Path: Top > Tugas Akhir - D3 > Jurusan Teknik Konversi Energi > Program Studi Teknik Konversi Energi > 2016

Efektivitas Sistem Pencahayaan Berbasis Kerja Presisi Di PT Dirgantara Indonesia

Effectiveness of Lighting System Based on Precision Working at Indonesian Aerospace Inc.

Tugas Akhir, 021 / 2016 / TEN
Undergraduate Theses from JBPTPPOLBAN / 2017-09-27 11:42:23
Oleh : Luthfi Asshidiqi - 131711064 (luthfi.asshidiqi94@gmail.com)
Dibuat : 2017-09-27, dengan 4 file

Keyword : udit energi, tingkat pencahayaan ruang, tingkat pencahayaan kerja, penghematan energi
Subjek : energy audits, level of room lighting, level of work lighting, energy savings

Sistem pencahayaan pada suatu industri kerja presisi erat kaitannya dengan keselamatan, ketelitian dan produktivitas kerja. Sistem pencahayaan yang sesuai dengan standar akan mampu meningkatkan ketelitian dan produktivitas kerja. PT Dirgantara Indonesia merupakan industri yang memiliki kerja presisi didalamnya. Dari pengukuran yang dilakukan, tingkat pencahayaan kerja pada Hangar Assy Fix Wing di PT Dirgantara Indonesia merupakan tempat kerja presisi dilakukan adalah sebesar 237,5 lux untuk Hangar Assy Fix Wing I dan 287,2 lux untuk Hangar Assy Fix Wing II. Nilai tersebut masih dibawah standar, yaitu 300-750 lux (UNEP,2006). Oleh karena itu, perlu dilakukan kegiatan audit untuk meningkatkan kualitas tingkat pencahayaan agar sesuai dengan standar. Adapaun metode yang digunakan adalah metode lumen untuk menentukan tingkat pencahayaan ruang dan metode titik untuk menentukan tingkat pencahayaan kerja. Alternatif yang dapat dilakukan, untuk meningkatkan kualitas tingkat pencahayaan pada lampu existing adalah dengan penggantian lampu existing jenis LED TSTF-400FL atau penggantian dengan lampu sodium bertekanan tinggi (HPS), Master SON-T PIA Plus E E40. Sedangkan untuk lampu tambahan, didapatkan peluang penghematan energi dengan penggantian lampu jenis LED tube 11.5. Perbaikan dengan penggantuan TSTF-400FL dapat meningkatkan tingkat pencahayaan hingga 347 lux dengan investasi sebesar Rp1.086.470.000,00. Sedangkan penggantian lampu dengan jenis HPS hanya akan menghasilkan tingkat pencahayaan sebesar 491 lux dan membutuhkan investasi sebesar Rp50.948.490,00. Sedangkan penggantian lampu tambahan untuk menunjang tingkat pencahayaan kerja dengan jenis LED tube 11.5 akan memberikan penghematan energi sebesar 1609,92 kWh/tahun, yang setara dengan penghematan sebesar Rp1.931.904,00/tahun dengan nilai investasi sebesar Rp9.005.920,00. Kata kunci: audit energi, tingkat pencahayaan ruang, tingkat pencahayaan kerja, penghematan energi.

Deskripsi Alternatif :

The lighting system at an industrial precision work is related to the safety, accuracy and productivity. The lighting system according to the standard will be able to improve the accuracy and productivity of work. Indonesian Aerospace, Inc is an industry with precision work there in. From the measurements taken, the lighting levels work on Assy Fix Wing Hangar at Indonesian Aerospace, Inc is precision work done amounted to 237,5 lux for Hangar Assy Fix Wing I and 287,2 lux for Assy Fix Wing Hangar II. The value is below standard, that is 300-750 lux (UNEP, 2006). Therefore, it is necessary to audit activities to improve the quality of lighting levels to appropriate with the standard. The method used is the method lumen to determine the level of room lighting and point method to determine the level of work lighting. Alternatives that can be done to improve the quality of existing lighting levels at the lamp, that is the replacement of existing lamp-type LED TSTF 400FL or replacement with high-pressure sodium lamp (HPS), Master SON-T PIA Plus E E40. As for the additional lights, energy saving opportunities available with replacement lamp type LED tube 11.5. Repair and replacement TSTF-400FL can increase light levels up to 347 lux with an investment of Rp1.086.470.000,00. While the type of HPS lamp replacement will only result in illumination of 491 lux and requires an investment of Rp50.948.490,00. Meanwhile, additional lighting replacement to support the work of lighting level with 11.5 type LED tube will provide energy savings of 1609.92 kWh / year, which is equivalent to a saving of Rp1.931.904,00 / year with an investment of Rp9.005.920,00. Keywords: energy audits, level of room lighting, level of work lighting, energy savings.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakErlin Arvelina
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorerlin.arvelina@polban.ac.id
E-mail CKOerlin.arvelina@polban.ac.id

Print ...

Kontributor...

  • Pembimbing: Ir. Conny K. Wachjoe, M.Eng., Ph.D., Editor: Erlin Arvelina

Download...