Rekondisi Sistem Mekanik Alat Uji Simulasi Turbin Kaplan

Reconditioning of Mechanical System of Kaplan Turbine Simulation Test Equipment

Tugas Akhir, 019 / 2018 / TME
Undergraduate Theses from JBPTPPOLBAN / 2019-01-22 10:31:45
Oleh : Muhammad Luthfan Zharif Aqil - 151211020 (muhammad.luthfan.tme15@polban.ac.id)
Dibuat : 2019-01-22, dengan 4 file

Keyword : Alat Uji Simulasi Turbin Air Kaplan, Pompa Sentrifugal, Rekondisi, Kinerja
Subjek : Kaplan Turbine Simulation Test Equipment, Centrifugal Pump, Reconditioning, Performance

Alat uji simulasi turbin tipe Kaplan di Laboratorium Fluida, Termal, dan Otomotif Jurusan Teknik Mesin Politeknik Negeri Bandung digunakan sebagai media praktikum mahasiswa jurusan teknik mesin untuk mengetahui prinsip kerja dan karakteristik kinerja dari sistem turbin Kaplan. Pada alat uji simulasi turbin kaplan tersebut digunakan pompa sentrifugal dengan daya motor 7,5 KW yang berfungsi untuk mensirkulasikan air ke turbin kaplan. Pemakaian yang relatif lama sebagai alat pratikum membuat alat uji simulasi turbin air kaplan saat ini memiliki berbagai macam masalah pada sistem kerjanya. Permasalahan banyak timbul pada sistem kerja mekanik dari alat uji simulasi turbin air kaplan itu seperti kebocoran pada sistem pompa, kondisi alat instrument yang kurang baik, misalignment antara kopling turbin kaplan dan generator, dan terjadi getaran yang tinggi pada bagian turbin. Oleh karena itu, perlu adanya rekondisi terutama pada sistem mekanik untuk mengatasi permasalahan tersebut. Langkah-langkah yang dilakukan diantaranya dengan melakukan pengecekan awal pada kebocoran yang ada di sistem alat uji simulasi turbin air kaplan ketika beroperasi kemudian dilanjutkan dengan dilakukannya overhaul pada pompa untuk melakukan perbaikan sesuai dengan indikasi kebocoran dan getaran yang terjadi, lalu selanjutkan akan dilakukan pengecekan terhadap alat instrument untuk memastikan alat dalam kondisi baik, dan terakhir akan dilakukan alignment pada akhir kegiatan rekondisi. Setelah dilakukannya rekondisi, hasil perhitungan menunjukan bahwa efisiensi total tertinggi terjadi pada putaran pompa 900 rpm (30 Hz) dengan bukaan katup 30˚ yaitu sebesar 41 %, sedangkan untuk efisiensi total terendah terjadi pada putaran pompa 1050 rpm (35 Hz) dengan bukaan katup 90˚ yaitu sebesar 30%. Dari hasil ini maka terjadi peningkatan efisiensi total sistem setelah dilakukannya rekondisi dari 28-30 % meningkat sampai 28-41 %. Kata Kunci: Alat Uji Simulasi Turbin Air Kaplan, Pompa Sentrifugal, Rekondisi, Kinerja.

Deskripsi Alternatif :

Kaplan turbine simulation test equipment at the Fluid, Thermal, and Automotive Laboratory Department of Mechanical Engineering at Bandung State Polytechnic is used as a practice for students majoring in mechanical engineering to know the working principle and performance characteristics of Kaplan turbine system. Centrifugal pump with 7,5 KW motor power is used in Kaplan turbine simulation test equipment to serve circulating water to Kaplan turbine. The relatively long use as a praticum makes the Kaplan turbine test equipment simulation currently has a problems in the working system. Many problems arises in the mechanical work system of the Kaplan turbine simulation test equipment such as leakage on the pump system, bad instrument condition, misalignment between the clutch of turbine and generator turbine, and high vibration on the turbine. Therefore, reconditioning is needed especially on mechanical systems to resolve these problems. Step to reconditioning is checking on the leaks that exist in the system of kaplan turbine simulation test equipment when it is operated and then continue to overhaul the pump as a repairment in accordance to indication of leakage and vibration that occurs, then check the instrument to ensure the equipment is in good condition, and the last is alignment to end the reconditioning activity. After reconditioning, the calculation results show that the highest overall efficiency at 900 rpm pump rotation with 30˚ valve openings are 41%, while for the lowest overall efficiency at 1050 rpm pump rotation with valve 90 openings are 30%. From these results there is an increase in total system efficiency after reconditioning from 28 - 30% increases to 28-41%. Keywords: Kaplan Turbine Simulation Test Equipment, Centrifugal Pump, Reconditioning, Performance

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakErlin Arvelina
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorerlin.arvelina@polban.ac.id
E-mail CKOerlin.arvelina@polban.ac.id

Print ...

Kontributor...

  • Pembimbing 1: Ir. Ali Mahmudi, M.Eng.

    Pembimbing 2: Rudy Yuni Widiatmoko, B.Eng., M.Sc., Editor: Erlin Arvelina

Download...