Path: Top > Skripsi - D4 > 2017 > Jurusan Teknik Konversi Energi > Program Studi Teknologi Pembangkit Tenaga Listrik > 2017

Rancangan Sistem Proteksi Generator Dengan Kapasitas 800 MVA Untuk Sistem PLTU

The Design of 720 MW Generator Protection System for PLTU System

Tugas Akhir, 015 / 2017 / TPTL
Undergraduate Theses from JBPTPPOLBAN / 2018-09-03 15:05:20
Oleh : Muhammad Rifkie Fitriady - 121724019 (fitriady.48@gmail.com)
Dibuat : 2017-12-07, dengan 4 file

Keyword : relay, seting relay, daya balik, relay diferensial
Subjek : relay, setting relay, differential relay

Pada sistem Pembangkit Listrik Tenaga Uap (PLTU) terdapat beberapa komponen, baik dalam aspek kelistrikan maupun aspek mekanik. Salah satu komponen utama pada system PLTU adalah generator yang berfungsi sebagai pembangkit tenaga listrik yang kemudian disuplaikan ke jaringan. Dikarenakan pentingnya fungsi generator tersebut, tentu perlu didukung oleh sistem proteksi yang handal sehingga generator akan tetap terjaga keselamatannya dari berbagai macam gangguan. Pada laporan ini sistem proteksi yang dibahas meliputi sistem proteksi dalam aspek kelistrikan. Sistem proteksi yang handal ditentukan berdasarkan penentuan pemutus tenaga, transformator arus, dan setting relay. Setting relay tersebut ditentukan berdasarkan standar, perhitungan hubung singkat, dan pertimbangan damage curve alat yang diproteksi. Berdasarkan hasil rancangan didapatkan bahwa relay yang digunakan berupa relay arus hubung singkat, 2,53 Ampere, Relay arus beban lebih dengan seting 1,45 Ampere, relay diferensial dengan slope atau bias diferensial sebesar 18 % dan relay daya balik dengan setting 2% dari rating daya aktifnya. Untuk memverivikasi kesesuaian antara perhitungan dan kondisi pada saat terjadi gangguan, digunakan software Electrical Transient Analysis Program (ETAP) dan hasilnya menunjukkan bahwa hasil rancangan proteksi mampu mengamankan gangguan yang kemungkinan terjadi pada generator baik yang bersifat internal maupun eksternal. Kata kunci: relay, seting relay, daya balik, relay diferensial.

Deskripsi Alternatif :

In the Steam Power Plant system there are several components, both in electrical aspect and mechanical aspect. One of the main components of the PLTU system is a generator that have functions to produce electrical energy which then supplied to the network. Due to importance function of generator, of course it need to be supported by a reliable protection system. So that the generator will be kept safe from various kinds of interference. Protection system that discusses in this report is generator protection system in electrical aspect. A reliable protection system has to consider the capability of circuit breaker, current transformer, and relay setting. Relay setting was determined by guidance of electrical standard, short circuit calculations, and consideration of damage curve. a Based on the results, Relay setting for Overcurrent relay is, 2,53 Ampere, setting for Overload relay is 1,45 Ampere, slope setting for differential relay is 19.22 %, and setting for power reverse relay is 2% from active power.. To verify calculation of relay setting, a program named Electrical Transient Analysis (ETAP) is used. Keywords: relay, setting relay, differential relay.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakErlin Arvelina
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorerlin.arvelina@polban.ac.id
E-mail CKOerlin.arvelina@polban.ac.id

Print ...

Kontributor...

  • Pembimbing: Drs. Ali Mashar, M.Eng.Sc., Editor: Erlin Arvelina

Download...