Path: Top > Tugas Akhir - D3 > Jurusan Teknik Elektro > Program Studi Teknik Listrik > 2012
RANCANG BANGUN HMI MASTER CONTROL UNIT (MCU) SISTEM SCADA SIMULATOR PLTMH
DESIGN AND IMPLEMENTATION HMI MASTER CONTROL UNIT (MCU) SCADA SYSTEM PLTMH SIMULATOR
Tugas Akhir, 042 / 2012 / TLIUndergraduate Theses from JBPTPPOLBAN / 2015-11-18 09:21:48
Oleh : Lufty Restu Ramadhan - 091321054
Dibuat : 2013-05-07, dengan 4 file
Keyword : SCADA, RTU, HMI, Visual Basic 6.0, Telecontroling, Telesignaling ,Telemetering,RS232
Subjek : SCADA, RTU, HMI, Visual Basic 6.0, Telecontroling, Telesignaling, Telemetering, RS232
Seiring berkembangnya teknologi, kebutuhan manusia akan tenaga listrik pun ikut berkembang. Untuk menunjang kebutuhan tersebut maka suplai energi listrik harus mempunyai sistem dengan keandalan, kontinuitas dan kualitas yang baik pada sisi beban maupun sumber. Dengan menerapkan Supervisory Control And Data Acquisition (SCADA) yang merupakan sebuah sistem pengawasan, pengendalian dan proses akuisisi data adalah solusi tepat untuk melakukan fungsi kerja tersebut. Penggunaan sistem SCADA pada pembangkit listrik menjadi sangat tepat guna mengurangi gangguan serta meminimalkan waktu pemeliharaan jika suatu saat terjadi gangguan. Oleh karena itu, pada penyusunan proyek akhir ini, penulis membuat HMI Master Control Unit SCADA pada pembangkit listrik mikro hidro (PLTMH) berbasis Visual Basic 6.0 guna meningkatkan keandalan sistem. Beberapa besaran di plant diukur secara remote seperti tegangan, frekuensi, suhu, kecepatan dan arus. Kemudian direkam kedalam bentuk database di MS-Excel. Untuk pengujian sistem dilakukan terhadap salah satu plant RTU generator menggunakan komunikasi serial USB downloader RS232 ke serial ATMega16 RTU. Dari pengujian tersebut dapat disimpulkan bahwa secara keseluruhan HMI ini bisa melakukan proses telecontrolling ,telesignaling dan telemetering walaupun terkadang masih terjadi gangguan komunikasi seperti perubahan jalur komunikasi ketika sistem sedang online. Kata kunci: SCADA, RTU, HMI, Visual Basic 6.0, Telecontroling, Telesignaling ,Telemetering,RS232
Deskripsi Alternatif :Along with the development of technology, human power needed also evolved. To support these needs, the supply of electrical energy must have good systems with reliability, continuity and quality on the side of the load nor sources. By applying Supervisory Control And Data Acquisition (SCADA) which is a system of supervision, control and data acquisition process is the best solution to perform work functions.
The use of the SCADA system in the power plant to be very precise in order to reduce distractions and minimize maintenance time if a time of disorder. Therefore, in drafting this final project, the author makes HMI SCADA Master Control Unit on micro-hydro power plant (PLTMH) based on Visual Basic 6.0 -in order to increase the reliability of the system. Some quantities in plant measured remotely like voltage, frequency, temperature, speed and flow. Then recorded into database form in MS-Excel.
Testing system is performed against one of the plant's RTU generator using communication serial RS232 to USB downloader serial RTU ATMega16. From testing it can be inferred that overall this HMI process can perform telemetering, telecontrolling and telesignaling though sometimes still occurs as communication interruption of communication lines change when the system is online
Key word : SCADA, RTU, HMI, Visual Basic 6.0, Telecontroling, Telesignaling, Telemetering, RS232
Beri Komentar ?#(0) | Bookmark
Properti | Nilai Properti |
---|---|
ID Publisher | JBPTPPOLBAN |
Organisasi | |
Nama Kontak | Erlin Arvelina |
Alamat | Jl. Trsn. Gegerkalong Hilir Ds. Ciwaruga |
Kota | Bandung |
Daerah | Jawa Barat |
Negara | Indonesia |
Telepon | 022 201 3789 ext. 168, 169, 239 |
Fax | 022 201 3889 |
E-mail Administrator | erlin.arvelina@polban.ac.id |
E-mail CKO | erlin.arvelina@polban.ac.id |
Print ...
Kontributor...
- Pembimbing 1: Yusuf Sofian, ST., MT.
Pembimbing 2: Teddi Hariyanto, ST., MT. , Editor: Erlin Arvelina
Download...
File : DAFTAR - 091321054.pdf
(337774 bytes)
File : BAB 1 - 091321054.pdf
(180081 bytes)
File : BAB 2 - 091321054.pdf
(723084 bytes)
File : BAB 5 - 091321054.pdf
(173406 bytes)