Pembuatan Alat Penukar Kalor Tipe Wound Serpentine Pada Split Air Conditioning Water Heater (S-ACWH)

Manufacture Of Heat Exchanger Type Wound Serpentine On Split Air Conditioning Water Heater (S-ACWH)

Tugas Akhir, 057 / 2014 / TEN
Undergraduate Theses from JBPTPPOLBAN / 2018-04-20 10:29:59
Oleh : Nandang Susanto - 111711017 (hanacaraka.sunda.1@gmail.com)
Dibuat : 2018-04-20, dengan 4 file

Keyword : S-ACWH, Natural Convection, Wound Serpentine, Pemanas Air,Tangki Air
Subjek : S-ACWH, Natural Convection, Wound Serpentine, Water Heaters, Water Tank

Split Air Conditioning Water Heater (S-ACWH) merupakan salah satu sistem pemanas air yang hemat energi karena hanya memanfaatkan panas buang dari Air Conditioner. Alat penukar kalor tipe wound serpentine merupakan tipe yang paling baik digunakan pada sistem S-ACWH karena menggunakan prinsip natural convection dimana pipa wound serpentine diletakkan di dasar tangki air sehingga kalor dapat berpindah dari dasar tangki menuju ke bagian atas tangki. Hal itu membuat perpindahan kalor pada air menjadi lebih cepat. Alat penukar kalor tipe wound serpentine dibuat dari pipa tembaga 3/8 inch dengan panjang 8 m. Tangki penyimpanan mempunyai kapasitas 50 liter air, terbuat dari bahan stainless steel dengan bahan isolasi berupa polyurethane foam dan dilapisi fiber untuk bagian luarnya. Pengujian dilakukan dengan cara memanaskan air di dalam tangki menggunakan alat penukar kalor tipe wound serpentine yang memanfaatkan panas refrigerant keluaran kompresor. Pengujian dilakukan selama dua jam dengan pengambilan data setiap lima menit sekali berdasarkan variasi setting temperatur AC. Parameter yang diukur dalam pengujian ini adalah temperatur air dan refrigerant, tekanan suction dan discharge kompresor, tekanan masukan dan keluaran HE, kecepatan udara keluaran evaporator, kelembaban udara, dan daya listrik yang masuk kompresor. Berdasarkan analisa selama pengujian, dengan AC 1 PK dapat memanaskan 50 liter air hingga temperatur 47.7oC-51.7oC selama 2 jam, efektifitas alat penukar kalor tipe wound serpentine berkisar antara 80.89%-85.96%, dan nilai COP berkisar antara 2.296-3.598. Kesimpulan dari pengujian ini adalah semakin rendah setting temperatur AC, maka temperatur air, efektifitas alat penukar kalor, dan COP sistem S-ACWH akan semakin tinggi. Kata Kunci: S-ACWH, Natural Convection, Wound Serpentine, Pemanas Air,Tangki Air.

Deskripsi Alternatif :

Split Air Conditioning Water Heater (S-ACWH) is a water heating system that is energy efficient because it only utilizes waste heat from the air conditioner. Heat exchanger wound serpentine type is a type that is best used on the S-ACWH system because it uses the principle of natural convection where wound serpentine pipe is placed in the bottom of the water tank so that the heat can be transferred from the bottom of the tank to get to the top of the tank. It makes heat transfer to the water faster. Heat exchanger made of a type of wound serpentine 3/8 inch copper pipe with a length of 8 m. Storage tank has a capacity of 50 liters of water, made of stainless steel with an insulating material such as polyurethane foam and coated fiber to the exterior. Testing is done by heating the water in the tank using a heat exchanger utilizing the type of wound serpentine heat output refrigerant compressor. Tests carried out for two hours with the data retrieval every five minutes once conditioned by variations in temperature setting. The parameters measured in this test is the water and refrigerant temperature, suction and discharge pressure compressor, pressure input and output HE, evaporator exit air velocity, humidity, and power that makes the compressor. Based on the analysis during the test, with AC 1 PK can heat 50 liters of water to a temperature of 47.7oC-51.7oC for 2 hours, the effectiveness of the heat exchanger type of wound serpentine ranged between 80.89% -85.96%, and COP values ranged between 2.296-3.598. The conclusion of this test is the lower the temperature setting air conditioning, the water temperature, the effectiveness of a heat exchanger, and COP system S-ACWH will be higher. Keywords: S-ACWH, Natural Convection, Wound Serpentine, Water Heaters, Water Tank.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakErlin Arvelina
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorerlin.arvelina@polban.ac.id
E-mail CKOerlin.arvelina@polban.ac.id

Print ...

Kontributor...

  • Pembimbing 1: Ir. Conny K. Wachjoe, M.Eng., Ph.D.

    Pembimbing 2: Yanti Suprianti, M.T., Editor: Erlin Arvelina

Download...