Rancang Bangun Alat Uji Koordinasi MCE dan TOLR dengan Menggunakan Simulator Beban Induktif

Design of MCB and TOLR Coordination Test Equipment with Inductive Load

Tugas Akhir, 027 / 2013 / TLI
Undergraduate Theses from JBPTPPOLBAN / 2017-05-02 10:07:06
Oleh : Mochammad Aldi Lesmana - 101321080 (Youach_dy11@yahoo.com)
Dibuat : 2017-05-02, dengan 4 file

Keyword : simulator, proteksi, beban, TOLR, MCB
Subjek : simulator, protection, load, TOLR, MCB and RL

Motor listrik adalah bagian penting dalam industri sebagai sistem penggerak. Kerusakan pada motor listrik dapat menyebabkan kerugian pada industri karena kegagalan proses produksi. Sistem proteksi pada motor listrik diperlukan untuk menjaga keandalan sistem yaitu koordinasi antara MCB dan TOLR. Proyek akhir ini ditujukan untuk membuat simulator alat uji koordinasi MCB dan TOLR menggunakan beban induktif. Perancangan dilakukan dengan menentukan kriteria kerja alat diantaranya tegangan kerja 220V, frequensi 50Hz, terdapat lampu indikator untuk mengetahui komponen proteksi yang bekerja dan spesifikasi komponen. Dari hasil pengujian didapat bahwa MCB berfungsi sebagai pengamanan hubung singkat sedangkan TOLR sebagai pengaman beban lebih. Agar mendapat sistem proteksi yang baik, digunakan setting proteksi yang sesuai. Kata kunci: simulator, proteksi, beban, TOLR, MCB.

Deskripsi Alternatif :

Electric motors are important tools of the propulsion systems industry. The fault of the electric motor can cause sigificant losses to the industry. One of necessary protection of electric motor to maintain the system reliability is the coordination between MCB and TOLR. This final project is intended to create a simulator test of protection coordination of TOLR and MCB using inductive loads. Design is done by specifying criteria of the operating rate, such as working voltage 220V, frequency 50Hz. There are indicator lights to identify what protective devices are operated. The results of simulator test show that MCB serves as short circuit protection whereas TOLR as overload protection. In order to obtain a good protection system, the graphics show the appropriate protection settings is very important. Keywords: simulator, protection, load, TOLR, MCB and RL.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakErlin Arvelina
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorerlin.arvelina@polban.ac.id
E-mail CKOerlin.arvelina@polban.ac.id

Print ...

Kontributor...

  • Pembimbing 1: Toto Tohir, ST., M.T.

    Pembimbing 2: Nanang Mulyono, S.T., M.T., Editor: Erlin Arvelina

Download...