Mesin frais adalah salah satu fasilitas yang digunakan untuk menunjang praktek pada proses pemesinan namun seiring berjalannya waktu dan seringnya digunakan untuk penunjang / pendukung pembuatan alat atau persiapan bahan praktek mahasiswa maka kondisi dari mesin frais ini semakin menurun. Penurunan ini ditandai dengan bagian gib-strip (baji) yang berposisi dibagian eretan meja mengalami karat dan longgar sehingga menyebabkan kinerja mesin kurang maksimal, seperti kedudukan meja miring ketika di oprasikan, getaran pada meja berlebih dan beberapa spesimen yang dikerjakan terdapat ukuran yang keluar dari toleransi. Rekondisi ini dilakukan pada Mesin Frais Aciera type F4 yang berada di Laboratorium Fabrikasi Teknik Mesin Politeknik Negeri Bandung (POLBAN). Proses rekondisi mesin frais ini di titik beratkan pada bagian eretan mesin frais. Setelah dilakukan rekondisi mesin frais ini dapat dilihat pada hasil uji fungsi menunjukan benda kerja yang dihasilkan memiliki ketebalan sebesar 38 mm pada kedua sisi permukaan sehingga tidak terdapat selisih dan kekasaran permukaan benda kerja yang telah diproses oleh mesin tersebut didapat Ra 0.18/N7 dalam tabel Normen auszug dengan kedalaman permukaan sebesar 3mm dengan Vc 25 m/menit dan dengan hasil uji geometris kedataran meja mengunakan alat ukur spirit level sebesar 0,07mm. Kata Kunci: Uji Geometris, Kedataran, Kekasaran.
Deskripsi Alternatif :Frais machine is one of facilities that used to support the practice in the machining process but as time as goes by, and often used for colleger practice then the condition of the frais machine it self decreases. The decline is marked by the gib-strip which is positioned on the sled is worn and loos so that causing machine performance not maximal, as the position of the tilt table when operated, excessive vibration on the table a few specimens that worked there is measure that coming out of tolerances. This reconditioning was performanced on aciera frais machine type F4 which is in the fabrication laboratory Mechanical Engineering Politeknik Negeri Bandung (POLBAN). The reconditioning process of frais machine is focused on the sledge frais machine after reconditioned this frais machine can be seen on the function test result shows that the workpiece has a thickness of 38 mm on both sides of the workpiece so there is no difference and his rudeness the surface of the workpiece which has been processed by that machine obtained Ra 0,18/N7 in the "Normen Auszug" table with a depth of the surface of 3 mm with Vc 25m/minute and with the geometrical test result level of table used a measure spirit level of 0.07 mm. Keywords: Geometrical Test, leveling, Rudenes.
Beri Komentar ?#(0) | Bookmark
Properti | Nilai Properti |
---|---|
ID Publisher | JBPTPPOLBAN |
Organisasi | |
Nama Kontak | Erlin Arvelina |
Alamat | Jl. Trsn. Gegerkalong Hilir Ds. Ciwaruga |
Kota | Bandung |
Daerah | Jawa Barat |
Negara | Indonesia |
Telepon | 022 201 3789 ext. 168, 169, 239 |
Fax | 022 201 3889 |
E-mail Administrator | erlin.arvelina@polban.ac.id |
E-mail CKO | erlin.arvelina@polban.ac.id |
Print ...
Kontributor...
- Pembimbing 1: Rodian Situmorang, B.S.M.E.T., M.Eng.
Pembimbing 2: Deni Mulyana, S.T., M.T., Editor: Erlin Arvelina
Download...
File : KELENGKAPAN TA - 141211020.pdf
(804959 bytes)
File : BAB 1 - 141211020.pdf
(215069 bytes)
File : BAB 2 - 141211020.pdf
(1013471 bytes)
File : BAB 5 - 141211020.pdf
(167264 bytes)