Perancagan Heat Exchanger Shell and Tube Tipe Helical Baffle di Water Treatment Plant PT Sanbe Farma

Shell and Tube Heat Exchanger Design Type Helical Baffle at Water Treatment Plant PT Sanbe Farma

Skripsi, 016 / 2021 / TKE
Undergraduate Theses from JBPTPPOLBAN / 2022-12-28 13:23:22
Oleh : Muhammad Idham Nugroho - 171734019 (muhammad.idham.tken417@polban.ac.id)
Dibuat : 2022-12-28, dengan 4 file

Keyword : Heat Exchanger, Helical Baffle, Pressure Drop, Penghematan
Subjek : Heat Exchanger, Helical Baffle, Pressure Drop, Saving

Heat Exchanger merupakan alat yang berfungsi untuk mentransfer energi panas anatara dua atau lebih fluida. Pada PT Sanbe Farma terdapat heat exchanger yang berfungsi sebagai pendingin WFI (Water For Injection). Air injeksi dari WFI digunakan untuk bahan baku obat. Heat Exchanger pada WFI merupakan shell and tube heat exchanger dengan segmental baffle. Fluida yang mengalir pada sisi shell merupakan air injeksi sementara fluida pada sisi tube merupakan air. Heat exchanger memiliki beberapa komponen, salah satunya adalah baffel. Baffle merupakan sekat yang berfungsi untuk mengatur aliran yang melewati sisi shell dan meningkatkan turbulensi menjadi lebih tinggi. Selain baffle type segmental, terdapat baffle type helical. Helical baffle memiliki keuntungan yaitu dapat mengurangi nilai pressure drop serta mengurangi masalah fouling factor. Tugas Akhir ini menggunakan metode kuantitatif dengan data primer bersumber dari industri yang terkait serta data sekunder bersumber dari jurnal dan textbook. Data dianalisa berdasarkan hasil penghitungan manual berdasarkan persamaan pada Process Heat Transfer (D.Q Kern,1965) dan validasi dengan perangkat lunak Heat Transfer Research Inc (HTRI). Perancangan helical baffle menggunakan variasi sudut kemiringan 3o, 6o, 9o, 12o, 15o, 18, 21o, 24o. Helical baffle yang dirancang harus memenuhi syarat perancangan yaitu pressure drop ≤ 10 psi dan fouling factor penghitungan ≥ fouling factor ketentuan. Sudut kemiringan helical baffle yang memenuhi syarat perancangan adalah sudut 3o. Perancangan helical baffle dengan sudut kemiringan 3o dapat menurunkan pressure drop ari injeksi di sisi shell dari 48,86 Psi menjadi 9,07 Psi. Fouling factor yang didapat dari hasil perancangan ini sebesar 0,00922 m2 oC/W (lebih besar 6% dari fouling factor ketentuan). Efektivitas dari heat exchanger shell and tube mengalami peningkatan dari 0,52 menjadi 0,61. Peluang pengehematan energi dari perancangan ini mencapai Rp. 518.063.162,53 per tahun. Kata kunci: Heat Exchanger, Helical Baffle, Pressure Drop, Penghematan.

Deskripsi Alternatif :

Heat Exchanger is a device that serves to transfer heat energy between two or more fluids. At PT Sanbe Farma there is a heat exchanger that functions as a WFI (Water For Injection) cooler. Water injection from WFI is used as raw material for medicine. The heat exchanger in WFI is a shell and tube heat exchanger with segmental baffles. The fluid flowing on the shell side is injection water while the fluid on the tube side is water. The heat exchanger has several components, one of which is the baffel. Baffle is a bulkhead that serves to regulate the flow through the shell side and increase turbulence to be higher. In addition to the segmental type baffle, there is a helical type baffle. The helical baffle has the advantage that it can reduce the value of the pressure drop and reduce the problem of the fouling factor. This Final Project uses quantitative methods with primary data sourced from the related industry and secondary data sourced from journals and textbooks. Data were analyzed based on the results of manual calculations based on equations in Process Heat Transfer (D.Q Kern, 1965) and validation with Heat Transfer Research Inc (HTRI) software. The design of the helical baffle uses variations in the angle of 3o, 6o, 9o, 12o, 15o, 18, 21o, 24o. The designed helical baffle must meet the design requirements, namely pressure drop 10 psi and fouling factor calculation fouling factor provisions. The helical baffle tilt angle that meets the design requirements is 3o. The helical baffle design with a tilt angle of 3o can reduce the pressure drop from injection on the shell side from 48.86 Psi to 9.07 Psi. The fouling factor obtained from the results of this design is 0.00922 m2 oC/W (6% greater than the specified fouling factor). The effectiveness of the shell and tube heat exchanger increased from 0.52 to 0.61. The energy saving opportunity from this design reaches Rp. 518,063,162.53 per year. Keywords: Heat Exchanger, Helical Baffle, Pressure Drop, Saving.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakErlin Arvelina
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorerlin.arvelina@polban.ac.id
E-mail CKOerlin.arvelina@polban.ac.id

Print ...

Kontributor...

  • Pembimbing 1: Dr. Dra. Sri Widarti, M.Si., M.Sc.

    Pembimbing 2: Dr. Ir. Sri Wuryanti, M.Si., Editor: Erlin Arvelina

Download...