Rancangan Hot Well Pump Untuk PLTP Flash Steam Kapasitas 55 MW

The Design of Hot Well Pump for Flash Steam Geothermal Power Plant with 55 MW Capacity

Tugas Akhir, 018 / 2017 / TPTL
Undergraduate Theses from JBPTPPOLBAN / 2018-09-03 15:05:20
Oleh : Muhammad Hanifa - 131724022 (muhammadhanifaa2@gmail.com)
Dibuat : 2017-12-07, dengan 4 file

Keyword : PLTP, sistem sirkulasi utama kondensat, impeler aliran campuran, karakteristik pompa
Subjek : Geothermal Power Plant, main circulating condensate system, mixed flow impeller, characteristic of pump

Pada sistem Pembangkit Listrik Tenaga Panas Bumi, uap yang digunakan untuk memutar turbin berasal dari perut bumi, uap yang telah digunakan untuk memutar turbin lalu dikondensasikan di dalam kondensor. Tugas Akhir ini berisi tentang sistem pendinginan kondensat dengan cara menyalurkan kondensat yang sudah dikondensasi menuju menara pendingin oleh pompa pada Pembangkit Listrik Tenaga Panas Bumi. Jenis pompa yang sering digunakan adalah pompa aliran campuran karena dapat menyalurkan kondensat dengan kapasitas dan head yang cukup tinggi. Perancangan pompa diawali dengan menentukan parameter awal seperti tekanan, laju alir serta temperatur fluida pada sisi masuk dan keluar pompa menggunakan Cycle Tempo 5.0 untuk Pembangkit Listrik Tenaga Panas Bumi kapasitas 55 MW. Laju alir volume kondensat pada pompa yaitu 1,52 m3/s. Langkah selanjutnya yaitu dengan menghitung head total lalu didapatkan nilainya sebesar 46,77 meter serta menghitung NPSH yang tersedia dan NPSH yang diperlukan di mana nilai NPSH yang tersedia nilanya harus lebih besar dari NPSH yang diperlukan. Dari hasil perancangan didapat diameter impeler pompa pada sisi masuk sebesar 0,506 meter dan sisi keluar 0,856 meter dengan lebar sisi masuk impeler 0,162 meter dan sisi keluar 0,114 meter lalu jumlah sudu adalah 10 buah. Pompa bekerja pada putaran 750 rpm dan daya pompa sebesar 785 kW pada efisiensi 88%. Karakteristik operasi pompa didapat dari pendekatan matematis dengan hasil, head¬ nilainya berbanding terbalik dengan kapasitas pompa, daya pompa sebanding dengan kapasitas lalu efisiensi tertinggi dari daya penggerak berbading dengan daya hidrolis sebesar 71%. Kata Kunci: PLTP, sistem sirkulasi utama kondensat, impeler aliran campuran, karakteristik pompa.

Deskripsi Alternatif :

In a Geothermal Power Plant system, steam that is used to rotate the turbine comes from inside the earth. The steam that has been used to rotate the turbine will then be condensed in the condenser. This final project contains about the technique that frequently used to cool down the condensate in condensate cooling system is by channelling it to cooling towers by pumps in Geothermal Power Plant. The type of pump that is suitable for this system is mixed flow pump as it can deliver condensate at high capacity and head. The design of the pump begins with determining the initial parameters such as pressure, flow rate and fluid temperature at the inlet and outlet side of the pump using Cycle Tempo 5.0 for Geothermal Power Plant with 55 MW capacity. The volumetric flow rate of the condensate at the pump is 1.52 m3/s. The next step is to calculate the total head with obtained value of 46.77 meters and calculate the available NPSH and required NPSH where the value of the available NPSH should be greater than required NPSH. From the design, the diameters of the inlet and the outlet side of the pump impeller are 0.506 meter and 0.856 meters respectively. The widths at the inlet and the outlet sides of the impeller are 0.162 meters and 0.114 meters respectively with the number of blades of 10. The pump operates at 750 rpm and pumping power of 785 kW at 88% efficiency. The characteristics of the pump that are obtained from mathematical approach shows that the value of the head is inversely proportional with the pump capacity, the pump power is proportional with its capacity, and the peak efficiency as the ratio between driver power and the hydraulic power is 71%. Keywords: Geothermal Power Plant, main circulating condensate system, mixed flow impeller, characteristic of pump.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakErlin Arvelina
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorerlin.arvelina@polban.ac.id
E-mail CKOerlin.arvelina@polban.ac.id

Print ...

Kontributor...

  • Pembimbing 1: Drs. Maridjo, M.T.


    Pembimbing 2: Dr. Ir. Sri Wuryanti, M.Si., Editor: Erlin Arvelina

Download...