Path: Top > Tugas Akhir - D3 > Jurusan Teknik Refrigerasi dan Tata Udara > Program Studi Teknik Refrigerasi dan Tata Udara > 2012
Pengaruh Pemasangan Heat Exchanger Tipe Tube in Tube pada Sistem Refrigerasi Dispenser sebagai Upaya Penghematan Energi
The Effect of Installation Tube in Tube Heat Exchanger in Refrigeration System of Dispenser for Saving Energy
Tugas Akhir, 026 / 2012 / RTUUndergraduate Theses from JBPTPPOLBAN / 2014-07-04 09:28:22
Oleh : M. Danny Setiawansyah - 091611044 (dannysetiawansyah@gmail.com)
Dibuat : 2014-07-04, dengan 4 file
Keyword : sistem refrigerasi, alat penukar kalor, penghematan energi
Subjek : vapor compression, heat exchanger, saving energy
Dispenser air minum dengan menggunakan sistem refrigerasi, memiliki daya pemanasan pada heater mencapai 300 W dan daya pendinginan mencapai 130 W. Tanpa disadari daya listrik dari proses pemanasan serta pendinginan air pada dispenser mengkonsumsi daya listrik yang cukup besar. Tujuan dari rancang bangun alat ini dengan memanfaatkan temperatur panas pipa discharge untuk proses pemanasan air sementara sebelum memasuki heater serta membantu kerja heater sehingga heater tidak bekerja terlalu berat dan tidak banyak mengkonsumsi energi listrik. Pemanfaatan panas pipa discharge ini dengan cara membuat alat penukar kalor jenis pipa ganda lawan arah yang memiliki panjang 0,25 m dan berdiameter 25,4 mm yang dibuat sesuai dengan ruang yang tersedia. Diharapkan dengan penambahan alat penukar kalor tersebut akan terjadi penghematan energi. Pengujian dilakukan dengan melakukan pengambilan data tanpa alat penukar kalor serta membandingkanya dengan menggunakan alat penukar kalor. Data penghematan energi akan terlihat pada alat ukur daya yaitu kWh meter. Dari hasil pengujian, dispenser yang menggunakan alat penukar kalor dapat menghemat konsumsi daya listrik sebesar 0,16 kWh per hari atau sebesar 7,6 % per hari. Kata kunci : sistem refrigerasi, alat penukar kalor, penghematan energi
Deskripsi Alternatif :Dispenser with refrigeration system, has a heating power of heater reached 300 W and cooling power reached 130 W. Without realizing in the dispenser , heating and cooling water process consumes considerable the power. The objective of this design with utilizing the discharge heat pipe temperature for heating water process while before it enters the heater and help the heater so the heater doesnt work too hard and dont consume much electricity. The using process from discharge of pipe is making the tube in tube heat exchanger type counter flow which have length 0.25 m and diameter 25.4 mm suitable with the space. Excepted with the addition of heat exchanger, the saving energy will be occur. Testing is done by taking the data without a heat excahnger and compared by using a heat exchanger. The saving energy will be seen in the kWh meter. And the results test, dispenser using a heat exchanger can save electric power consumption of 0,16 kWh per day or 7,6 % per day. Keywords : vapor compression, heat exchanger, saving energy
Beri Komentar ?#(0) | Bookmark
Properti | Nilai Properti |
---|---|
ID Publisher | JBPTPPOLBAN |
Organisasi | |
Nama Kontak | Erlin Arvelina |
Alamat | Jl. Trsn. Gegerkalong Hilir Ds. Ciwaruga |
Kota | Bandung |
Daerah | Jawa Barat |
Negara | Indonesia |
Telepon | 022 201 3789 ext. 168, 169, 239 |
Fax | 022 201 3889 |
E-mail Administrator | erlin.arvelina@polban.ac.id |
E-mail CKO | erlin.arvelina@polban.ac.id |
Print ...
Kontributor...
- Pembimbing 1: Ir. Windy Hermawan Mitrakusuma, MT.
Pembimbing 2: Rudi Rustandi, ST., M.Eng.
, Editor: Erlin Arvelina
Download...
File : DAFTAR - 091611044.pdf
(570746 bytes)
File : BAB 1 - 091611044.pdf
(244969 bytes)
File : BAB 2 - 091611044.pdf
(386799 bytes)
File : BAB 6 - 091611044.pdf
(238146 bytes)