Path: Top > Tugas Akhir - D3 > 2017 > Jurusan Teknik Sipil > Program Studi Teknik Konstruksi Gedung > 2019
Perencanaan Ulang Pondasi Pada Proyek Gedung No.3 PT Bio Farma Bandung
Redesign Foundation In Number 3 Building Project PT Bio Farma Bandung
Tugas Akhir, 010 / 2019 / KGEUndergraduate Theses from JBPTPPOLBAN / 2020-04-15 21:36:16
Oleh : Mochamad Ilham Sandhia Putra - 161111017 & Vauzan Affandi - 161111030 (vauzanaffandi4@gmail.com)
Dibuat : 2020-04-15, dengan 4 file
Keyword : bored pile, daya dukung, efisiensi, metode pelaksanaan, pile cap
Subjek : bored pile, carrying capacity, efficiency, method of implementation, pile cap
Proyek Pembangunan Gedung No.3 PT.Bio Farma yang dibangun oleh PT.Wika Gedung sebagai kontraktor terletak di Jalan Pasteur No.28 Kota Bandung. Proyek ini memiliki luas lahan sebesar 1,190 m² dengan jumlah 3 lantai. Perencanaan pondasi pada proyek ini menggunakan pondasi bored pile dengan diameter 60 cm dan kedalaman 14 m dengan jenis tanah pasir kerikilan. Perencanaan pondasi pada proyek ini yaitu menghitung beban struktur atas pada aplikasi ETABS untuk mendapatkan reaksi pada kaki-kaki kolom, lalu menghitung daya dukung pondasi berdasarkan asas 2M3S menggunakan data uji lapangan Standard Penetration Test (SPT) dengan menghitung daya dukung pondasi tiang tunggal, efisiensi grup tiang, daya dukung grup tiang, distribusi gaya grup tiang, penurunan tiang elastis, pergeseran kepala tiang, geser pons, daya dukung lateral, gaya tarik, penulangan bored pile dan pile cap. Selain perhitungan, terdapat juga metode pelaksanaan pekerjaan bored pile dan pekerjaan pile cap. Dari hasil perhitungan yang telah dilakukan, didapat 2 tipe pondasi yaitu tipe 2P dan 3P. Grup tiang pada tipe 2P berjumlah 2 buah dan tipe 3P berjumlah 3 buah, dengan menggunakan pondasi bored pile berdiameter 80 cm dan kedalaman 14-15 m, dengan tulangan utama 14D22 dan tulangan sengkang D13-150. Pile cap tipe 2P menggunakan tulangan D19-75 untuk tulangan bawah arah x dan D19-150 untuk tulangan atas arah x, Untuk tulangan bawah arah y menggunakan tulangan D19-75 dan tulangan atas arah y menggunakan tulangan D19-150. Sedangkan pile cap tipe 3P menggunakan tulangan D19-75 untuk tulangan bawah arah x dan D19-150 untuk tulangan atas arah x, Untuk tulangan bawah arah y menggunakan tulangan D19-75 dan tulangan atas arah y menggunakan tulangan D19-150. Kedua tipe pondasi tesebut memenuhi kriteria aman terhadap daya dukung ijin, penurunan elastis, pergeseran kepala tiang, dan geser pons. Kata Kunci: bored pile, daya dukung, efisiensi, metode pelaksanaan, pile cap.
Deskripsi Alternatif :The construction project of PT. Bio Farma building No.3 built by PT. Wika as a contractor is located on Jl. Pasteur No. 28, Bandung. The project has a land area of 1,190 m² with a total of 3 floors. The foundation plan uses a bored pile foundation which has diameter of 60 cm and depth of 14 m with gravel sand soil. The foundation planning of the project is to calculate the upper structural load in the ETABS apps to obtain a reaction on the legs of the column and the bearing capacity of the foundation based on the 2M3S principle using Standard Penetration Test (SPT) field test data by calculating the bearing capacity of a single pile, the efficiency of the pile group, the bearing capacity of the pile group, the distribution of the pile group force, the elastic pile depression, pile head displacement, pons displacement, lateral carrying capacity, tensile force, reinforcement of bored pile and pile cap. In addition, there is also method for carrying out bored pile and pile stamp. From the result of the calculations, the two types of foundations which are 2P and 3P have been found. The total piles in the 2P is two and 3P is three by using bored pile foundation with 80 cm diameter and 14-15 m depth, with main reinforcement 14D22 and stirrup reinforcement D13-150. The pile cap of 2P uses reinforcement D19-75 for the lower reinforcement of x direction and D19-150 for the top reinforcement of x direction. Moreover, the reinforcement D19-75 is used for the lower reinforcement of direction y and D19-150 for the top reinforcement of y direction. On the other hand, the pile cap of 3P uses reinforcement D19-75 for the lower reinforcement of x direction, D19-150 for the top reinforcement of x direction, and D19-75 for lower reinforcement of y direction, and D19-150 for the top reinforcement of y direction. Both types of foundations meet the criteria of permission, elastic depression, pile head displacement and pons displacement. Keywords: bored pile, carrying capacity, efficiency, method of implementation, pile cap.
Beri Komentar ?#(0) | Bookmark
Properti | Nilai Properti |
---|---|
ID Publisher | JBPTPPOLBAN |
Organisasi | |
Nama Kontak | Erlin Arvelina |
Alamat | Jl. Trsn. Gegerkalong Hilir Ds. Ciwaruga |
Kota | Bandung |
Daerah | Jawa Barat |
Negara | Indonesia |
Telepon | 022 201 3789 ext. 168, 169, 239 |
Fax | 022 201 3889 |
E-mail Administrator | erlin.arvelina@polban.ac.id |
E-mail CKO | erlin.arvelina@polban.ac.id |
Print ...
Kontributor...
- Pembimbing 1: Ir. Geni Firuliadhim, M.T.
Pembimbing 2: Dr. Syahril, BSCE., M.T., Editor: Erlin Arvelina
Download...
File : KELENGKAPAN TA - 161111017 & 161111030.pdf
(356365 bytes)
File : BAB 1 - 161111017 & 161111030.pdf
(373363 bytes)
File : BAB 2 - 161111017 & 161111030.pdf
(509668 bytes)
File : BAB 7 - 161111017 & 161111030.pdf
(174732 bytes)