Perancangan Helical Baffle Pada High Pressure Heater Di PLTU Bayah Kapasitas 60MW
Design Of A Helical Baffle In High Pressure Heater At Bayah 60MW Steam Generator Power Plant
Skripsi, 030 / 2020 / TPTLUndergraduate Theses from JBPTPPOLBAN / 2022-04-05 12:56:50
Oleh : Naufal Taufiqurrahman - 161724018 (naufalupow98@gmail.com)
Dibuat : 2022-04-05, dengan 4 file
Keyword : heat exchanger, pressure drop, efektivitas, helical baffle, HTRI
Subjek : heat exchanger, pressure drop, effectiviteness, helical baffle, HTRI
High Pressure Heater merupakan salah satu komponen alat penukar panas pada proses Feedwater Heater di Pembangkit Listrik Tenaga Uap, berfungsi sebagai pemanas Feedwater yang memiliki standar operasi 180-190⁰C . High Pressure Heater yang ada di PLTU Bayah menggunakan penukar panas jenis shell and tube dengan segmental baffle. Jenis shell and tube dengan segmental baffle merupakan alat penukar panas konvensional yang banyak digunakan pada Pembangkit Listrik Tenaga Uap. Baffle merupakan sekat yang berfungsi untuk mengatur aliran yang melewati sisi shell dan meningkatkan turbulensi menjadi lebih tinggi. Heat exchanger jenis shell and tube menggunakan helical baffle memiliki beberapa keuntungan dibandingkan dengan segmental baffle, yaitu mengurangi nilai pressure drop, mengurangi masalah fouling factor serta meningkatkan koefisien perpindahan panas hingga 40-50%. Penelitian ini menggunakan metode kuantitatif dengan data primer bersumber dari PLTU Bayah serta data sekunder bersumber dari jurnal dan textbook. Data dianalisa berdasarkan hasil perhitungan manual dan dilakukan perbandingan dengan software Heat Transfer Research Inc (HTRI). Hasil perancangan High Pressure Heater menggunakan helical baffle dengan sudut 3Ë meningkatkan koefisien perpindahan panas dari 57,77 Btu/hrft2°F ke 2316,5954 Btu/hrft2°F mengalami kenaikan sebesar 97%. Nilai faktor kekotoran dari hasil perhitungan perancangan sebesar 0,00163 hft2â°F /Btu sesuai dengan ketentuan nilai yang ada. Perancangan ini meningkatkan efektivitas HPH dari 0,4379 menjadi 0,5967. Kata Kunci: heat exchanger, pressure drop, efektivitas, helical baffle, HTRI.
Deskripsi Alternatif :High Pressure Heater is one of the components of the heat exchanger in the Feedwater Heater process at the Steam Power Plant, functions as a Feedwater heater which has an operating standard of 180-190⁰C . The High Pressure Heater in Bayah's Steam generator Power Plant uses shell and tube type with segmental baffle. The shell and tube's heat exchanger type with segmental baffle is a conventional heat exchanger which is widely used in Steam Power Plants. Baffle is a bulkhead that serves to regulate the flow through the shell side and increase turbulence to be higher. Shell and tube type heat exchangers using helical baffles have several advantages compared to segmental baffles, namely reducing the pressure drop, reducing the fouling factor problem and increasing the heat transfer coefficient up to 40-50%. This study uses a quantitative method with primary data sourced from Bayah's steam generator powerplant and secondary data sourced from journals and textbooks. The data were analyzed based on the results of manual calculations and comparisons were made with Heat Transfer Research Inc (HTRI) software. The results of the High Pressure Heater design using a helical baffle with an angle of 3Ë increase the heat transfer coefficient from 57.77 Btu/hrft2°F to 2316.5954 Btu/hrft2°F, an increase of 97%. The fouling factor value is 0,00163 hft2â°F /Btu in accordance with the standard. This design increases the High Pressure Heater effectiveness from 0.4379 to 0.5967. Keywords: heat exchanger, pressure drop, effectiviteness, helical baffle, HTRI.
Beri Komentar ?#(0) | Bookmark
Properti | Nilai Properti |
---|---|
ID Publisher | JBPTPPOLBAN |
Organisasi | |
Nama Kontak | Erlin Arvelina |
Alamat | Jl. Trsn. Gegerkalong Hilir Ds. Ciwaruga |
Kota | Bandung |
Daerah | Jawa Barat |
Negara | Indonesia |
Telepon | 022 201 3789 ext. 168, 169, 239 |
Fax | 022 201 3889 |
E-mail Administrator | erlin.arvelina@polban.ac.id |
E-mail CKO | erlin.arvelina@polban.ac.id |
Print ...
Kontributor...
- Pembimbing 1: Dra. Tina Mulya Gantina, M.T.
Pembimbing 2: Annisa Syafitri K., S.ST., M.Sc., Editor: Erlin Arvelina
Download...
File : KELENGKAPAN SKRIPSI - 161724018.pdf
(1050637 bytes)
File : BAB 1 - 161724018.pdf
(219574 bytes)
File : BAB 2 - 161724018.pdf
(1007039 bytes)
File : BAB 5 - 161724018.pdf
(150569 bytes)