuat : 2023-08-16, dengan 1 file

Keyword : Piled Raft, Design, Bearing
Subjek : Piled Raft, Perancangan, Penurunan

Lokasi sekitar bangunan gedung FPEB UPI Bandung setelah dilakukan penyelidikan tanah didapatkan hasil bahwa kondisi tanah tersebut merupakan tanah lunak. Dengan kondisi tersebut maka perlu direncanakan suatu fondasi yang memiliki daya dukung cukup dan mampu mengatasi penurunan yang terjadi hingga sekecil mungkin. Berdasarkan kondisi tersebut, dilakukan perancangan struktur bawah menggunakan fondasi piled raft. Fondasi piled raft ini merupakan gabungan dari fondasi rakit (raft) dengan fondasi tiang bor (bored pile). Fondasi rakit bekerja untuk melakukan distribusi beban yang diterima secara merata serta fondasi bored pile bekerja untuk menambah daya dukung, menyebar beban ke tanah keras, dan mereduksi penurunan yang terjadi sesuai dengan SNI 8460:2017 mengenai Persyaratan Perancangan Geoteknik. Perancangan ini dimulai dengan merencanakan fondasi piled raft berdasarkan data penyelidikan tanah (N-SPT) sesuai dengan beban yang akan diterima oleh struktur bawah. Dari hasil perencanaan, didapatkan fondasi raft dengan tebal 1,2 meter yang memiliki daya dukung sebesar 57,766 kN/m2, serta didapatkan diameter bored pile 0,6 meter pada kedalaman 30 meter dengan daya dukung tiang sebesar 1846,231 kN. Penurunan fondasi yang terjadi sebesar 7,42 cm dan defleksi tiang sebesar 11,8 mm yang mana keduanya memenuhi persyaratan yang diizinkan berdasarkan SNI 8460:2017 mengenai Persyaratan Perancangan Geoteknik. Kata Kunci: Piled Raft, Perancangan, Penurunan.

Deskripsi Alternatif :

The location around the FPEB UPI Bandung building after conducting a soil investigation showed that the soil condition was soft soil. Under these conditions, it is necessary to plan a foundation that has sufficient bearing capacity and is able to overcome the settlement that occurs as small as possible. Based on these conditions, the design of the lower structure was carried out using piled raft foundations. Piled raft foundation is a combination of raft foundation with drilled pile foundation. The raft foundation works to distribute the received load evenly and the bored pile foundation works to increase the carrying capacity, spread the load onto hard soil, and reduce settlements that occur in accordance with SNI 8460: 2017 concerning Geotechnical Design Requirements. This design begins with planning the piled raft foundation based on soil investigation data (N-SPT) according to the load that will be received by the substructure. From the planning results, obtained a raft foundation with a thickness of 1.2 meters which has a carrying capacity of 57.766 kN/m2, and obtained a bored pile diameter of 0.6 meters at a depth of 30 meters with a pile carrying capacity of 1846.231 kN. The settlement of the foundation that occurred was 7.42 cm and the pile deflection was 11.8 mm, both of which met the requirements permitted under SNI 8460:2017 concerning Geotechnical Design Requirements. Keywords: Piled Raft, Design, Bearing.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakErlin Arvelina
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorerlin.arvelina@polban.ac.id
E-mail CKOerlin.arvelina@polban.ac.id