Rancangan Auxiliary Cooling Water Pump Untuk PLTP Kapasitas 55 MW

The Design of Auxiliary Cooling Water Pump for 55 MW Geothermal Power Plant

Tugas Akhir, 012 / 2017 / TPTL
Undergraduate Theses from JBPTPPOLBAN / 2018-09-03 15:05:20
Oleh : Lutfhi Arif Fadillah - 131724015 (kiimluthfy22@gmail.com)
Dibuat : 2017-12-07, dengan 4 file

Keyword : Pompa sentrifugal, PLTP, Impeller, Head, Titik operasi pompa
Subjek : Centrifugal pump, PLTP, Impeller, Head, Pump operating point

Auxiliary cooling water pump adalah peralatan di PLTP yang digunakan untuk menyediakan air pendingin untuk inter dan after condenser. Dimana di dalam inter dan after condenser akan terjadi proses kondensasi untuk mendinginkan NonCondensable Gas (NCG). Proses kondensasi ini dilakukan agar NCG yang akan dibuang ke lingkungan dalam kondisi bersih dan kering, sehingga tidak mencemari lingkungan. Rancangan pompa diawali dengan mengumpulkan data-data awal dari studi lapangan serta melakukan simulasi menggunakan software Cycle Tempo 5.0 yang kemudian data hasil simulasi digunakan sebagai parameter awal perancangan pompa. Pompa yang dirancang harus mampu mempompakan air dengan kapasitas 552 m3/h. Setelah itu, dilakukan rancangan pompa yang meliputi pemilihan jenis pompa, menghitung dimensi impeller, casing dan poros serta melakukan analisis terhadap pompa yang telah dirancang. Pompa yang dirancang adalah jenis pompa sentrifugal satu tingkat yang memiliki tekanan sebesar 2 bar dengan kapasitas pemompaan 602,7 m3/h. Pompa tersebut bekerja pada putaran 980 rpm dengan head sistem pompa 37 m, daya pompa 71 kW dan efisiensi pompa sebesar 85% Kata kunci: Pompa sentrifugal, PLTP, Impeller, Head, Titik operasi pompa.

Deskripsi Alternatif :

Auxiliary cooling water pump are equipment in the geothermal power plant used to provide cooling water for inter and after condenser. Where in the inter and after condenser there will be condensation process to cool the Non Condensable Gas (NCG). This condensation process aims to clean and dry the NCG before the NCG is discharged into the environment, so NCG does not pollute the environment. The pump design began with collecting initial data from field studies and simulation using Cycle Tempo 5.0 software. Simulation result data is used as initial parameter of pump design. The pump designed should provide the water with 552 m3 / h capacity. After that, choosing the type of pump, calculate the dimensions of the impeller, casing and shaft and also perform analysis of the pump that has been designed. The designed pump is a type of single-stage centrifugal pump with 602,7 m3/h capacity . The pump operate at 980 rpm with 37 m pump head system, 71 kW of pump power and 85% of pump efficiency. Keywords: Centrifugal pump, PLTP, Impeller, Head, Pump operating point.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakErlin Arvelina
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorerlin.arvelina@polban.ac.id
E-mail CKOerlin.arvelina@polban.ac.id

Print ...

Kontributor...

  • Pembimbing 1: Rusmana, S.ST., M.Eng.


    Pembimbing 2: Drs. Maridjo, M.T., Editor: Erlin Arvelina

Download...