Subjek : cyclone separator, efficiency, steam

Pembangkit Listrik Tenaga Panas Bumi memanfaatkan steam yang berasal dari perut bumi. Steam tersebut banyak mengandung material lain yang dapat merusak kerja unit, maka dipasang separator siklon untuk membersihkan steam dari material padat lain. Kerja yang dilakukan separator siklon diharapkan memiliki nilai efisiensi yang tinggi agar dapat menghindari kerusakan pada komponen unit lainnya, maka dari itu perlu adanya pengujian kerja dari separator siklon yang digunakan di PLTP Indonesia Power untuk mengetahui apakah kerja separator siklon sudah dapat dikatan efisien atau tidak. Tugas akhir ini berjudul “Uji Performansi Separator siklon Siklon Di PLTP Indonesia Power UBP Kamojang Unit Darajat”. Pada tugas akhir ini dibahas mengenai cara kerja separator siklon dan perhitungan efisiensi separator siklon sehingga dapat diketahui kualitas uap yang digunakan pada sistem. Tujuan tugas akhir ini adalah mengetahui nilai efisiensi separator siklon yang digunakan. Metode penulisan yang dilakukan yaitu dengan cara metode survey, observasi dan wawancara. Hasil dari tugas akhir ini adalah mengetahui nilai efisiensi kerja separator siklon yang telah dihitung yaitu sebesar 6% sehingga dapat diketahui kelayakan separator siklon dan uap yang digunakan. Kata kunci: separator siklon, efisiensi, steam.

Deskripsi Alternatif :

Geothermal power plants utilize steam coming from inside the earth. The steam contains a lot of others materials that can damage the unit work. Then Separator cyclone was installed for steam cleaning of others solid material. Work performance of cyclone separator was expected to have high work efficiency in order to avoid damage to the components of other units. Thus the need for testing the work of cyclone separator used in Indonesian geothermal power to determine whether the work can be said cyclone separator is efficient or inefficient. This final project entitled "Uji Performansi Separator Siklon di PLTP Indonesia Power UBP Kamojang Unit Darajat". In this final project discussed about the workings of cyclone separator and calculation efficiency separator cyclone so that can be known the quality of the steam used in the system. The aim of this final project was to determine the efficiency of the separator cyclone. The method is carried out is by method of survey, observation and interview. The results of this final project was to determine the value of work efficiency cyclone separator which has been calculated in the amount of 6% in order to know the feasibility of cyclone separator and steam are used. Keywords: cyclone separator, efficiency, steam.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakErlin Arvelina
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorerlin.arvelina@polban.ac.id
E-mail CKOerlin.arvelina@polban.ac.id

Print ...

Kontributor...

  • Pembimbing 1: Ir. Sugiyarto, M.T.

    Pembimbing 2: Luga Martin Simbolon, S.T., M.Sc., Editor: Erlin Arvelina

Download...