Path: Top > Skripsi - D4 > 2017 > Jurusan Teknik Konversi Energi > Program Studi Teknologi Pembangkit Tenaga Listrik > 2020

Perancangan Pompa Air untuk Sistem Pendingin Tipe Once Through di PLTU Cirebon 660 MW

Design of Water Pump for Once Through Type Cooling System in PLTU Cirebon 660 MW

Skripsi, 029 / 2020 / TPTL
Undergraduate Theses from JBPTPPOLBAN / 2022-04-05 12:49:12
Oleh : M. Fachrul Amarullah Alda - 161724014 (fachrulamarullah@gmail.com)
Dibuat : 2022-04-05, dengan 4 file

Keyword : Air, Kondensor, Pompa, PLTU
Subjek : Pump, Condensor, Steam, Water, PLTU

Laut merupakan sumber air yang sangat melimpah dengan temperatur yang cukup rendah sehingga bisa dimanfaatkan untuk menerapkan sistem sirkulasi air pendingin tipe once through untuk PLTU. Sistem ini memiliki keunggulan yaitu lebih menghemat daya dibandingkan sistem pendingin close cycle karena pada sistem ini tidak diperlukan cooling tower. Untuk menerapkan sistem tersebut, maka dibutuhkan pompa sirkulasi air pendingin tipe vertical wet pit axial flow. Pompa tersebut berfungsi untuk mengalirkan air laut ke kondensor. Agar kondensor dapat bekerja dengan baik maka pompa harus bisa mengalirkan air sebesar 87.995 m3/jam dengan Head sebesar 18 m. Perancangan meliputi water screening intake, intake pompa, dan komponen utama pompa seperti impeller, diffuser, poros, pasak dan casing. Analisa yang dilakukan meliputi analisa performa sistem dan analisa saving cost sehingga dapat dibuktikan bahwa sistem layak digunakan, adanya penghematan daya house load sebesar 9,69 MW dan adanya penghematan biaya penggunaan bahan bakar batu bara hingga 37 Miliar Rupiah per tahun setelah menggunakan sistem pendingin tipe once through. Kata Kunci: Air, Kondensor, Pompa, PLTU.

Deskripsi Alternatif :

The sea is a very abundant source of water with a temperature low enough that it can be used to implement a once through cooling water circulation system for PLTU. This system has the advantage that it saves more power than the close cycle cooling system because this system does not need a cooling tower. To implement this system, a vertical wet pit axial flow cooling water circulation pump is required. The pump functions to drain sea water to the condenser. In order for the condenser to work properly, the pump must be able to flow water of 87,995 m3 / hour with a head of 18 m. The design includes water intake screening, pump intake, and pump main components such as impeller, diffuser, shaft, pin and casing. The analysis includes system performance analysis and cost saving analysis so that it can be proven that the system is feasible to use and that there is a savings of house load power 9,69 MW and applying coal fuel usage costs of up to 37 billion Rupiah per year after using a single type cooling system. Keyword: Pump, Condensor, Steam, Water, PLTU.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakErlin Arvelina
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorerlin.arvelina@polban.ac.id
E-mail CKOerlin.arvelina@polban.ac.id

Print ...

Kontributor...

  • Pembimbing 1: Dr. Ir. Sri Wuryanti, M.Si.

    Pembimbing 2: Slameto, S.T., M.Eng., Editor: Erlin Arvelina

Download...