Path: Top > Tugas Akhir - D3 > 2017 > Jurusan Teknik Mesin > Program Studi Teknik Mesin > 2018
Analisis Kebisingan Pada Turbin Francis Terhadap Kesehatan Dan Keselamatan Kerja Di Power House PT Indonesia Power, Sub Unit PLTA Bengkok
Noise Analysis of Francis Turbine for Health, Safety, and Environment at Power House PT Indonesia Power, Sub Unit PLTA Bengkok
Tugas Akhir, 017 / 2018 / TMEUndergraduate Theses from JBPTPPOLBAN / 2019-01-22 10:25:01
Oleh : Muhammad Al Izza - 151211018 (muhammadalizza1@gmail.com)
Dibuat : 2019-01-22, dengan 4 file
Keyword : Turbin air, Kebisingan, Sound Level Meter, Metode Grid
Subjek : Hydro Turbine, Noise, Sound Level Meter, Grid Method
Turbin air merupakan salah satu jenis peralatan yang banyak digunakan di industri pembangkit listrik. Turbin air memiliki peranan penting dalam mengubah energi kinetik pada air menjadi energi mekanik berupa putaran turbin untuk memutarkan generator dalam menghasilkan listrik. Sebagai sebuah rotating equipment, turbin air tentu menghasilkan kebisingan ketika beroperasi. Kebisingan yang dihasilkan dapat berupa kebisingan kontinyu, impulsif, atau terputus-putus tergantung dari kondisi turbin air itu sendiri. Dalam pengoperasinnya, kebisingan yang dihasilkan oleh turbin air dapat berakibat pada terganggunya kondisi fisik dan psikologis operator turbin air apabila waktu pemaparan kebisingan tidak sesuai dengan standar yang telah ditentukan. Maka dari itu, perlu adanya inspeksi kebisingan untuk mengetahui tingkat kebisingan beserta pola sebaran kebisingan di dalam power house. Alat ukur yang digunakan dalam pengukuran kebisingan yaitu Sound Level Meter. Pengukuran dilakukan di beberapa titik pada turbin air menggunakan metode grid. Metode analisis kebisingan yang digunakan yaitu analisis besar intensitas kebisingan (dB), comparative, dan descriptive. Objek yang diamati yaitu turbin air di PT. Indonesia Power , Sub Unit Bengkok. Hasil yang didapatkan yaitu pada ruang turbin baik kondisi 1, 2, maupun 3 rata-rata nilai kebisingan yang terukur yaitu 93,5 dB, 91,3 dB, dan 90,8 dB , sedangkan pada ruang penyimpanan dan ruang operator saat kondisi 1, 2, dan 3 seluruhnya tidak melebihi ambang batas aman 85 dB(A). Selain itu, durasi aman paparan kebisingan yaitu pada ruang turbin 1 jam, pada ruang penyimpanan > 8 jam, dan pada ruang operator >8 jam. Kemudian, alat pelindung pendengaran yang disarankan yaitu earmuff. Kata kunci: Turbin air, Kebisingan, Sound Level Meter, Metode Grid.
Deskripsi Alternatif :Hydro Turbine is one of a kind equipment that used by many power house industries. Hydro Turbine has an important role in changing kinetic energy from water flow into mechanical energy such as turbine rotation to rotate the generator for making electricity. As a rotating equipment, hydro turbine can produce noise when it operated. A kind of noise which hydro turbine produce can be categorized as continuous, impulsive, or discontinuous noise, it depends on the turbine condition itself. In operation, noise generated by hydro turbine can lead to disruption of operator physical and psychological healthiness, if the exposure time doesn't appropriate with the standard which has been determined. Therefore, noise inspection is needed to find out the level of noise and it spreading pattern inside the power house. Measuring instrument which used in noise measurement is Sound Level Meter. Measurements made in several points around the turbine using grid method. Method of analysis are analysis amount of noise level (dB), comparative, and descriptive. The object for this analysis is hydro turbine in PT. Indonesia Power, Sub Unit Bengkok. As the result, average noise number that had been measured in turbine room either in condition 1,2, or 3 are 93,5 dB, 91,3 dB, and 90,8 dB, whereas in storage room and operator room either in condition 1, 2, or 3 not over the 85 dB safe threshold. Other than that, safe exposure time for noise in turbine room are 1 hour, in storage room are >8 hour, and in operator room are >8 hour. Then, the recommendation for hearing protective devices is earmuff. Keywords: Hydro Turbine, Noise, Sound Level Meter, Grid Method.
Beri Komentar ?#(0) | Bookmark
Properti | Nilai Properti |
---|---|
ID Publisher | JBPTPPOLBAN |
Organisasi | |
Nama Kontak | Erlin Arvelina |
Alamat | Jl. Trsn. Gegerkalong Hilir Ds. Ciwaruga |
Kota | Bandung |
Daerah | Jawa Barat |
Negara | Indonesia |
Telepon | 022 201 3789 ext. 168, 169, 239 |
Fax | 022 201 3889 |
E-mail Administrator | erlin.arvelina@polban.ac.id |
E-mail CKO | erlin.arvelina@polban.ac.id |
Print ...
Kontributor...
- Pembimbing 1: Ir. Mokhamad Munir Fahmi, M.T.
Pembimbing 2: Drs. Abdul Karim, M.Eng., Editor: Erlin Arvelina
Download...
File : KELENGKAPAN TA - 151211018.pdf
(618706 bytes)
File : BAB 1 - 151211018.pdf
(134331 bytes)
File : BAB 2 - 151211018.pdf
(700620 bytes)
File : BAB 5 - 151211018.pdf
(87688 bytes)