Pembuatan Alat Pengaturan Laju Aliran Massa Refrigeran Untuk Memenuhi Beban Pendinginan
The Manufacture Of The Measurement Tool Of Refrigerant Mass Flow Rate To Meet Cooling Load
Tugas Akhir, 009 / 2014 / TENUndergraduate Theses from JBPTPPOLBAN / 2018-04-05 12:00:33
Oleh : Marsiska Purnama Sari Safitri - 111711047 (marsiska04@gmail.com)
Dibuat : 2018-04-05, dengan 4 file
Keyword : sistem pendingin, konsumsi energi listrik, inverter, laju aliran massa refrigeran
Subjek : cooling system, electrical energy consumption, inverter, refrigerant mass flow rate
Konsumsi energi listrik terbesar dalam suatu bangunan yaitu digunakan untuk sistem pendingin, dimana sistem pendingin berguna untuk menjaga agar temperatur ruangan tetap dingin sesuai dengan kebutuhan. Namun sistem pendingin yang ada masih banyak menggunakan sistem konvensional dengan sistem dimana sistem pendingin terus bekerja untuk kapasitas yang sama meski pembebanan minimal serta penggunanan sistem on-off pada kompresor apabila beban pendinginan terpenuhi, hal itu tentu tidak menghemat energi. Salah satu penghematan yang dapat dilakukan dengan pengaturan laju aliran massa refrigeran menggunakan inverter yang berkaitan dengan kerja kompresor. Dalam tugas akhir ini dilakukan pembuatan dan pengujian alat pengaturan laju aliran massa refrigeran menggunakan inverter dimana putaran kompresor diatur untuk memenuhi temperatur keluar evaporator yang dibuat konstan sebesar 25⁰C sedangkan temperatur masuk evaporator dibuat bervariasi.. Dari hasil pengujian penggunaan inverter didapat penghematan konsumsi energi listrik sebesar 28,94 % untuk penurunan temperatur sebesar 1⁰C serta penggunaan laju aliran massa refrigeran sebesar 0,0032 kg/s dengan kinerja mesin pendingin (COP) relatif konstan. Kata kunci: sistem pendingin, konsumsi energi listrik, inverter, laju aliran massa refrigeran.
Deskripsi Alternatif :The largest electric energy consumption in a building that is used for the cooling system, cooling system which is useful to keep the room temperature stays cool as needed. However, the existing cooling systems still use a conventional system with a system in which the cooling system continues to work for the same capacity despite the imposition of a minimum as well as common uses on-off system on the compressor when the cooling load is met, it certainly does not save energy. One of the savings that can be done by setting the mass flow rate of refrigerant to use work-related inverter compressor. In this final project performed the manufacture and testing of the tool settings using the mass flow rate of refrigerant compressor inverter where the rotation is set to meet the evaporator exit temperature is kept constant at 25⁰C while the evaporator inlet temperature is varied. From the test results obtained using the inverter saving electrical energy consumption by 28,94% to decrease the temperature by 1⁰C and the use of refrigerant mass flow rate of 0.0032 kg / s with engine cooling performance (COP) is relatively constant. Keywords: cooling system, electrical energy consumption, inverter, refrigerant mass flow rate. Keywords: cooling system, electrical energy consumption, inverter, refrigerant mass flow rate.
Beri Komentar ?#(0) | Bookmark
Properti | Nilai Properti |
---|---|
ID Publisher | JBPTPPOLBAN |
Organisasi | |
Nama Kontak | Erlin Arvelina |
Alamat | Jl. Trsn. Gegerkalong Hilir Ds. Ciwaruga |
Kota | Bandung |
Daerah | Jawa Barat |
Negara | Indonesia |
Telepon | 022 201 3789 ext. 168, 169, 239 |
Fax | 022 201 3889 |
E-mail Administrator | erlin.arvelina@polban.ac.id |
E-mail CKO | erlin.arvelina@polban.ac.id |
Print ...
Kontributor...
- Pembimbing: Bambang Puguh Manunggal, S.T., M.Eng., Editor: Erlin Arvelina
Download...
File : DAFTAR - 111711047.pdf
(658307 bytes)
File : BAB 1 - 111711047.pdf
(170668 bytes)
File : BAB 2 - 111711047.pdf
(673668 bytes)
File : BAB 5 - 111711047.pdf
(162898 bytes)