Desain Buck-Boost Konverter Untuk Meningkatkan Ekstraksi Daya Pada Panel Surya Dengan Metode Perturb & Observe

Buck-Boost Converter Design To Enhance Power Extraction On Solar Panel With Perturb & Observe Method

Skripsi, 020 / 2018 / EK
Undergraduate Theses from JBPTPPOLBAN / 2018-11-08 14:40:24
Oleh : Muhammad Fahmy Dzakwan - 141354022 (mfahmydzakwan@gmail.com)
Dibuat : 2018-11-08, dengan 4 file

Keyword : panel surya, MPPT, Perturb & Observe, Buck-Boost Converter
Subjek : solar panel, MPPT, Perturb & Observe, Buck-Boost Converter

Salah satu masalah yang terjadi pada panel surya adalah rendahnya nilai ekstraksi daya panel surya saat dihubungkan langsung ke beban tanpa menggunakan charge controller. Hal tersebut menyebabkan daya yang tersampaikan ke beban lebih rendah dari daya yang dikeluarkan oleh panel surya. Tugas akhir ini membuat sistem elektronik yang dapat mengoptimalisasi pengekstrakan daya panel surya berbasis dc-dc converter tipe Buck-Boost Converter non-inverting. Metode yang digunakan untuk mengoptimalisasikan ekstraksi daya adalah MPPT Perturb & Observe. Hasil uji alat menunjukan sebelum menggunakan MPPT P&O nilai rata-rata persentase ekstraksi dayanya adalah 62.64%. Setelah menggunakan MPPT P&O nilai rata-rata persentase ekstraksi dayanya menjadi 84.35% untuk mode Buck dan 88.99% untuk mode Boost. Jadi, MPPT berhasil meningkatkan nilai rata-rata persentase ekstraksi daya sebesar 21.71% dari persentase ekstraksi daya tanpa MPPT untuk mode Buck dan meningkatkan rata-rata persentase ekstraksi daya sebesar 26.35% dari persentase ekstraksi daya tanpa MPPT pada mode Boost. Kata kunci: panel surya, MPPT, Perturb & Observe, Buck-Boost Converter.

Deskripsi Alternatif :

One of the problems that occur in solar panels is the low value of solar panel power extraction when connected directly to the load without using a charge controller. This causes the power delivered to the load to be lower than the power released by the solar panel. This final project makes an electronic system that can optimize the extraction of solar panel power based on the DC-DC converter type Buck-Boost Converter non-inverting. The method used to optimize power extraction is MPPT Perturb & Observe. The results of the tool test showed that before using MPPT P & O the average value of the extraction percentage was 62.64%. After using MPPT P & O the average value of the extraction percentage is 84.35% for Buck mode and 88.99% for Boost mode. So, MPPT succeeded in increasing the average value of power extraction percentage by 21.71% from the power extraction percentage without MPPT for Buck mode and increasing the average power extraction percentage by 26.35% from the power extraction percentage without MPPT in Boost mode. Keywords: solar panel, MPPT, Perturb & Observe, Buck-Boost Converter.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakErlin Arvelina
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorerlin.arvelina@polban.ac.id
E-mail CKOerlin.arvelina@polban.ac.id

Print ...

Kontributor...

  • Pembimbing 1: Sabar Pramono, BSEE., M.T.

    Pembimbing 2: Dr. Dra. Peni Handayani, S.T., M.T., Editor: Erlin Arvelina

Download...